Carrier
48HJD005-007
specifications
Typical Wiring Schematic and Component Arrangement
Troubleshooting
Relief Damper Characteristics
Install
Wiring Harness
Spark Gap Adjustment
Single-Phase Units
Service
Page 44
44
Fig. 55 — Typical Wiring Schematic and Component Arrangement
(208/230
3-Phase
Unit Shown)
Page 43
Page 45
Image 44
Page 43
Page 45
Contents
CONTENTS
SAFETY CONSIDERATIONS
INSTALLATION
Step 1 - Provide Unit Support
Fig. 1 - Roof Curb Details
1′-4″
Fig. 2 - Unit Leveling Tolerances
Fig. 3 - Condensate Drain Pan
Step 7 - Make Electrical Connections
Table 1 - Physical Data
Table 1 - Physical Data cont
3/4″
Fig. 5 - Base Unit Dimensions - 48HJ004-007
1/2″
Step 8 - Adjust Factory-Installed Options
Fig. 7 - Gas Piping Guide With Accessory
Thru-the-Curb Service Connections
Fig. 6 - Flue Hood Details
Fig. 9 - Low-Voltage Connections With or Without Economizer
Fig. 8 - Power Wiring Connections
Fig. 10 - Field Control Wiring Raceway
the percent of voltage imbalance
Never operate a motor where a phase imbalance in supply volt
age is greater than 2%. Use the following formula to determine
Table 2C - 48HJ High-Static Motor Units Without Electrical Convenience Outlet
Fig. 11 - Accessory Field-Installed Humidistat
208/230-V Unit Shown
Fig. 13 - Typical Access Panel Locations
Fig. 15 - Durablade Economizer Installed in Unit
Fig. 16 - Horizontal Durablade Economizer Installation
Fig. 14 - Outdoor-Air Hood Details
Wiring Harness
Fig. 19A - Durablade Economizer Damper Minimum Position Setting
Fig. 19B - Durablade Economizer Minimum Position Damper Setting
Fig. 20 - Outdoor-Air Thermostat Enthalpy Control Installation
Relief Damper Characteristics
Fig. 24 - Typical Access Panel Locations
Fig. 25 - Exhaust Air Hood Assembly
Fig. 22 - Durablade Economizer Barometric
Fig. 28 - Rear EconoMi$er Flange Installation
Fig. 26 - Outdoor-Air Hood Assembly
Fig. 27 - Completed Hood Assembly
Fig. 29 - EconoMi$er Installed
Fig. 31 - EconoMi$er Sensor Wiring
Fig. 33 - Typical Access Panel Locations
Fig. 32 - Wiring Diagram for Power Exhaust System
POWER EXHAUST SYSTEM HIGH VOLTAGE
Fig. 34 - Supply-Air Sensor Placement
Table 4 - Default Potentiometer Settings
Fig. 35 - EconoMi$er Control Adjustment
Potentiometers Factory Settings
Fig. 37 - Belt-Drive Motor Mounting
Step 9 - Adjust Evaporator-Fan Speed - Ad
Fig. 38 - Evaporator-Fan Pulley Adjustment
Table 7 - Evaporator-Fan Motor Data - High-Static Motors
Table 5A - 48HJ Fan Rpm at Motor Pulley Setting With Standard Motor
Table 6 - Evaporator-Fan Motor Data - Standard Motor
Bels
Table 8 - Motor Nominal Horsepower
Table 9 - Outdoor Sound Power Total Unit
Table 12 - 48HJ005 Fan Performance - Vertical Discharge Units With Standard Motor
Single-Phase Units
3-Phase Units
Table 16 - 48HJ007 Fan Performance - Vertical Discharge Units With Standard Motor
Table 18 - 48HJ004 Fan Performance - Horizontal Discharge Units With Standard Motor
Table 20 - 48HJ005 Fan Performance - Horizontal Discharge Units With Standard Motor
3-Phase Units
FIOP - Factory-Installed Option
Table 26 - Economizer Static Pressure Drop in. wg
Table 27 - FIOP MoistureMiser Dehumidification
Package Static Pressure Drop in. wg
PRE-START-UP
START-UP
Table 28 - Altitude Compensation
Heating
Operating Sequence
When the supply-air temperature falls between 57 F and
Fig. 39 - MoistureMiser Option Operation
SERVICE
Lubrication
Fig. 40 - Cleaning Condenser Coil Fig. 41 - Propping Up Top Panel
Fig. 42 - Separating Coil Sections
Fig. 45 - Cooling Charging Chart Standard 48HJ005
Fig. 43 - Condenser-Fan Adjustment
Fig. 44 - Cooling Charging Chart Standard 48HJ004
Fig. 46 - Cooling Charging Chart Standard 48HJ006
Fig. 47 - Cooling Charging Chart Standard 48HJ007
Fig. 48 - Cooling Charging Chart, 48HJ004 with Optional MoistureMiser Dehumidification Package
Table 29 - LED Error Code Description
Fig. 52 - Burner Section Details Fig. 53 - Burner Tray Details
Fig. 54 - Spark Gap Adjustment
LOW HEAT 48HJE004, 48HJD005-007 - 72,000 BTUH INPUT
MEDIUM AND HIGH HEAT 48HJE005-007, 48HJF004 - 115,000 BTUH INPUT
48HJF005-007 - 150,000 BTUH INPUT
TROUBLESHOOTING
Table 30 - LED Error Code Service Analysis
Table 31 - Heating Service Analysis
Table 32 - Durablade Economizer Service Analysis
Critical
Table 34 - EconoMi$er Troubleshooting
Table 33 - EconoMi$er Flash Code Identification
Table 35 - MoistureMiser Dehumidification Subcooler Service Analysis
Table 36 - Cooling Service Analysis
Compressor operates continuously
Fig. 55 - Typical Wiring Schematic and Component Arrangement
208/230 3-Phase Unit Shown
LEGEND AND NOTES FOR FIG
NOTES FOR FIG
Replaces 48HJ-17SI
Page
START-UP CHECKLIST Remove and Store in Job File
I. PRELIMINARY INFORMATION
II. PRE-START-UP insert checkmark in box as each item is completed
III. START-UP
Related pages
All Diagram page
Cycle chart for Samsung WF8804HPA1/XEH
Wiring Diagram-024, 036 for Bryant 598B
Connection Diagram TVs without Scart terminal for Canon DC 100
Electrical Requirement Chart for Dimension One Spas 2000 Model
Cook Method Chart for KitchenAid KHHC2090S
Features Diagram for Daewoo KOR-810P
EOS 50D Comparison Chart for Canon eos5d
Application Diagrams for Altinex SW1956CT
Spice grinding chart for Hamilton Beach Coffee Grinder
Wiring Diagram for Panasonic MINAS A3 Series
What is the relationship between
CISCO-ENHANCED-MEMORY-POOL-MIB
and OLD-CISCO-MEMORY-MIB?
Top
Page
Image
Contents