Sensor I® Expert User Manual
6. Membrane Keys
Each membrane key has two functions. To access the lower function, simply press the key. The upper function can be accessed by holding in the Reset button and then press the membrane key.
xCp | When this key is pressed (with the Reset button held in), the Mean Value is displayed for |
| approximately 1.5 seconds, then the Cp Value is displayed until the Reset button is |
| released. Repeatedly pressing this key with the Reset button held in, will display Mean |
| and Cp values for Torque or Angle. |
Window | Press this key to display and edit the Torque and Angle high and low limits for a |
| particular tightening mode. Press this key again to go back to the tightening mode. |
s/Cpk | When this key is pressed (with the Reset button held in), the Standard Deviation is |
| displayed for approximately 1.5 seconds, then the Cpk Value is displayed until the Reset |
| button is released. Repeatedly pressing this key with the Reset button held in, will |
| display Standard Deviation and Cpk values for Torque or Angle. |
Display | Pressing this key changes the value that is being displayed on the screen. Each press |
| toggles the display between Peak Torque (Pk), Angle (An), Ld (not used), and Dynamic |
| Torque (Tq). |
Units | Pressing this key will change the torque units displayed for the selected mode. All stored |
| data will also be converted. |
Clear | Pressing this button (while Reset is held in) clears custom tightening modes. This key |
| also clears tightening data stored in memory. |
Joint | This button changes the joint type for Yield Control tightening. |
Store | Press this button (while Reset is held in) to store Curve Trace Data. |
11