Sensor I® Expert User Manual
1.Set the snug torque to approximately 50% of the expected final torque reading.
2.Set the capture angle (see chart).
3.The operator must then pull the wrench approximately 30° over a period of no more than 2 seconds. Pulling the wrench past the desired audit angle will not have an adverse effect on the audit reading - it will be "captured" at the correct audit angle. The captured torque can be viewed when the parameter shown on the display is "Tq".
|
| Joint Grip Length* (d = bolt diameter) |
| |
Joint Type | ≤ 2d | 2d - 5d | 5d - 10d | >10d |
|
|
|
|
|
Hard/Medium | 2° | 3° | 4° | 6° |
Soft | 2° | 4° | 6° | 8° |
*The grip length is the total length of the bolt located within the assembly pieces. Keep in mind that adding socket extensions will also call for an increase in angle.
This chart is offered as a guideline only. The optimum value for the capture angle will be influenced by the overall joints stiffness, joint configuration, and frictional conditions. Application testing is recommended to determine the most accurate value for the specific joint under audit.