Ingersoll-Rand 4575759 user manual Left Hand Fasteners, Use of a Torque Multiplier

Page 64

Sensor I® Expert User Manual

8.Release the Reset button and rotate the Mode switch to the tightening mode position for which the multiplier was enabled. The multiplier is now enabled for that primary tightening mode.

NOTE

It is only possible to have one programmable multiplier value in operation at any time.

NOTE

Entering the multiplier set mode for a particular tightening mode resets the cycle count and flushes the data buffer for that mode.

Use of a Torque Multiplier

The torque multiplier can be used when the capacity of the Expert wrench is below that required for the tightening application.

Once setup as described in Setup of a Torque Multiplier, the wrench is then used in any of the primary modes as previously described. The joint selection setting should be set at “soft” joints for Yield Control Tightening. This is done by using the Joint key.

NOTE

Users should be aware of any torque reaction requirements or capacity restrictions on the torque multiplier being used.

LEFT HAND FASTENERS

Custom Setup Mode #103 allow the user to select tightening direction (CW or CCW).

1. The wrench display shows "---".

42

Image 64
Contents Sensor I Expert Electronic Wrenches Page Sensor I Expert Form 7266 Version 005, 08/04Page Page Page Wrench Reset Dynamic Audit To Dynamically Audit Residual Torque≤ 2d To Tighten to an Angle To Tighten to a TorqueTo Tighten to Yield Page Page Table of Contents Page Table of Contents Battery Charging Chapter IntroductionPage Introduction Page Tool Description Page Technical Data 125 250 400 Tool DescriptionPage Functions of Components Expert 125, 250 and 400 ModelsExpert Control System Status Lights Mode Selector Switch Digital Display Page Membrane Keys Audible Alarm Item no Longer in USE Page Operation Instructions Page Wrench Operation Instructions General InformationSetting Torque Units Torque Control Tightening Procedure Page Dynamic Audit Page Yield Control Page Angle Control Page Resetting the Cycle Counter Cycle CounterSetup and Viewing Quality Control Limits Quality Control Limits and StatisticsDeleting Quality Control Limits Use of Quality Control Limits Statistics Mean Standard Deviation Process Capability IndexSetup and Storage of Custom Tightening Modes Custom Tightening ModesRetrieving Custom Tightening Modes Identifying Custom Tightening ModesClearing Custom Tightening Modes Setup of Wrench for Data Upload Data Storage and RetrievalData Out During Tightening Last two numerals are not shown on the wrench displayData Out at End of Tightening Parameter Dump End of Tightening Data Dump Tightening Curve Storage Tightening Curve Data Dump Setup of a Torque Multiplier Torque Multiplier FunctionPage Left Hand Fasteners Use of a Torque MultiplierReset Adjustment EVS-models only Page Reset Adjustment Value Models 125, 250 Page Battery Charging Page Battery Charging Page Diagnostics Troubleshooting Page Diagnostics and Troubleshooting Torque Channel A/D Display Custom Mode #200Angle Reference Arm Test Mode EA Models, Custom Mode IntroductionBattery Level Test Mode Custom Mode #204 EZ Angle Test Mode Custom Mode #207Membrane Keypad Test Mode Custom Mode #208 Buzzer and LED Test Mode Custom Mode #209Software Version Number Test Custom Mode #211 Time-out Adjustment Custom Mode #212Page Calibration Page Calibration General InformationTorque Calibration Page Angle Reference Arm Calibration EA models EZ Angle Calibration EVS modelsPage Page Appendix a Sample Data ReportsPage Appendix a Sample Reports Parameter DumpEnd of Tightening Data Dump Torque Tightening Curve Data Dump Torque Units NmData Out at End of Tightening Data Out During TighteningPage List Setup Modes Appendix BPage Appendix B Custom ModesCustom Mode Spare Parts List Appendix CPage Spare Parts Listing Model Appendix CSpare Parts Listing Model 40 E40-STRPE40-PR-LABEL Spare Parts Listing Model Spare Parts Listing Model 125 Spare Parts Listing Model Spare Parts Listing Model 250 Spare Parts Listing Model Spare Parts Listing Model 400 Page Service Centers Appendix DPage Service Centers Appendix DSensor I Expert Electronic Wrenches Save These INSTRUCTIONS. do not Destory Ingersoll-Rand Company