Sierra S5832SG Report Code, Primary Phone Line Restoral, Report Code, Secondary Phone Line Cut

Page 32

Report Code, Primary Phone Line Restoral

Cmd Loc

129

130

 

Default

0

0

 

Range

0 - 15

(All Locations)

Block 5 - Reporting Digits Programming (cont.)

Comments

These two-digit codes are sent when the system detects a primary or secondary phone line cut, or their respective restorals. When using single- digit reporting formats, only the second digit is sent.

Report Code, Secondary Phone Line Cut

Cmd Loc

131

132

 

Default

0

0

 

Range

0 - 15

(All

Locations)

Report Code, Secondary Phone Line Restoral

Cmd Loc

133

134

 

Default

0

0

 

Range

0 - 15

(All Locations)

Report Code, Installer Programming Start

Cmd Loc

135

136

 

Default

0

0

 

Range

0 - 15

(All Locations)

Comments

This two-digit report code will be sent to indicate the start of installer pro- gramming. Single-digit reporting formats will only send the second digit to the central station.

Report Code, Installer Programming Complete

Cmd Loc

137

138

 

Default

0

1

 

Range

0 - 15

(All Locations)

Report Code, Bell Supervision Trouble

Comments

Cmd Loc

139

140

 

These two-digit report codes will be sent to indicate an external bell super-

Default

0

0

 

vision trouble condition or a restoral report. When using single-digit report-

Range

0 - 15

(All Locations)

ing formats, only the second digit will be sent.

Report Code, Bell Supervision Trouble Restoral

 

Cmd Loc

141

142

 

 

Default

0

0

 

 

Range

0 - 15

(All Locations)

 

Report Code, SpreadNet Supervisory Trouble

Zones:

1 - 8

9 - 16

17 - 24

25 - 32

Cmd Loc

143

144

145

146

Default

1

1

1

1

Range

0 - 15

0 - 15

0 - 15

0 - 15

Comments

The SpreadNet supervisory trouble and supervisory trouble restoral re- port codes are single-digit codes. For two-digit reporting formats, the relative zone number (1 - 8) is sent as the second digit. Program the specific Cmd Loc with 0 to disable reporting. Disabling a Cmd Loc dis- ables reporting for all zones associated with that location.

Report Code, SN Supervisory Trouble Restoral

Zones:

1 - 8

9 - 16

17 - 24

25 - 32

Cmd Loc

147

148

149

150

Default

1

1

1

1

Range

0 - 15

0 - 15

0 - 15

0 - 15

Report Code, SN Transmitter Low Battery Zones: 1 - 8 9 - 16 17 - 24 25 - 32

Cmd Loc

151

152

153

154

Default

1

1

1

1

Range

0 - 15

0 - 15

0 - 15

0 - 15

Report Code, SN Tx Low Battery Restoral Zones: 1 - 8 9 - 16 17 - 24 25 - 32

Cmd Loc

155

156

157

158

Default

1

1

1

1

Range

0 - 15

0 - 15

0 - 15

0 - 15

Comments

The SpreadNet low battery and low battery restoral report codes are a single-digit code. For two-digit reporting formats, the relative zone number (1 - 8) is sent as the second digit. Program the specific Cmd Loc with 0 to disable reporting. Disabling a Cmd Loc disables reporting for all zones associated with that location.

Report Code, Ground Fault

Cmd Loc

159

160

 

Default

0

0

 

Range

0 - 15

(All

CL)

Comments

These two-digit report codes will be sent to indicate a ground fault condi- tion or restoral report. When using single-digit reporting formats, only the second digit will be sent.

Report Code, Ground Fault Restoral

Cmd Loc

Default

Range

161

162

0

0

0 - 15

(All CL)

28

Image 32
Contents Installation Instructions Page Table of Contents Sierra Accessory Loading AH Requirements for BackupCountry Specific Compliance Information SingaporePanel Setup and Installation IntroductionMounting the Panel Earth GroundWiring Knock-outs Top Backup Battery AH Requirements for BackupSierra Accessory Loading AC PowerKeypad Wiring Keypad WiringSierra Accessory Wiring Distances Output TerminalsAccessories Zone TerminalsOn-Board Relay Terminals TB2 S5050 Relay/Event Memory ModuleS5058 Zone Expansion Module SN915-BUS SpreadNet Receiver SN990/991 SpreadNet Keypad/RemoteSN961 SpreadNet Keyfob Digital Communicator ConnectionsTerminal Connections Programming the PanelRemote Programming RPS Press Home to activate the RPS feature Programming With an LED KeypadValue Zone LEDs Cmd Loc Data ValueQuick Programming Mode Menu Programming ModeProgramming With an Alpha Keypad Programming With an Icon KeypadEvent Memory Installer Mode Options, BlockInstaller Walk-Test Bypass 0 Home Cancel Entry Delay TestExit Delay Test Battery TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Chime Enable Zones Zone Bypass Enable ZonesZone Response Time Zones 1 Audible Cadence Zones 1Block 3 Armed System Programming Quick Bypass Enable Comments Home Arm Exit Delay Enable4X Exit Delay Extension Enable Comments Options Low Battery Arming Comments OptionsAuto-Arming Enable Area Auto-Disarming Enable Area CommentsAuto-Disarming Enable Day of Week Swinger Alarm Lockout Limit CommentsSounder Turn-On Delay Following Alarm Seconds Comments Strobe/Siren Disable with Low Battery Comments OptionsSoak Mode Learning Period Duration Days Duress Active Only When Area ArmedKeypad Tamper Switch Enable By Address Keypad # External Bell Reverse Enable Comments OptionsSounder Bell Test Enable By Area Comments Home Arming Enable Comments OptionsBlock 4 Digital Communicator Programming Account #3 Account #4Account #5 Account #6RPS Callback Enable Comments Keypad RPS Enable CommentsAlarm Dialing Delay Seconds Comments Hour Zone Dial Delay Comments OptionsPower Supply Report Routing Installer Programming Report Routing CommentsSpreadNet Transmitter Low Battery Report Routing Comments Keypad and Accessory Tamper Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Restoral Zones 1 Report Code, Zone Bypass Zones 1 CommentsReport Code, Trouble Zones 1 Comments Report Code, Tamper Zones 1Report Code, Cancel Users 1 User # Report Code, AC Power LossReport Code, AC Power Restoral Report Code, Low BatteryReport Code, Installer Programming Start Report Code, Installer Programming CompleteReport Code, Ground Fault Report Code, Ground Fault RestoralReport Code, SpreadNet Keypad/Keyfob Low Battery Report Code, SpreadNet Keypad/Keyfob Low Battery RestoralReport Code, Accessory Tamper Report Code, Accessory Tamper RestoralBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Exit Delay Terminator Timer Units On Board RelayTimer Count On Board Relay Timer Units Remm #1, Relay #1Timer Units Remm #2, Relay #1 Timer Count Remm #2, Relay #1Timer Units Remm #8, Relay #2 Timer Count Remm #2, Relay #2Timed Relay Closing Timer #1 Day of Week Timed Relay Closing Timer #1 HoursTimed Relay Closing Timer #1 Minutes Timed Relay Closing Timer #2 Day of WeekBlock 8 SpreadNet Programming Block 9 Partition Area ProgrammingArea Access by User Number User # 1 First to Open/Last to Close Enable Comments OptionsKeypad Assignments to Areas Keypads 1 Area Assignments SpreadNet Keypads 1User Codes User # 1 Area Access SN Keyfob/Remote # 1Block 10 User Code Programming User Codes User Codes Comments