Graco Inc 222700, 3500WB, 308584 manual Equipment Misuse Hazard, Toxic Fluid Hazard

Page 5
EQUIPMENT MISUSE HAZARD

TOXIC FLUID HAZARD WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury.

DThis equipment is for professional use only.

DRead all the instruction manuals, tags, and labels before operating the equipment.

DUse the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.

DDo not alter or modify this equipment. Use only genuine Graco parts and accessories.

DCheck the equipment daily. Repair or replace worn or damaged parts immediately.

DDo not exceed the maximum working pressure of the lowest rated system component. This equip- ment has a 100 psi (0.7 MPa, 7 bar) maximum working air and fluid pressure.

DUse fluids that are compatible with the equipment wetted parts. See the Technical Data section of all the equipment manuals. Read the fluid manufacturer’s warnings.

DRoute the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180_F (82_C) or below –40_F (–40_C).

DDo not use the hoses to pull equipment.

DWear hearing protection when operating this equipment.

DComply with all applicable local, state, and national fire, electrical, and other safety regulations.

TOXIC FLUID HAZARD

Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled.

DKnow the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.

DStore hazardous fluid in an approved container. Dispose of the hazardous fluid according to all local, state, and national guidelines.

DWear appropriate protective clothing, gloves, eyewear, and respirator.

308584 5

Image 5
Contents 308584 INSTRUCTIONS-PARTS LIST100 psi 0.7 MPa, 7 bar Maximum Working Pressure Part No. 222700, Series CSymbols Table of ContentsWarning Symbol Caution SymbolELECTRIC SHOCK HAZARD Warnings are continued on the next page FIRE AND EXPLOSION HAZARDPRESSURIZED EQUIPMENT HAZARD TOXIC FLUID HAZARD EQUIPMENT MISUSE HAZARDSpraying Waterborne Fluids Electrostatically IntroductionOperating the Electrostatics Refer to Fig. 1, pageB A C D Inner Hose Layer EE is a PTFE tube Graco Waterborne Fluid Hose purchased separatelyD Conductive Hose Layer DD covers the PTFE tube H2O PRO Voltage Block connection shownInstalling the System InstallationVentilate the Spray Booth Warning SignsPRO 3500wb Gun shown with the Graco H2O PRO Batch System Consult your isolation system manual for other configurationsT S N K L M G F NH R B A E D P CInstall the Fluid LIne Accessories Install the Air Line AccessoriesConnect the Air Line Connect the Exhaust TubeContinued on the next page Filter the FluidConnect the Fluid Hose connection shown Connect the Fluid Hose continuedH2O PRO Voltage Block FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Ground the SystemCheck the Electrical Grounding Operation Fluid Voltage Discharge and Grounding ProcedurePressure Relief Procedure Selecting a Fluid Nozzle and Air Cap Operating ChecklistCOMPONENT RUPTURE HAZARD Operating the Spray GunFIRE AND EXPLOSION HAZARD Fine Adjustments of the Spray Gun Atomizing Air Valve AdjustmentShutdown MaintenanceDaily Care and Cleaning Procedure Clean the Air Cap and Fluid NozzleFlush the Spray Gun Equipment neededVoltage Loss Troubleshooting TroubleshootingSpray Gun Waterborne Fluid HoseTests Voltage Loss Troubleshooting continuedProblem Electrical TroubleshootingSolution CauseSpray Pattern Troubleshooting Gun Operation Troubleshooting Poor Electrostatic Wrap TroubleshootingGun Operation Troubleshooting continued Test Gun Resistance Electrical TestsTest Resistor Stud Resistance Test Power Supply ResistancePrepare the Gun for Service ServiceAir Cap/Nozzle/Resistor Stud Replacement Tools Included with the GunInstallation Air Cap/Nozzle/Resistor Stud Replacement continuedElectrode Needle Replacement If installing the complete fluid rod assembly, go to step 11, page Preventative MaintenanceFluid Packing Rod Removal and Repair WhereFluid Packing Rod Removal and Repair continued Fluid Adjustment Assembly Repair Fan Air Adjustment Valve RepairIf installing the complete valve, go to step DETAIL Apply a very light coat of lubricant to the o-rings 41 Fluid Adjustment Assembly Repair continuedAir Trigger Valve Repair Atomizing Air Valve Repair 05363B ES ON-OFF Valve RepairMOVING PARTS HAZARD Barrel Removal  Do not expose the gasket 18a to solvents Power Supply Replacement Apply a very light coat of lubricant to the o-rings 37a 05158B Turbine Alternator ReplacementBarrel Installation Measurements, inches mm Graco Waterborne Fluid Hose RepairPRO 3500sc Gun Conversion PRO 3500SC Gun DisassemblyNOTE Keep all the following parts for reassembly Installing the Fluid Needle Assembly 10. Tighten the nut 78* onto the ferrule housing See Detail A Spray Gun PartsPart No. 222700, Series C Model PRO 3500wb Spray Gun EQUIPMENT MISUSE HAZARDY Replacement Warning signs are available at no cost DescriptionUse Only Genuine Graco Parts and Accessories AccessoriesWaterborne Fluid Hose Assembly 100 psi 0.7 MPa, 7 bar Maximum Working PressureManual Change Summary For use in the Fluid Voltage Discharge and Ground- ing ProcedureSnap Ring Pliers Gun High Voltage Probe & MeterPage Data Technical DataCategory Graco Phone Number The Graco Warranty and DisclaimersWARRANTY EQUIPMENT NOT COVERED BY GRACO WARRANTY