Block 2 - Zone Configuration Programming (cont.)
Zone Response Time (Zones 1 - 8)
Cmd Loc | 068 | 069 | 070 | 071 | 072 | 073 | 074 | 075 |
Zone # | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Cmd Loc | 076 | (Zone Expander Module #1) | ||||||
Zone # | 9 thru 16 |
|
|
|
|
|
| |
Cmd Loc | 077 | (Zone Expander Module #2) | ||||||
Zone # | 17 thru 24 |
|
|
|
|
|
| |
Cmd Loc | 078 | (Zone Expander Module #3) | ||||||
Zone # | 25 thru 32 |
|
|
|
|
|
| |
Default | 2 (All CL) |
|
|
|
|
|
| |
Range | 1 - 2 (All CL) |
|
|
|
|
|
Comments
These Options select the zone response time (in mil- liseconds) of zones 1 - 8 and zones available from the S5058 Zone Expansion Module.
All zones on the S5058 ZEM use the same re- sponse time.
Options:
1250 mS
2 500 mS
Audible Cadence (Zones 1 - 32)
Cmd Loc | 079 | 080 | 081 | 082 | 083 | 084 | 085 | 086 |
Zone # | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Cmd Loc | 087 | 088 | 089 | 090 | 091 | 092 | 093 | 094 |
Zone # | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Cmd Loc | 095 | 096 | 097 | 098 | 099 | 100 | 101 | 102 |
Zone # | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Cmd Loc | 103 | 104 | 105 | 106 | 107 | 108 | 109 | 110 |
Zone # | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 |
Default | 3 (All CL) |
|
|
|
|
|
| |
Range | 1 - 7 (All CL) |
|
|
|
|
|
Comments
These options program the opera- tion of the internal and external sounders. Both internal and exter- nal sounders will operate together. Programming options 5 and 6 also limit the duration of the sounder outputs.
Exceptions are: Keyswitch/Spread- Net Arming Annunciation (Block 3, CL 051) and Ringback (Block 4, CL 115).
Options:
1Keypad Buzzer
2Pulsing Sounder (1.5s on/off)
3 Steady Sounder
4 Temporal Code 3 (0.5s on/
0.5s off 2x, 0.5s on/ 1.5s off)
5 On 1 Min./Off 30s (repeated twice)
6 On 1 Min./Off 30s
(repeated 5x)
7 Silent
Zone Circuit Type (Zones 1 - 32)
Cmd Loc | 111 | 112 | 113 | 114 | 115 | 116 | 117 | 118 |
Zone # | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Cmd Loc | 119 | 120 | 121 | 122 | 123 | 124 | 125 | 126 |
Zone # | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Cmd Loc | 127 | 128 | 129 | 130 | 131 | 132 | 133 | 134 |
Zone # | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Cmd Loc | 135 | 136 | 137 | 138 | 139 | 140 | 141 | 142 |
Comments
Tamper zones use 2 EOL resistors and may detect 4 discreet conditions (normal, fault/ alarm, trouble, and tamper).
If any zone is designated as a SpreadNet zone, it will automatically be ignored as a hardwired zone.
Options:
1Normally Closed
2 Normally Open
3 EOL
4 Supervised EOL
5 Tamper (2 EOL)
6 SpreadNet RF
Zone # | 25 26 27 28 29 30 31 32 | |
Default | 3 | (All CL) |
Range | 1 - | 6 (All CL) |
For devices requiring 10K EOL resistor, use zone 7 and remove J5. Refer to the S5090 Sierra Reference Manual for additional information.
Chime Enable
Zones: | 1 - 8 | 9 - 16 | 17 - 24 | 25 - 32 |
Cmd Loc | 143 | 144 | 145 | 146 |
Default | 0 | 0 | 0 | 0 |
Range | 0 - 255 | 0 - 255 | 0 - 255 | 0 - 255 |
|
|
|
|
|
Comments
If programmed for chime, these zones will sound at the keypad when the control panel is disarmed and the zone is faulted. It is used for delay, interior, and instant zones only. The program value is a total of all zones in the group which will have Chime enabled.
Options:
0 | Disabled |
|
| |
1 | Zone 1 9 17 25 | |||
2 | Zone | 2 | 10 18 | 26 |
4 | Zone | 3 | 11 19 | 27 |
8 | Zone | 4 | 12 20 | 28 |
16 | Zone | 5 | 13 21 | 29 |
32 | Zone | 6 | 14 22 | 30 |
64 | Zone | 7 | 15 23 | 31 |
128 | Zone | 8 | 16 24 | 32 |
Zone Bypass Enable
Zones: | 1 - 8 | 9 - 16 | 17 - 24 | 25 - 32 |
Cmd Loc | 147 | 148 | 149 | 150 |
Default | 255 | 255 | 255 | 255 |
Range | 0 - 255 | 0 - 255 | 0 - 255 | 0 - 255 |
|
|
|
|
|
Comments
These four command locations determine which zones a user may manually bypass (if authorized in Block 1, CL 021 - 080).
Zone bypass enable is divided into groups of 8 zones each. The program value is a total of all zones in the group which may be by- passed.
Options:
0 | Disabled |
|
| |
1 | Zone 1 9 17 25 | |||
2 | Zone | 2 | 10 18 | 26 |
4 | Zone | 3 | 11 19 | 27 |
8 | Zone | 4 | 12 20 | 28 |
16 | Zone | 5 | 13 21 | 29 |
32 | Zone | 6 | 14 22 | 30 |
64 | Zone | 7 | 15 23 | 31 |
128 | Zone | 8 | 16 24 | 32 |