Atlas Air Compressor manual Shut-down reset

Page 46

Instruction book

2.It remains possible to scroll through other menus, e.g. to check the values of other parameters. When returning to the Status data menu, the option "Shutdowns" will blink. This option can be selected by pressing the tabulator key (5) to return to the shut-down screen (Fig. 8.6).

Shut-down reset

1.Switch off the voltage, depressurize the compressor and remedy the trouble. After remedying, switch on the voltage and press the key "Reset" (F3).

2.Press the keys "Menu" and "Mainscreen" to return to the Main screen and restart the compressor by means of button I.

8.3.3 A warning message exists

1.If a shut-down warning exists, LED (7) is alight. The Main screen will change into a screen similar to the one below:

Compressor Outlet

 

 

7.0 bar

**

 

Warning

**↓

Menu

***

***

* - - -

F1

 

F2

F3

Fig. 8.7 Example of a warning screen

2.The indicators (***) are blinking and the message **Warning** appears alternately with the messages indicating whether the compressor is in operation or not (Compressor Running or Compressor Off).

3.Press the key "Menu" (F1) and the tabulator key (5) to select the Status Data menu, the option "Protection" is blinking.

4.Scroll to this option and select it by pressing the tabulator key (5): option "Warnings" blinks. Scroll to this option and select it by pressing the tabulator key (5). A screen similar to the one in Fig. 8.8 appears:

Element 1

 

80 °C

Warning

Maximum

75 °C

Menu

***

***

F1

F2

F3

Fig. 8.8 Example of a warning screen

The screen shows that the temperature at the outlet of element 1 (80 °C) is too high.

5.Stop the compressor by means of button O and wait until the compressor has stopped.

6.Switch off the voltage, inspect the compressor and remedy.

7.The warning message will disappear automatically as soon as the warning condition disappears.

2920 1521 00

46

Image 46
Contents Instruction book No 1521 Registration code APC SF / 38Instruction book Skid Tank-mounted Twin Service warning message exists Leading Particulars General descriptionSF4 Skid Control panel Air outlet valve SF4 Tank-mounted SF8FF Multi Details of a compressor module on SF Tank-mounted Air flow Cooling and condensate drain systems FigRegulating system on SF Skid Tank-mounted Twin Protecting the compressorControlling the compressor Monitoring components subject to serviceRegulating system on SF Multi Automatic restart after voltage failureControl panel Fig Designation FunctionScroll keys 3-Fig Display keysOperating condition of a compressor module Tabulator key 4-FigSelecting a menu 13 Menu flow, SF MultiElectric cabinet on SF Multi 14 Electric cabinets, SF MultiCompressed air circuit Air dryer on SF Full-Feature FigRefrigerant circuit Installation Dimension drawings Figs .1 up to9820 4054 00/1 Dimension drawing, SF 6-8 Multi Dimension drawing, SF 11-15 Multi Instruction book Installation proposal Fig Instruction book General Electrical connectionsConnections Skid Tank-mounted Twin SF Multi TSHH20 Pictographs PictographsInitial start-up Operating InstructionsStarting During operation Taking out of operation at end of compressor service lifeStopping Before carrying out any maintenance or repair MaintenancePreventive maintenance schedule for the compressor Service plans on SF MultiMonthly YearlyBelt exchange/tensioning Fig Adjustments and Servicing ProceduresAir filter 1-Figs .7/1.8 CoolersTesting Safety valveOperating Problem Solving Electric cable size for SF1-8 Principal DataElectric cable size for SF 6-15 Multi Overload relays for SF1-8 Overload relays for SF6-15 MultiReference conditions/limitations Main fuses for SF1-8Main fuses for SF6-15 Multi Reference conditions10 SF1-4 100 psi 60 Hz SF1-4 8bar 50 HzSF2-4 10 bar 50 Hz 11 SF2-4 145 psi 60 Hz13 SF6-15 Multi 10 bar 50 Hz 12 SF6-15 Multi 8 bar 50 Hz14 SF6-15 Multi 100 psi 60 Hz SF11 SF15 125 psi 15 SF6-15 Multi 125 psi 60 Hz16 SF6-15 Multi 145 psi 60 Hz SF11 SF15 145 psiRegulator Functions for SF Multi Menu-driven control programsFunction of control programs Program/Function Description Main screenLine Indicates Remarks Element status screen, typical exampleQuick look at actual compressor status ProcedureCalling up other menus No message exists Status data menuShut-down message exists Shut-down reset Service warning message exists Measured data menuCounters menu Test menuModify parameters menu Modifying parametersModifying the pressure bands Modifying protection settings Checking protections for compressor modulesModifying service plans Service plansResulting service actions to be carried out Programmed service plan intervals Service plans IntervalsService actions according to Programming start/stop/pressure band commands Programming Clock functionInstruction book To activate/deactivate the timer To modify a commandInstruction book Adding a command between two existing commands To delete commandsDeleting all commands related to a specific day Configuration menuDeleting all commands Deleting a specific start/stop/pressure band commandService menu Service plans ABI Saved data menu Programmable settings Regulation settings Minimum Nominal Maximum SettingService settings Minimum Nominal Maximum Setting Conversion List of SI Units Into US/BRITISH UnitsPart number Description PED Class Components subject to 97/23/EC Pressure Equipment DirectiveOverall Rating Instruction book Instruction book Wnership Data Safety Preca Utions