Shindaiwa 4 Cycle Diesel Engine specifications Monitor Lamp

Page 9
OIL PRESSURE MONITOR LAMP
BATTERY CHARGE MONITOR LAMP
COOLANT/WATER TEMPERATURE MONITOR LAMP

<Caution>

zWhen welding is performed, do not turn the output selector switch, which causes the burnout of the switch.

zECO is designed for welding only. The circuit breaker trips when ECO is used for AC power supply.

5-2 Monitor Lamp

The equipment is equipped with monitoring function of oil pressure, battery charge and water/coolant Temperature. When it is started by the starter switch from STOP to RUN under normal condition, Oil Pressure and Battery lamps will flash, and then the lamps will go off, immediately after the engine starts.

When abnormality is detected either in water temperature or in oil pressure, the corresponding monitor lamp will flash, and the automatic shutoff shall be engaged to the engine.

When the automatic shutoff is engaged, turn the starter switch to STOP position, and then restart the engine. In the event the automatic shutoff is engaged next time, check all parts of the corresponding alarm.

5-2.1 Oil Pressure Monitor Lamp

Danger : Injuries

zClose all doors and place locks during operating this equipment, to avoid injuries by uninten- tionally touching cooling fan and fan belt.

Caution : Burns

zDo not touch the engine and muffler during operation and immediately after stopping the equipment, for the temperature can reach extremely high.

zWhen checking engine oil, always stop the engine, and wait until the engine cools down. If

you open either the oil gauge or the oil filter cap during operation, hot oil may cause some injury.

When the engine oil pressure drops during operation, the oil pressure monitor lamp will flash, and the automatic shutoff will be engaged.

When this occurs, check the engine oil level, and replenish to the maximum level if needed. <Caution>

zThe engine oil pressure monitor cannot detect the degradation of engine oil itself. Please check the engine oil periodically, and change if needed. (Refer to No. 11. Maintenance.)

5-2.2 Battery Charge Monitor Lamp

When the battery is unable to be charged during operation, the battery charge monitor lamp will flash and the automatic shutoff will be engaged. In the event it will happen, consult with the au- thorized distributor or our engineering section.

<Caution>

zThe battery charge monitor cannot detect the degradation of battery life nor the battery fluid

8

Image 9
Contents DGW311DM DGW311L Introduction Safety Guidelines Page DGW311DM DGW311L DGW311DM DGW311L SpecificationsParts UseEquipment ECO Welding DGW311DM only Monitor Lamp Earth Leakage Breaker Earth Grounding Terminal Bonnet Grounding Grounding ROD Slow-Down Feature Initialization and Pre-checkChecking Engine Oil Checking Coolant/Water SAE10W/30Checking Fuel Lowest Ambient Temperature Mixture Ratio 30% 35% 45%Checking Battery Checking Fuel, Engine Oil and Water LeakageOperation Initializing/Preparation ⑧ Keep the engine idle for about 5 minutes Ishes„ Restart after stopping due to fuel shortage Stopping Generator/WelderWelding Operation Selection Welding Cable Polarity Connection Welding CableECO Single Dual Welding Rod Φ2.0 φ4.0 Φ2.6 φ6.0 Welding Duty Cycle『DUAL 』 35-280A45-310A φ2.0-φ6.0Maximum output from the terminals U, V, W is 10kVA 380V 400V 415V 380V 400V 415V 2.2 1-Phase Output TerminalsOutput Limitation Operation Simultaneous Use of Welding and Generating Checking and Maintenance Adjust Tension V-Belt Clean/Change Fuel FilterAdjust Engine Valve Clearance 50hrsTurn the fuel line valve lever to 『CLOSE』 Unscrew the retaining ring by turning counterclockwise,Remove the cup and fuel filter element Long Term Storage Insufficient Fuel TroubleshootingWater or contaminants in fuel Excessive Welding ArcAC Output is Weak No AC outputSlow-Down does not activate Engine does not stop Stop Solenoid disorderDGW311L DGW311DM Engine Wiring DiagramGenerator Wiring Diagram DGW311L W220B DGW311L W380A DGW311L W400A DGW311L W415A Telephone 81-82-849-2220 FAX