Shindaiwa 4 Cycle Diesel Engine Checking Fuel, Engine Oil and Water Leakage, Checking Battery

Page 15

6-4 Checking Fuel, Engine Oil and Water Leakage

Caution : Fire

zAlways wipe any drip of Diesel fuel or oil. Do not use this equipment when a leak is found.

Repair the equipment before use.

Be sure to check for any fuel leak at the hose connection, and oil and coolant/water by opening side doors. When checking for any fuel leak, open a fuel lever and be sure to close the fuel lever after checking.

6-5 Checking Battery

Caution : Injuries to eyes and skin

zBattery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin or clothing. If the acid comes in contact, especially with eyes, flush with a lot of water, and contact your physician immediately.

Caution : Explosion

zWhen the liquid level is below the LOWER level, never use the equipment nor recharge the battery.

zBattery may emit some combustible gas, so keep it away from fire and sparks.

Check the fluid level. If the level is near or lower than the

TERMINAL

 

LOWER level, add distilled water until the fluid level reaches

 

 

the UPPER level.

 

Make sure that the battery cables are firmly secured to the

UPPER

LEVEL

 

posts. Tighten the clamps if necessary.

LOWER

 

LEVEL

<Caution>

zCheck the hydrometer of the battery fluid. If it falls below 1.23, the battery requires recharg- ing. Please consult with our authorized distributor or our engineering section.

„ Replacing battery

INS-CAP

- TERMINAL

 

+ TERMINAL

Remove the clamp and cable from negative (-) post in the battery. (Remove always negative side first)

Remove the hold-down clamp from the battery.

Remove the clamp and cable from positive (+) post in

HOLD-DOWN

 

the battery.

CLAMP

 

 

Remove the battery from the seat.

BATTERY

 

Reinstall a new battery in the reverse order. (Install always the cable to the positive (+) post in the new battery first.)

<Caution>

zUse the following battery. 46B24L

7.Operation

7-1 Initializing/Preparation

14

Image 15
Contents DGW311DM DGW311L Introduction Safety Guidelines Page DGW311DM DGW311L DGW311DM DGW311L SpecificationsParts UseEquipment ECO Welding DGW311DM only Monitor Lamp Earth Leakage Breaker Earth Grounding Terminal Bonnet Grounding Grounding ROD Slow-Down Feature Initialization and Pre-checkChecking Engine Oil Checking Coolant/Water SAE10W/30Checking Fuel Lowest Ambient Temperature Mixture Ratio 30% 35% 45%Checking Battery Checking Fuel, Engine Oil and Water LeakageOperation Initializing/Preparation ⑧ Keep the engine idle for about 5 minutes Ishes„ Restart after stopping due to fuel shortage Stopping Generator/WelderWelding Operation Selection Welding Cable Polarity Connection Welding CableECO Single Dual Welding Rod Φ2.0 φ4.0 Φ2.6 φ6.0 Welding Duty Cycle『DUAL 』 35-280A45-310A φ2.0-φ6.0Maximum output from the terminals U, V, W is 10kVA 380V 400V 415V 380V 400V 415V 2.2 1-Phase Output TerminalsOutput Limitation Operation Simultaneous Use of Welding and Generating Checking and Maintenance 50hrs Clean/Change Fuel FilterAdjust Tension V-Belt Adjust Engine Valve ClearanceTurn the fuel line valve lever to 『CLOSE』 Unscrew the retaining ring by turning counterclockwise,Remove the cup and fuel filter element Long Term Storage Excessive Welding Arc TroubleshootingInsufficient Fuel Water or contaminants in fuelEngine does not stop Stop Solenoid disorder No AC outputAC Output is Weak Slow-Down does not activateDGW311L DGW311DM Engine Wiring DiagramGenerator Wiring Diagram DGW311L W220B DGW311L W380A DGW311L W400A DGW311L W415A Telephone 81-82-849-2220 FAX