Welding Output | AC Power Output |
|
|
|
|
Welding Rod/Current | ||
|
|
|
φ2.0mm/50A or below | 9.5kVA or below | 7.6kVA or below |
|
|
|
φ2.6mm/80A | 8.6kVA or below | 6.8kVA or below |
|
|
|
φ3.2mm/120A | 7.2kVA or below | 5.7kVA or below |
|
|
|
φ4.0mm (φ2.0mmx2)/170A | 5.2kVA or below | 4.1kVA or below |
|
|
|
φ5.0mm (φ2.6mmx2)/220A | 3.0kVA or below | 2.4kVA or below |
|
|
|
φ6.0mm (φ3.2mmx2)/280A | 0kVA or below | 0kVA or below |
※ ( ) indicates
zThe simultaneous use of ECO welding and AC power is not available. (DGW311DM only)
Limitation of AC Power Supply in the simultaneous use of welding and generating (50Hz)
Welding Output | AC Power Output |
|
|
|
|
Welding Rod/Current | ||
|
|
|
φ2.0mm/50A or below | 8.5kVA or below | 6.8kVA or below |
|
|
|
φ2.6mm/80A | 7.6kVA or below | 6.0kVA or below |
|
|
|
φ3.2mm/120A | 6.2kVA or below | 4.9kVA or below |
|
|
|
φ4.0mm/170A | 4.2kVA or below | 3.3kVA or below |
|
|
|
φ5.0mm/220A | 2.0kVA or below | 1.6kVA or below |
|
|
|
φ6.0mm/260A | 0kVA or below | 0kVA or below |
11. Checking and Maintenance
Danger : Electric Shock・Injuries
zBefore performing any equipment check or maintenance, stop the engine, and remove en- gine key. A person performing the maintenance should always keep the key.
Caution : Fire・Burns
zWhen checking the engine, always stop the engine, and keep away from fire. Wait until the
engine cools down, before performing any checks.
To optimize the use of this equipment, we recommend the periodical equipment checks and maintenance based on the following matrix.
<Caution>
zThe authorized technicians should perform all checking and maintenance work, except for the
zRequest for the maintenance item with ● mark to the authorized distributor or our engi- neering section.
zThis table only covers the simple checks and maintenance for the engine. For more detailed guide, please refer to the User’s Manual for the engine.
zAlways use our genuine replacement parts.