Appendix B Cable and Connector Specifications
LX/LH GBIC and MMF Cable Considerations
LX/LH GBIC and MMF Cable Considerations
The following sections describe the things you should consider if you are using a Supervisor Engine 2 with a long wavelength/long haul (LX/LH) GBIC with
Patch Cord
When using the long wavelength/long haul (LX/LH) GBIC with
Note We also recommend using a patch cord between the LX/LH GBIC and MMF cable for very short link distances (10 to 100 meters). Without a patch cord, the link can have an elevated bit error rate (BER).
Note The patch cord is required to comply with IEEE standards. The IEEE found that link distances could not be met with certain types of
Patch Cord Configuration Example
Figure B-8 shows a typical patch cord configuration.
Figure B-8 Patch Cord Configuration
Patch
cord
Rx
Tx
| Building | Patch |
| cable plant | cord |
|
| Tx |
Patch | Patch |
|
panel | panel | port |
|
| Rx |
Link span greater than 984 ft |
| |
| (300 m) |
|
13088
| Cisco 7600 Series Router Supervisor Engine and Route Switch Processor Guide |