Ingersoll-Rand 4575759 user manual Tightening Curve Data Dump

Page 61

Sensor I® Expert User Manual

1.Complete a tightening.

2.Hold in the Reset button.

3.With the Reset button held in press the Store key.

4.Starting at zero, the screen will then indicate the storage position where the curve will be stored.

5.Release the Reset button.

Tightening Curve Data Dump

The following procedure shows how to initiate a curve data dump.

1.Connect serial cable from the charger/data port to the serial port of the computer.

2.Press the Reset to power up the wrench.

3.Move the Mode Selection switch to Setup.

4.With the Reset button held in, use the Parameter Adjustment Knob to select Custom setup Mode #111. NOTE: The main display shows an inte- ger from 0 to 9.

5.Release the Reset button.

6.Move the Mode Selection switch to Torque Control.

7.Hold in the Reset button and rotate Parameter Adjustment Knob to select the curve buffer number to be transmitted.

8.Press the Display key. The main display will show the number of sample points in the selected curve buffer to be transmitted. The "Tx" will flash while the serial data is being sent. When all the data, parameter and

39

Image 61
Contents Sensor I Expert Electronic Wrenches Page Form 7266 Version 005, 08/04 Sensor I ExpertPage Page Page Wrench Reset To Dynamically Audit Residual Torque Dynamic Audit≤ 2d To Tighten to an Angle To Tighten to a TorqueTo Tighten to Yield Page Page Table of Contents Page Table of Contents Battery Charging Introduction ChapterPage Introduction Page Tool Description Page Tool Description Technical Data 125 250 400Page Expert 125, 250 and 400 Models Functions of ComponentsExpert Control System Status Lights Mode Selector Switch Digital Display Page Membrane Keys Audible Alarm Item no Longer in USE Page Operation Instructions Page General Information Wrench Operation InstructionsSetting Torque Units Torque Control Tightening Procedure Page Dynamic Audit Page Yield Control Page Angle Control Page Cycle Counter Resetting the Cycle CounterQuality Control Limits and Statistics Setup and Viewing Quality Control LimitsDeleting Quality Control Limits Use of Quality Control Limits Mean Standard Deviation Process Capability Index StatisticsCustom Tightening Modes Setup and Storage of Custom Tightening ModesIdentifying Custom Tightening Modes Retrieving Custom Tightening ModesClearing Custom Tightening Modes Data Storage and Retrieval Setup of Wrench for Data UploadLast two numerals are not shown on the wrench display Data Out During TighteningData Out at End of Tightening Parameter Dump End of Tightening Data Dump Tightening Curve Storage Tightening Curve Data Dump Torque Multiplier Function Setup of a Torque MultiplierPage Use of a Torque Multiplier Left Hand FastenersReset Adjustment EVS-models only Page Reset Adjustment Value Models 125, 250 Page Battery Charging Page Battery Charging Page Diagnostics Troubleshooting Page Torque Channel A/D Display Custom Mode #200 Diagnostics and TroubleshootingAngle Reference Arm Test Mode EA Models, Custom Mode IntroductionEZ Angle Test Mode Custom Mode #207 Battery Level Test Mode Custom Mode #204Membrane Keypad Test Mode Custom Mode #208 Buzzer and LED Test Mode Custom Mode #209Time-out Adjustment Custom Mode #212 Software Version Number Test Custom Mode #211Page Calibration Page General Information CalibrationTorque Calibration Page EZ Angle Calibration EVS models Angle Reference Arm Calibration EA modelsPage Page Sample Data Reports Appendix aPage Sample Reports Parameter Dump Appendix aEnd of Tightening Data Dump Torque Torque Units Nm Tightening Curve Data DumpData Out During Tightening Data Out at End of TighteningPage Appendix B List Setup ModesPage Custom Modes Appendix BCustom Mode Appendix C Spare Parts ListPage Appendix C Spare Parts Listing ModelE40-STRP Spare Parts Listing Model 40E40-PR-LABEL Spare Parts Listing Model Spare Parts Listing Model 125 Spare Parts Listing Model Spare Parts Listing Model 250 Spare Parts Listing Model Spare Parts Listing Model 400 Page Appendix D Service CentersPage Appendix D Service CentersSensor I Expert Electronic Wrenches Save These INSTRUCTIONS. do not Destory Ingersoll-Rand Company