Sierra S5832SG Zone Response Time Zones 1, Audible Cadence Zones 1, Zone Circuit Type Zones 1

Page 19

Block 2 - Zone Configuration Programming (cont.)

Zone Response Time (Zones 1 - 8)

Cmd Loc

068

069

070

071

072

073

074

075

Zone #

1

2

3

4

5

6

7

8

Cmd Loc

076

(Zone Expander Module #1)

Zone #

9 thru 16

 

 

 

 

 

 

Cmd Loc

077

(Zone Expander Module #2)

Zone #

17 thru 24

 

 

 

 

 

 

Cmd Loc

078

(Zone Expander Module #3)

Zone #

25 thru 32

 

 

 

 

 

 

Default

2 (All CL)

 

 

 

 

 

 

Range

1 - 2 (All CL)

 

 

 

 

 

Comments

These Options select the zone response time (in mil- liseconds) of zones 1 - 8 and zones available from the S5058 Zone Expansion Module.

All zones on the S5058 ZEM use the same re- sponse time.

Options:

1250 mS

2 500 mS

Audible Cadence (Zones 1 - 32)

Cmd Loc

079

080

081

082

083

084

085

086

Zone #

1

2

3

4

5

6

7

8

Cmd Loc

087

088

089

090

091

092

093

094

Zone #

9

10

11

12

13

14

15

16

Cmd Loc

095

096

097

098

099

100

101

102

Zone #

17

18

19

20

21

22

23

24

Cmd Loc

103

104

105

106

107

108

109

110

Zone #

25

26

27

28

29

30

31

32

Default

3 (All CL)

 

 

 

 

 

 

Range

1 - 7 (All CL)

 

 

 

 

 

Comments

These options program the opera- tion of the internal and external sounders. Both internal and exter- nal sounders will operate together. Programming options 5 and 6 also limit the duration of the sounder outputs.

Exceptions are: Keyswitch/Spread- Net Arming Annunciation (Block 3, CL 051) and Ringback (Block 4, CL 115).

Options:

1Keypad Buzzer

2Pulsing Sounder (1.5s on/off)

3 Steady Sounder

4 Temporal Code 3 (0.5s on/

0.5s off 2x, 0.5s on/ 1.5s off)

5 On 1 Min./Off 30s (repeated twice)

6 On 1 Min./Off 30s

(repeated 5x)

7 Silent

Zone Circuit Type (Zones 1 - 32)

Cmd Loc

111

112

113

114

115

116

117

118

Zone #

1

2

3

4

5

6

7

8

Cmd Loc

119

120

121

122

123

124

125

126

Zone #

9

10

11

12

13

14

15

16

Cmd Loc

127

128

129

130

131

132

133

134

Zone #

17

18

19

20

21

22

23

24

Cmd Loc

135

136

137

138

139

140

141

142

Comments

Tamper zones use 2 EOL resistors and may detect 4 discreet conditions (normal, fault/ alarm, trouble, and tamper).

If any zone is designated as a SpreadNet zone, it will automatically be ignored as a hardwired zone.

Options:

1Normally Closed

2 Normally Open

3 EOL

4 Supervised EOL

5 Tamper (2 EOL)

6 SpreadNet RF

Zone #

25 26 27 28 29 30 31 32

Default

3

(All CL)

Range

1 -

6 (All CL)

For devices requiring 10K EOL resistor, use zone 7 and remove J5. Refer to the S5090 Sierra Reference Manual for additional information.

Chime Enable

Zones:

1 - 8

9 - 16

17 - 24

25 - 32

Cmd Loc

143

144

145

146

Default

0

0

0

0

Range

0 - 255

0 - 255

0 - 255

0 - 255

 

 

 

 

 

Comments

If programmed for chime, these zones will sound at the keypad when the control panel is disarmed and the zone is faulted. It is used for delay, interior, and instant zones only. The program value is a total of all zones in the group which will have Chime enabled.

Options:

0

Disabled

 

 

1

Zone 1 9 17 25

2

Zone

2

10 18

26

4

Zone

3

11 19

27

8

Zone

4

12 20

28

16

Zone

5

13 21

29

32

Zone

6

14 22

30

64

Zone

7

15 23

31

128

Zone

8

16 24

32

Zone Bypass Enable

Zones:

1 - 8

9 - 16

17 - 24

25 - 32

Cmd Loc

147

148

149

150

Default

255

255

255

255

Range

0 - 255

0 - 255

0 - 255

0 - 255

 

 

 

 

 

Comments

These four command locations determine which zones a user may manually bypass (if authorized in Block 1, CL 021 - 080).

Zone bypass enable is divided into groups of 8 zones each. The program value is a total of all zones in the group which may be by- passed.

Options:

0

Disabled

 

 

1

Zone 1 9 17 25

2

Zone

2

10 18

26

4

Zone

3

11 19

27

8

Zone

4

12 20

28

16

Zone

5

13 21

29

32

Zone

6

14 22

30

64

Zone

7

15 23

31

128

Zone

8

16 24

32

15

Image 19
Contents Installation Instructions Page Table of Contents Singapore Sierra Accessory LoadingAH Requirements for Backup Country Specific Compliance InformationEarth Ground Panel Setup and InstallationIntroduction Mounting the PanelWiring Knock-outs Top AC Power Backup BatteryAH Requirements for Backup Sierra Accessory LoadingOutput Terminals Keypad WiringKeypad Wiring Sierra Accessory Wiring DistancesS5050 Relay/Event Memory Module AccessoriesZone Terminals On-Board Relay Terminals TB2S5058 Zone Expansion Module Digital Communicator Connections SN915-BUS SpreadNet ReceiverSN990/991 SpreadNet Keypad/Remote SN961 SpreadNet KeyfobRemote Programming RPS Programming the PanelTerminal Connections Zone LEDs Cmd Loc Data Value Press Home to activate the RPS featureProgramming With an LED Keypad ValueProgramming With an Icon Keypad Quick Programming ModeMenu Programming Mode Programming With an Alpha KeypadInstaller Walk-Test Installer Mode Options, BlockEvent Memory Battery Test Bypass 0 Home CancelEntry Delay Test Exit Delay TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Audible Cadence Zones 1 Chime Enable ZonesZone Bypass Enable Zones Zone Response Time Zones 1Block 3 Armed System Programming Low Battery Arming Comments Options Quick Bypass Enable CommentsHome Arm Exit Delay Enable 4X Exit Delay Extension Enable Comments OptionsSwinger Alarm Lockout Limit Comments Auto-Arming Enable AreaAuto-Disarming Enable Area Comments Auto-Disarming Enable Day of WeekDuress Active Only When Area Armed Sounder Turn-On Delay Following Alarm Seconds CommentsStrobe/Siren Disable with Low Battery Comments Options Soak Mode Learning Period Duration DaysHome Arming Enable Comments Options Keypad Tamper Switch Enable By Address Keypad #External Bell Reverse Enable Comments Options Sounder Bell Test Enable By Area CommentsBlock 4 Digital Communicator Programming Account #6 Account #3Account #4 Account #5Hour Zone Dial Delay Comments Options RPS Callback Enable CommentsKeypad RPS Enable Comments Alarm Dialing Delay Seconds CommentsKeypad and Accessory Tamper Report Routing Comments Power Supply Report RoutingInstaller Programming Report Routing Comments SpreadNet Transmitter Low Battery Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Tamper Zones 1 Report Code, Restoral Zones 1Report Code, Zone Bypass Zones 1 Comments Report Code, Trouble Zones 1 CommentsReport Code, Low Battery Report Code, Cancel Users 1 User #Report Code, AC Power Loss Report Code, AC Power RestoralReport Code, Ground Fault Restoral Report Code, Installer Programming StartReport Code, Installer Programming Complete Report Code, Ground FaultReport Code, Accessory Tamper Restoral Report Code, SpreadNet Keypad/Keyfob Low BatteryReport Code, SpreadNet Keypad/Keyfob Low Battery Restoral Report Code, Accessory TamperBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Timer Units Remm #1, Relay #1 Exit Delay TerminatorTimer Units On Board Relay Timer Count On Board RelayTimer Count Remm #2, Relay #2 Timer Units Remm #2, Relay #1Timer Count Remm #2, Relay #1 Timer Units Remm #8, Relay #2Timed Relay Closing Timer #2 Day of Week Timed Relay Closing Timer #1 Day of WeekTimed Relay Closing Timer #1 Hours Timed Relay Closing Timer #1 MinutesBlock 9 Partition Area Programming Block 8 SpreadNet ProgrammingArea Assignments SpreadNet Keypads 1 Area Access by User Number User # 1First to Open/Last to Close Enable Comments Options Keypad Assignments to Areas Keypads 1Block 10 User Code Programming Area Access SN Keyfob/Remote # 1User Codes User # 1 User Codes User Codes Comments