Sensor I® Expert User Manual
Statistics
The following statistical information is available for each custom and primary tightening mode:
Mean |
|
| x |
Standard Deviation | σ | ||
Process Capability Index | Cp | ||
Process Capability Index | CpK |
NOTE
Cp and CpK are not available for angle in Dynamic Torque Audit mode as the control limits for low angle (LA) and high angle (HA) are not used.
The statistical calculations are based on all stored final tightening data points for that tightening mode. Lower and upper control limits used for the calculation of the Process Capability Indices, Cp and CpK, use the values of low torque (LT), high torque (HT), low angle (LA) and high angle (HA) entered for each custom and primary tightening mode.
The statistics can be viewed as follows:
1.Select desired custom or primary tightening mode and confirm that the cycle count is a number above zero.
2.While holding in the Reset button, press the x key. The display will show the x symbol on the top of the display and the Pk symbol on the bottom of the display. The main display will show the mean value of the torque which is shown for approximately 1.5 seconds, after which the process capability, Cp, is shown until the Reset button is released.
3.Repeat the above process to display the mean, x, and process capability, Cp, for angle (An).
29