Caution : Damage to the equipment or other properties

zIn the event using the equipment to computers, microcomputers incorporated loads and pre-

cision equipment, there is a possibility for them to be mal-functioned or broken down. <Caution>

zBe sure to use the power cord with crimping terminal to connect to output terminals.

zVolt meter reads the 3-Phase figures, even if the circuit breaker is positioned toOFF, when

the engine is driving.

After the engine starts (Refer to7-1 Initializing/Preparation』), operate the equipment as per the following procedures.

Turn off the power switch in the load, and then turn the circuit breaker to OFF.

Connect the load to the output terminals or receptacles.

Close the output terminal cover, after finishing connections and fix the cover with bolts. Turn the circuit breaker to ON.

When finishing the load operation, always turn the circuit breaker toOFF』.

„The Circuit Breaker

Caution : Injuries

z Be sure to turn off the power switch in the load when turning the circuit breaker to ON, when the circuit breaker has activated.

When the electric supply exceeds the rated output (overload), the circuit breaker activates to trip off in order to shut off the circuit. When the load in operation stops, check the breaker. When the circuit breaker is positioned intermediaryONandOFF, check if the earth leakage indication lamp turns ON or not. In the case the lamp turning ON, refer to 5-3 Earth Leakage Breaker. In the case the lamp NOT turning ON, follow the next procedures to restore the circuit breaker.

Turn off all the power switches in the loads.

Turn (Push) down the circuit breaker toOFFonce and then turn (push) up the circuit breaker toON』.

<Caution>

zTake care for overload, referring to 9-2 Output Limitation』.

zWhen the output selector switch is positioned to ECO and AC power is used, the circuit breaker trips off to shut down the circuit. Stop using AC power and follow the above proce- dures to restore the circuit breaker. (DGW311DM only)

10.Simultaneous Use of Welding and Generating

The circuit breaker reacts on the AC power supply circuit only. In the simultaneous use of welding and generating, there sometimes happens overload to the engine.

Refer to the following table and limit the AC power use.

DGW311DM-(W)220B, DGW311L-(W)220B :

Limitation of AC Power Supply in the simultaneous use of welding and generating (60Hz)

23

Image 24
Contents DGW311DM DGW311L Introduction Safety Guidelines Page DGW311DM DGW311L Specifications DGW311DM DGW311LUse PartsEquipment ECO Welding DGW311DM only Monitor Lamp Earth Leakage Breaker Earth Grounding Terminal Bonnet Grounding Grounding ROD Slow-Down Feature Initialization and Pre-checkChecking Engine Oil SAE10W/30 Checking Coolant/WaterLowest Ambient Temperature Mixture Ratio 30% 35% 45% Checking FuelChecking Battery Checking Fuel, Engine Oil and Water LeakageOperation Initializing/Preparation Ishes ⑧ Keep the engine idle for about 5 minutes„ Restart after stopping due to fuel shortage Stopping Generator/WelderWelding Operation Selection Welding Cable Polarity Connection Welding CableECO Single Dual Welding Rod Φ2.0 φ4.0 Φ2.6 φ6.0 Duty Cycle Welding『DUAL 』 35-280A45-310A φ2.0-φ6.0Maximum output from the terminals U, V, W is 10kVA 380V 400V 415V 2.2 1-Phase Output Terminals 380V 400V 415VOutput Limitation Operation Simultaneous Use of Welding and Generating Checking and Maintenance Clean/Change Fuel Filter Adjust Tension V-BeltAdjust Engine Valve Clearance 50hrsTurn the fuel line valve lever to 『CLOSE』 Unscrew the retaining ring by turning counterclockwise,Remove the cup and fuel filter element Long Term Storage Troubleshooting Insufficient FuelWater or contaminants in fuel Excessive Welding ArcNo AC output AC Output is WeakSlow-Down does not activate Engine does not stop Stop Solenoid disorderEngine Wiring Diagram DGW311L DGW311DMGenerator Wiring Diagram DGW311L W220B DGW311L W380A DGW311L W400A DGW311L W415A Telephone 81-82-849-2220 FAX