„Restart after stopping due to fuel shortage

This equipment is equipped with automatic air vacuuming feature. Therefore, even though the engine stops due to running out of fuel, you can restart the engine easily by the following steps.

Turn the starter switch to STOP.

Fill the fuel.

Turn the Slow-Down switch to ON.

Turn the starter switch to RUN.

Turn the starter switch to START and drive the starter motor. <Caution>

z Do not drive the starter motor for more than 15 seconds successively. z If you need restart, wait for 30 seconds or more before retry.

Release the starter switch, as soon as the engine started. <Caution>

z Once the engine is started, do not turn the starter switch to START.

Wait for about 1 minute to vacuum the air out.

(The engine speed becomes stable when the air is extracted.) <Caution>

z Keep the Slow-Down switch ON unit the air is completely extracted out (unit the engine speed becomes stable), otherwise the engine may disorder.

7-2 Stopping Generator/Welder

Turn (Push down) the breaker to OFF.

Turn the Slow-Down switch to ON.

Keep the engine idle (cooling down) for about 5 minutes.

Turn the starter switch to STOP.

After the engine stops, turn the fuel lever to CLOSE. <Caution>

z When the engine does not stop in spite of turning the starter switch to STOP, turn the fuel lever to CLOSE, then the engine will stop in a few minutes.

In this case, consult with our authorized distributor or our engineering section and ask to re- pair.

8.Welding Operation

8-1 Selection – Welding Cable

Select the cable with proper gauge, based on the allowable amperage and distance per the table shown below.

The welding capacity is reduced if the small gauge cable is used. <Caution>

zWelding cables should be used unstrained.

zWhen the welding cables are used in swirl, the welding capacity is reduced.

16

Image 17
Contents DGW311DM DGW311L Introduction Safety Guidelines Page DGW311DM DGW311L DGW311DM DGW311L SpecificationsParts UseEquipment ECO Welding DGW311DM only Monitor Lamp Earth Leakage Breaker Earth Grounding Terminal Bonnet Grounding Grounding ROD Checking Engine Oil Slow-Down FeatureInitialization and Pre-check Checking Coolant/Water SAE10W/30 Checking Fuel Lowest Ambient Temperature Mixture Ratio 30% 35% 45%Operation Initializing/Preparation Checking BatteryChecking Fuel, Engine Oil and Water Leakage ⑧ Keep the engine idle for about 5 minutes IshesWelding Operation Selection Welding Cable „ Restart after stopping due to fuel shortageStopping Generator/Welder ECO Single Dual Welding Rod Φ2.0 φ4.0 Φ2.6 φ6.0 PolarityConnection Welding Cable Welding Duty CycleMaximum output from the terminals U, V, W is 10kVA 『DUAL 』35-280A45-310A φ2.0-φ6.0 380V 400V 415V 380V 400V 415V 2.2 1-Phase Output TerminalsOutput Limitation Operation Simultaneous Use of Welding and Generating Checking and Maintenance Adjust Tension V-Belt Clean/Change Fuel FilterAdjust Engine Valve Clearance 50hrsRemove the cup and fuel filter element Turn the fuel line valve lever to 『CLOSE』Unscrew the retaining ring by turning counterclockwise, Long Term Storage Insufficient Fuel TroubleshootingWater or contaminants in fuel Excessive Welding ArcAC Output is Weak No AC outputSlow-Down does not activate Engine does not stop Stop Solenoid disorderDGW311L DGW311DM Engine Wiring DiagramGenerator Wiring Diagram DGW311L W220B DGW311L W380A DGW311L W400A DGW311L W415A Telephone 81-82-849-2220 FAX