Atlas Air Compressor Programmable settings, Regulation settings Minimum Nominal Maximum Setting

Page 64

Instruction book

8.15 Programmable settings

8.15.1 Regulation settings

 

 

Minimum

Nominal

Maximum

 

 

setting

setting

setting

 

 

 

 

 

Number of motor starts

starts/day

240

720

720

Minimum stop time 1)

sec

5

5

30

Stop between 2 compressor

sec

2

2

5

modules

 

 

 

 

Start between 2 compressor

sec

2

2

10

modules

 

 

 

 

Power recovery time 3)

sec

10

10

3600

Delay at restarting after

sec

0

0

1200

power recovery 3)

 

 

 

 

 

 

 

 

 

Minimum pressure 2)

 

 

 

 

8 bar Pack

bar(e)

4

7

7.9

8 bar Full-Feature

bar(e)

4

6.8

7.7

10 bar Pack

bar(e)

4

9

9.9

10 bar Full-Feature

bar(e)

4

8.8

9.7

100 psi Pack

bar(e)

4

7

7.9

100 psi Full-Feature

bar(e)

4

6.8

7.7

125 psi Pack

bar(e)

4

8.1

9

125 psi Full-Feature

bar(e)

4

7.75

8.8

145 psi Pack

bar(e)

4

9

9.9

145 psi Full-Feature

bar(e)

4

8.8

9.7

 

 

 

 

 

Maximum pressure 2)

 

 

 

 

8 bar Pack

bar(e)

4.1

8

8

8 bar Full-Feature

bar(e)

4.1

7.8

7.8

10 bar Pack

bar(e)

4.1

10

10

10 bar Full-Feature

bar(e)

4.1

9.8

9.8

100 psi Pack

bar(e)

4.1

8

8

100 psi Full-Feature

bar(e)

4.1

7.8

7.8

125 psi Pack

bar(e)

4.1

9.1

9.1

125 psi Full-Feature

bar(e)

4.1

8.9

8.9

145 psi Pack

bar(e)

4.1

10

10

145 psi Full-Feature

bar(e)

4.1

9.8

9.8

 

 

 

 

 

For Full-Feature also 4)

 

 

 

 

Dewpoint warning

°C

3

15

40

temperature

 

 

 

 

Delay at signal 5)

sec

0

3

10

Delay at starting 6)

sec

0

255

255

2920 1521 00

64

Image 64
Contents Instruction book No 1521 Registration code APC SF / 38Instruction book Skid Tank-mounted Twin Service warning message exists Leading Particulars General descriptionSF4 Skid Control panel Air outlet valve SF4 Tank-mounted SF8FF Multi Details of a compressor module on SF Tank-mounted Air flow Cooling and condensate drain systems FigRegulating system on SF Skid Tank-mounted Twin Protecting the compressorMonitoring components subject to service Regulating system on SF MultiControlling the compressor Automatic restart after voltage failureControl panel Fig Designation FunctionDisplay keys Operating condition of a compressor moduleScroll keys 3-Fig Tabulator key 4-FigSelecting a menu 13 Menu flow, SF MultiElectric cabinet on SF Multi 14 Electric cabinets, SF MultiCompressed air circuit Air dryer on SF Full-Feature FigRefrigerant circuit Installation Dimension drawings Figs .1 up to9820 4054 00/1 Dimension drawing, SF 6-8 Multi Dimension drawing, SF 11-15 Multi Instruction book Installation proposal Fig Instruction book General Electrical connectionsConnections Skid Tank-mounted Twin SF Multi TSHH20 Pictographs PictographsInitial start-up Operating InstructionsStarting During operation Taking out of operation at end of compressor service lifeStopping Maintenance Preventive maintenance schedule for the compressorBefore carrying out any maintenance or repair Service plans on SF MultiMonthly YearlyAdjustments and Servicing Procedures Air filter 1-Figs .7/1.8Belt exchange/tensioning Fig CoolersTesting Safety valveOperating Problem Solving Electric cable size for SF1-8 Principal DataElectric cable size for SF 6-15 Multi Overload relays for SF1-8 Overload relays for SF6-15 MultiMain fuses for SF1-8 Main fuses for SF6-15 MultiReference conditions/limitations Reference conditionsSF1-4 8bar 50 Hz SF2-4 10 bar 50 Hz10 SF1-4 100 psi 60 Hz 11 SF2-4 145 psi 60 Hz13 SF6-15 Multi 10 bar 50 Hz 12 SF6-15 Multi 8 bar 50 Hz14 SF6-15 Multi 100 psi 60 Hz 15 SF6-15 Multi 125 psi 60 Hz 16 SF6-15 Multi 145 psi 60 HzSF11 SF15 125 psi SF11 SF15 145 psiRegulator Functions for SF Multi Menu-driven control programsFunction of control programs Program/Function Description Main screenLine Indicates Remarks Element status screen, typical exampleQuick look at actual compressor status ProcedureCalling up other menus No message exists Status data menuShut-down message exists Shut-down reset Service warning message exists Measured data menuCounters menu Test menuModify parameters menu Modifying parametersModifying the pressure bands Modifying protection settings Checking protections for compressor modulesModifying service plans Service plansResulting service actions to be carried out Programmed service plan intervals Service plans IntervalsService actions according to Programming start/stop/pressure band commands Programming Clock functionInstruction book To activate/deactivate the timer To modify a commandInstruction book Adding a command between two existing commands To delete commandsConfiguration menu Deleting all commandsDeleting all commands related to a specific day Deleting a specific start/stop/pressure band commandService menu Service plans ABI Saved data menu Programmable settings Regulation settings Minimum Nominal Maximum SettingService settings Minimum Nominal Maximum Setting Conversion List of SI Units Into US/BRITISH UnitsPart number Description PED Class Components subject to 97/23/EC Pressure Equipment DirectiveOverall Rating Instruction book Instruction book Wnership Data Safety Preca Utions