Danger : Suffocation from exhaust fume
zExhaust fume from the engine contains many elements harmful to human. Do not operate this equipment in poorly ventilated area, such as inside a room or in a tunnel.
Caution : Suffocation from exhaust fume
zDo not point the exhaust fume toward pedestrians or building.
Caution : Fire
zTemperature around muffler and exhaust can get extremely high. Keep any inflammable items (such as fuel, gas, paint, etc.) away from the equipment.
zAlways operate this equipment on flat surface and, at least 1 meter away from any objects (wall, box, etc.)
Caution : Injuries
zAlways place the equipment on flat and stable surface, to keep the equipment from sliding. Be sure to lock the wheels for the wheeled models.
zWhen starting the engine, turn off the connected equipment and set the circuit breaker to OFF position.
①Turn the circuit breaker to OFF position.
② Turn the fuel lever to OPEN.
③ Turn the
④When the temperature is below 5℃,turn the starter switch to PREHEAT. The preheating lamp flashes 15
seconds. The lamp comes off when the PREHEAT fin-
CLOSE
ishes.
OPEN
⑤Turn the starter switch to START to start the engine by the starter motor.
<Caution>
zDo not drive the starter motor for more than 15 seconds successively.
zIf you need to restart, wait for 30 seconds or more before retry.
⑥Release the starter switch, as soon as the engine is started. <Caution>
z Once the engine is started, do not turn the starter switch to START. ⑦ Make sure the frequency to the monitor on the control panel.
⑧ Keep the engine idle for about 5 minutes.
DGW311DM
DGW311L
| STARTER SWITCH |
| CIRCUIT BREAKER | STARTER SWITCH | ||
CIRCUIT BREAKER |
|
| ||||
|
|
|
| |||
PREHEAT LAMP |
| PREHEAT LAMP | ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
15