<Caution>
zWhen welding is performed, do not turn the output selector switch, which causes the burnout of the switch.
zECO is designed for welding only. The circuit breaker trips when ECO is used for AC power supply.
5-2 Monitor Lamp
The equipment is equipped with monitoring function of oil pressure, battery charge and water/coolant Temperature. When it is started by the starter switch from STOP to RUN under normal condition, Oil Pressure and Battery lamps will flash, and then the lamps will go off, immediately after the engine starts.
When abnormality is detected either in water temperature or in oil pressure, the corresponding monitor lamp will flash, and the automatic shutoff shall be engaged to the engine.
When the automatic shutoff is engaged, turn the starter switch to STOP position, and then restart the engine. In the event the automatic shutoff is engaged next time, check all parts of the corresponding alarm.
Danger : Injuries
zClose all doors and place locks during operating this equipment, to avoid injuries by uninten- tionally touching cooling fan and fan belt.
Caution : Burns
zDo not touch the engine and muffler during operation and immediately after stopping the equipment, for the temperature can reach extremely high.
zWhen checking engine oil, always stop the engine, and wait until the engine cools down. If
you open either the oil gauge or the oil filter cap during operation, hot oil may cause some injury.
When the engine oil pressure drops during operation, the oil pressure monitor lamp will flash, and the automatic shutoff will be engaged.
When this occurs, check the engine oil level, and replenish to the maximum level if needed. <Caution>
zThe engine oil pressure monitor cannot detect the degradation of engine oil itself. Please check the engine oil periodically, and change if needed. (Refer to No. 11. Maintenance.)
When the battery is unable to be charged during operation, the battery charge monitor lamp will flash and the automatic shutoff will be engaged. In the event it will happen, consult with the au- thorized distributor or our engineering section.
<Caution>
zThe battery charge monitor cannot detect the degradation of battery life nor the battery fluid
8