Sierra S5832SG RPS Callback Enable Comments, Keypad RPS Enable Comments, Dialer Retry Sequence

Page 27

Block 4 - Digital Communicator Programming (cont.)

RPS Callback Enable

Comments

 

 

 

If enabled, requires the panel to call COMMANDER II in

Cmd Loc

105

 

Default

1

 

order to establish RPS. If disabled, the panel will stay on-line

Range

1 - 2

 

when called by COMMANDER II the second time (following

 

 

 

handshaking).

 

 

 

Options:

1No

2 Yes

Keypad RPS Enable

Comments

Cmd Loc

106

 

If enabled, allows remote programming to be initiated from

Default

2

 

the keypad (either Block 0 or user programming).

Range

1 - 2

 

 

 

 

 

 

Options:

1No

2 Yes

RPS and CFSK-IV Modem Type

Comments

Options:

Cmd Loc

Default

Range

107

2

1 - 2

Establishes the modem protocol for RPS and CFSK-IV

1

Bell 103

communications.

2

CCITT

Alarm Dialing Delay (Seconds)

Comments

Cmd Loc

Default

Range

108

0

0 - 255

The delay (in seconds) after an alarm occurs before the report is sent.

24-Hour Zone Dial Delay

Comments

Options:

Cmd Loc

Default

Range

109

1

1 - 2

If enabled, uses the time programmed above (Block 4, CL

1

No

108) for reporting alarms on 24-hour zones. If disabled, 24-

2

Yes

hour zones report immediately.

 

 

Cancel Report Delay (Seconds)

Comments

Cmd Loc

Default

Range

110

0

0 - 255

The amount of time (in seconds), following an alarm, during which a cancel report may be sent. The cancel report is not sent if a valid user code is entered before the alarm dialing delay has expired.

Dialer Retry Sequence

Cmd Loc

111

Default

4

Range

1 - 4

 

 

Options:

1Repeat Call Attempt

Series Every 30 min.

2Repeat Call Attempt Series Every four hrs.

3Repeat Call Attempt Series at 30 min.

then double interval up to 128 hrs.

4No additional Call Attempts After Failed Series Until New Report is Queued.

Phone Line Call Routing

Cmd Loc 112

Default 1

Range 1 - 4

Options:

1Line #1 Only

2Line #1 with Line #2 Backup (Phone Line Cut or Comm Fail)

3Line #1 with Line #2 as Backup, Alternating (2 Attempts Each)

4Line #1 with Line #2 as Backup, Alternating (4 Attempts Each)

Test Report Interval (Days)

Comments

Cmd Loc

Default

Range

113

7

0 - 30

This option determines the test interval. Test reports are sent in daily intervals, ranging from 1 to 30 days. The time of day for the report is programmed into Block 4, CL 114. To disable reporting, set to 0.

Test Report Time of Day (Hours)

Comments

Cmd Loc

Default

Range

114

1

0 - 23

When programming the test report time of day, use the 24-hour format. (Add 12 hours for afternoon and evening times.)

Ringback Outputs Enable

Comments

Options:

Cmd Loc

Default

Range

115

0

0 - 15

The selected outputs will sound for three sec-

0

Disable

onds following a successful closing report.

1

Keypad Buzzer

 

2

Strobe

 

4

Internal Siren

 

8

External Bell

23

Image 27
Contents Installation Instructions Page Table of Contents Singapore Sierra Accessory LoadingAH Requirements for Backup Country Specific Compliance InformationEarth Ground Panel Setup and InstallationIntroduction Mounting the PanelWiring Knock-outs Top AC Power Backup BatteryAH Requirements for Backup Sierra Accessory LoadingOutput Terminals Keypad WiringKeypad Wiring Sierra Accessory Wiring DistancesS5050 Relay/Event Memory Module AccessoriesZone Terminals On-Board Relay Terminals TB2S5058 Zone Expansion Module Digital Communicator Connections SN915-BUS SpreadNet ReceiverSN990/991 SpreadNet Keypad/Remote SN961 SpreadNet KeyfobProgramming the Panel Remote Programming RPSTerminal Connections Zone LEDs Cmd Loc Data Value Press Home to activate the RPS featureProgramming With an LED Keypad ValueProgramming With an Icon Keypad Quick Programming ModeMenu Programming Mode Programming With an Alpha KeypadInstaller Mode Options, Block Installer Walk-TestEvent Memory Battery Test Bypass 0 Home CancelEntry Delay Test Exit Delay TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Audible Cadence Zones 1 Chime Enable ZonesZone Bypass Enable Zones Zone Response Time Zones 1Block 3 Armed System Programming Low Battery Arming Comments Options Quick Bypass Enable CommentsHome Arm Exit Delay Enable 4X Exit Delay Extension Enable Comments OptionsSwinger Alarm Lockout Limit Comments Auto-Arming Enable AreaAuto-Disarming Enable Area Comments Auto-Disarming Enable Day of WeekDuress Active Only When Area Armed Sounder Turn-On Delay Following Alarm Seconds CommentsStrobe/Siren Disable with Low Battery Comments Options Soak Mode Learning Period Duration DaysHome Arming Enable Comments Options Keypad Tamper Switch Enable By Address Keypad #External Bell Reverse Enable Comments Options Sounder Bell Test Enable By Area CommentsBlock 4 Digital Communicator Programming Account #6 Account #3Account #4 Account #5Hour Zone Dial Delay Comments Options RPS Callback Enable CommentsKeypad RPS Enable Comments Alarm Dialing Delay Seconds CommentsKeypad and Accessory Tamper Report Routing Comments Power Supply Report RoutingInstaller Programming Report Routing Comments SpreadNet Transmitter Low Battery Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Tamper Zones 1 Report Code, Restoral Zones 1Report Code, Zone Bypass Zones 1 Comments Report Code, Trouble Zones 1 CommentsReport Code, Low Battery Report Code, Cancel Users 1 User #Report Code, AC Power Loss Report Code, AC Power RestoralReport Code, Ground Fault Restoral Report Code, Installer Programming StartReport Code, Installer Programming Complete Report Code, Ground FaultReport Code, Accessory Tamper Restoral Report Code, SpreadNet Keypad/Keyfob Low BatteryReport Code, SpreadNet Keypad/Keyfob Low Battery Restoral Report Code, Accessory TamperBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Timer Units Remm #1, Relay #1 Exit Delay TerminatorTimer Units On Board Relay Timer Count On Board RelayTimer Count Remm #2, Relay #2 Timer Units Remm #2, Relay #1Timer Count Remm #2, Relay #1 Timer Units Remm #8, Relay #2Timed Relay Closing Timer #2 Day of Week Timed Relay Closing Timer #1 Day of WeekTimed Relay Closing Timer #1 Hours Timed Relay Closing Timer #1 MinutesBlock 9 Partition Area Programming Block 8 SpreadNet ProgrammingArea Assignments SpreadNet Keypads 1 Area Access by User Number User # 1First to Open/Last to Close Enable Comments Options Keypad Assignments to Areas Keypads 1Area Access SN Keyfob/Remote # 1 Block 10 User Code ProgrammingUser Codes User # 1 User Codes User Codes Comments