Mitsubishi Electronics 882.00207.00 Alarm Log, Typical Alarm Flags & Feeder Setup Screen

Page 92

Alarm Setup

This screen allows the user to configure the feeder type for each feeder; configure whether a feeder will retry during the metering of a batch, and enable or disable the “Out of Material” alarm for any feeder. If a hopper is set to “No Retry” then the blender will continue to meter the rest of the batch even if this hopper runs out of material. No “Out of Material” alarm will be given regardless of how the alarm is configured unless the user has purchased and wired in the low level proximity switches in each hopper. To configure each hopper, perform the following steps:

1.Select a feeder by touching the “Select Feeder” box.

2.The current settings for that hopper will be shown.

3.Make the necessary adjustments and select a new feeder to configure if desired.

4. Press “Done” to exit.

Typical Alarm Flags & Feeder Setup Screen

Select a Feeder to

Configure

Change the Alarm

Silence Delay

Enable or Disable Retries

Enable or Disable Alarms

Go back to Setup Directory

Alarm Log

This screen shows the last 100 stored alarms. The log can be viewed, printed and cleared.

Clear Alarm Log

Print Alarm Log

Typical Alarm Log Screen

Alarm Log

Go back to

Setup

Directory

Scroll Through

Alarm Log

882.00207.00

Chapter 7: Appendix

91 of 102

Image 92
Contents Gravimetric Slide Gate Batch Blender Mitsubishi Controller Parts and Service Department Unpacking and Inspection Event of Shipping DamageIf the Shipment is Not Complete If the Shipment is Not CorrectCredit Returns Warranty ReturnsReturns Table of Contents Maintenance Customer Responsibilities Technical Specifications How to Use This Manual Safety Symbols Used in this ManualSafety Tags and Warning Labels Description Follow all Safety Codes Wear Safety Glasses and Work GlovesOperator Responsibility ResponsibilityGeneral Responsibility Remember Maintenance Responsibility Reporting a Safety DefectAccessories Customer ServiceModels Covered in This Manual General DescriptionEquipment Specifications Controller Features Typical Features and ComponentsMechanical Features System Component Description Supply HoppersSlide Gates Typical Slide Gate Assembly Weigh HopperTypical Weigh Hopper Assembly Mix Chamber Operator Control Panel DisplayController Pushbuttons & Touchscreen Tags Button Function Typical Operator Screens Typical Setup Screens 882.00207.00 Functional Description Optional Components Pneumatic Slide Gate below MixerLow Level Sensors Mezzanine and Floor StandsTake-off Compartments Regrind Auger Metering R.A.M. HopperAdditive Feeder Hopper Safety Features Safety Circuit StandardsSafety Device Lock-Outs Fail Safe OperationElectrical Disconnect Plug Twist Cap Plug Connected to Each Feeder Auger MotorElectric Safety Interlock Switch Electrical Safety Interlock Switch Located on mixer doorMechanical Installation Uncrating the EquipmentMachine Mount Mounting ConfigurationsSite Requirements Mezzanine Mount Typical Mezzanine Mounted Batch BlenderFloor Mount Central Blender Typical Floor Mount Central Blender LayoutElectrical Connections Pneumatic ConnectionsStroke Limiters for Metering Gates Initial Set-upMechanical Set-up Weigh Hopper Final Connections Display Main Recipe Screen Controller Set-upBlender Controller Menu Structure Recipe Page StartBlender Calibration Display Calibration Menu Screen Alarm Setup Feeder Calibration Auger BlendersNetwork Setup Setting Date and TimeAdditional Setup Parameters Initial Startup Quick Start Procedure Start-upGeneral Operation New RecipesOperator Displays Operation ProceduresExisting Recipes Typical Recipe Entry Operator Screen Typical Inventory Display Operator Screen Recipe Entry FormatsQuickset Mode Most common in injection molding Recipe Format MenuExample Calculations of a 5-component blend in Quickset mode Recipe Setup Typical Batch Sizes Blender Batch Size lbs Inventory ShutdownMixer and Dump Setup Weigh Hopper Dump Time Re-Mix TimerWeigh Hopper Dump Delay Time Alarm Flags Weigh Hopper Dump CycleMixer Dump Time Hopper 1-6 Out of MaterialPower Interruption while metering a Batch Max Hopper Weight Exceeded, Check Batch SizeCalibration Error, Clean out Hopper and Check Calibration PLC Battery Low Blender Powered On/OffInventory Cleared Stop ScreenFeeder Clean Out Diagram in -5 of this manual Recipe BookLoad a Saved Recipe from the Book Display Recipe ContentsSave Running Recipe to the Book Erase Recipe or Entire Book Color ChangesShut-down Typical Inventory Shutdown Operator ScreenPreventative Maintenance Schedule Sample Preventative Maintenance SchedulePreventative Maintenance Corrective MaintenanceElectrical Internal Components of the Control PanelInput Signals to Programmable Controller Output Signals from Programmable ControllerTroubleshooting IntroductionProblem Corrective action Problem Corrective action Controller warranty will be voided Problem Corrective action Warranty Warranty SpecificationsWarranty Restrictions Warranty LiabilitiesTechnical Specifications Equipment SpecificationsAnnex B Information Drawings and Diagrams Final AssemblyMixer Sub-Assembly Typical Mixer Assembly Parts List Hopper Sub-Assembly Typical Hopper Assembly Parts ListHopper R.A.M. Regrind Auger Metering Sub-Assembly Optional Typical R.A.M. Hopper Assembly Parts ListHopper Additive Feeder Sub-Assembly Optional Typical Additive Feeder Hopper Assembly Parts ListWeigh Hopper Sub-Assembly Typical Weigh Hopper Assembly Parts ListSlide Gate Sub-Assembly Typical Slidegate Assembly Parts ListKnife Gate Sub-Assembly HD Optional Typical Knife Gate below mixer Assembly Parts ListKnife Gate Sub-Assembly RD Optional Typical Knife Gate floor stand Assembly Parts ListTypical Mitsubishi Controller Main Parts List Control Panel LayoutBlender Spare Parts Listing Spare Parts KitsProgrammable Settings Addendum Service Supervisor InformationPasswords Metering Test Screen Factory Setup MenuAdvanced Weight Options Screen Feed Algorithm Options Screen Feed Calibration Options ScreenFeeder Setup Mechanical Options ScreenCustomer Setup Menu UnitsAlarm Log Typical Alarm Flags & Feeder Setup ScreenFactory Default Setup Parameters Report SetupLoadcell Calex Module Dipswitch Settings Mitsubishi Communications Manual General Blender InfoBlender Alarms Inventory Info Recipe Info this is Where YOU Right the NEW Recipe to Recipe Book Manipulation Alarm Number Explanation Fixed Decimal ExplanationRecording the Targets VS. Actuals for Each Batch Service Department Sales Department Technical AssistanceParts Department Contract Department882.00207.00 Appendix 102
Related manuals
Manual 103 pages 60.12 Kb

882.00207.00 specifications

Mitsubishi Electronics has always been at the forefront of innovation in the field of electronics, and one of its significant products is the Mitsubishi Electronics 882.00207.00. This device is designed for enhanced performance and reliability, providing a range of features that cater to both industrial and consumer needs.

One of the main features of the Mitsubishi 882.00207.00 is its robust design, which ensures durability in demanding environments. The device is built to withstand harsh conditions, making it ideal for industrial applications where reliability is critical. Its rugged construction means that it can operate efficiently in extreme temperatures, humidity, and other challenging conditions.

In terms of technology, the Mitsubishi 882.00207.00 incorporates advanced electronic components that enhance its functionality. This includes state-of-the-art processing capabilities that allow for quick data processing and seamless operation. The device’s integration of cutting-edge technology ensures that it meets the performance demands of modern applications while providing energy efficiency.

Another notable characteristic is its user-friendly interface. The device is designed with ease of use in mind, allowing operators to interact with it effortlessly. This ensures that even those with minimal technical expertise can operate the device effectively. The clear display and intuitive controls make it accessible for a wide range of users, facilitating smoother operations in various settings.

The Mitsubishi 882.00207.00 is also equipped with multiple connectivity options. This enables it to integrate seamlessly with other devices and systems, facilitating enhanced communication and data transfer. Whether it’s connecting to existing networks or interfacing with new technologies, the device’s versatility ensures it can adapt to evolving technological landscapes.

Additionally, the device is backed by Mitsubishi's commitment to quality and customer support. Users can expect reliable service and assistance, ensuring that they can maximize the potential of their investment.

In conclusion, the Mitsubishi Electronics 882.00207.00 stands out in the electronics market for its durable construction, advanced technology, user-friendly design, and versatile connectivity options. This makes it an invaluable tool for both industrial applications and everyday consumer use, embodying the innovative spirit that Mitsubishi Electronics is known for.