6.Press the Display key until "Pk" is displayed on the lower
7.Press in the Reset button. The snug torque will be displayed.
8.With the Reset button held in, use the Parameter Adjustment Knob to adjust the snug torque to the desired value.
9.Release the Reset button. If the FAULT light is lit, then press and hold the Reset button again while holding the wrench steady. Con- tinue to hold in the Reset until the RUN light appears and the FAULT light goes off. Release Reset.
10.Press the Display key until "An" appears in the lower
11.Commence tightening with moderate speed steady pulls. Stop as soon as the OK light comes on and the alarm sounds.
12.When tightening is complete, press the Display key until "Pk" appears in the lower
24