Sierra S5832SG Programming With an Alpha Keypad, Programming With an Icon Keypad

Page 14

Programming With an Alpha Keypad

Upon entering the installer programming mode, the display will ask you which language you wish to use for program- ming the panel. Each panel supports three languages, one of which is English. The other languages are determined by the model number of the panel. The Alphanumeric keypad provides two panel programming options: Quick or Menu programming. Both options use a combination of text and numbers in the LCD display.

Figure 19

Selecting the Language on the Alphanumeric Keypad

Once a valid installer code has been entered, the installer has the option of using either the Quick or Menu Program- ming mode to enter data into the panel. Each method is explained below.

Figure 20

Selecting the Programming Mode with the Alphanumeric Keypad

Quick Programming Mode

Using the Quick Programming mode, you can easily go directly to any Cmd Loc (Blocks 1 - 10 only; the Installer Commands, Block 0, are not available in Quick program- ming mode). This allows you to view or edit any of the data programmed into the panel.

The Alphanumeric display will show the Block Number (1

-10) and Programmed Data (varies by location) on the top line of the display, with the Command Location (var- ies by Block) shown on the bottom line.

Figure 21

Reading Programming Data on the Alphanumeric Keypad

The [Bypass], [Home], and [Cancel] keys are used to move between fields and to edit the data in each field, as outlined previously.

Menu Programming Mode

The Menu Programming mode uses menu options and descriptions to guide you easily through the panel pro- gramming. You can scroll through the Blocks by press- ing the [Bypass] key or go directly to any Block by press- ing the desired key (0 - 10), followed by the [Home] key.

The same three keys ([Bypass], [Home], and [Cancel]) are used in the Menu Programming mode, with slight variations.

Programming With an Alpha Keypad (cont.)

Key

Function

[Bypass]

Used to scroll through the different Menu op-

 

tions and levels.

[Home]

If the PRG> prompt is displayed, this key will

 

write the data currently displayed to memory

 

and increment to the next program position.

 

If the Menu has additional options in sub-

 

menus, this key will move to the next sub-

 

menu.

[Cancel]

Cancel the operation, if the data has not been

 

written to memory. If you are in a sub-menu,

 

this key will back up one level.

CAUTION: Pressing and holding the Cancel key for 2 seconds will Exit Programming Mode.

Programming With an Icon Keypad

The display on the keypad consists of a 3-digit display for showing numbers (Blocks, Cmd Locs, and Data) and fixed text for indicating the type of data displayed.

Figure 22

Reading Command Location on the Icon Keypad

Figure 23

Displaying Block Data on the Icon Keypad

Data will be displayed using only the digits required.

Figure 24

Viewing Program Data on the Icon Keypad

The [Bypass], [Home], and [Cancel] keys are used to move between fields and to edit the data in each field, as outlined previously.

10

Image 14
Contents Installation Instructions Page Table of Contents Country Specific Compliance Information Sierra Accessory LoadingAH Requirements for Backup SingaporeMounting the Panel Panel Setup and InstallationIntroduction Earth GroundWiring Knock-outs Top Sierra Accessory Loading Backup BatteryAH Requirements for Backup AC PowerSierra Accessory Wiring Distances Keypad WiringKeypad Wiring Output TerminalsOn-Board Relay Terminals TB2 AccessoriesZone Terminals S5050 Relay/Event Memory ModuleS5058 Zone Expansion Module SN961 SpreadNet Keyfob SN915-BUS SpreadNet ReceiverSN990/991 SpreadNet Keypad/Remote Digital Communicator ConnectionsTerminal Connections Programming the PanelRemote Programming RPS Value Press Home to activate the RPS featureProgramming With an LED Keypad Zone LEDs Cmd Loc Data ValueProgramming With an Alpha Keypad Quick Programming ModeMenu Programming Mode Programming With an Icon KeypadEvent Memory Installer Mode Options, BlockInstaller Walk-Test Exit Delay Test Bypass 0 Home CancelEntry Delay Test Battery TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Zone Response Time Zones 1 Chime Enable ZonesZone Bypass Enable Zones Audible Cadence Zones 1Block 3 Armed System Programming 4X Exit Delay Extension Enable Comments Options Quick Bypass Enable CommentsHome Arm Exit Delay Enable Low Battery Arming Comments OptionsAuto-Disarming Enable Day of Week Auto-Arming Enable AreaAuto-Disarming Enable Area Comments Swinger Alarm Lockout Limit CommentsSoak Mode Learning Period Duration Days Sounder Turn-On Delay Following Alarm Seconds CommentsStrobe/Siren Disable with Low Battery Comments Options Duress Active Only When Area ArmedSounder Bell Test Enable By Area Comments Keypad Tamper Switch Enable By Address Keypad #External Bell Reverse Enable Comments Options Home Arming Enable Comments OptionsBlock 4 Digital Communicator Programming Account #5 Account #3Account #4 Account #6Alarm Dialing Delay Seconds Comments RPS Callback Enable CommentsKeypad RPS Enable Comments Hour Zone Dial Delay Comments OptionsSpreadNet Transmitter Low Battery Report Routing Comments Power Supply Report RoutingInstaller Programming Report Routing Comments Keypad and Accessory Tamper Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Trouble Zones 1 Comments Report Code, Restoral Zones 1Report Code, Zone Bypass Zones 1 Comments Report Code, Tamper Zones 1Report Code, AC Power Restoral Report Code, Cancel Users 1 User #Report Code, AC Power Loss Report Code, Low BatteryReport Code, Ground Fault Report Code, Installer Programming StartReport Code, Installer Programming Complete Report Code, Ground Fault RestoralReport Code, Accessory Tamper Report Code, SpreadNet Keypad/Keyfob Low BatteryReport Code, SpreadNet Keypad/Keyfob Low Battery Restoral Report Code, Accessory Tamper RestoralBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Timer Count On Board Relay Exit Delay TerminatorTimer Units On Board Relay Timer Units Remm #1, Relay #1Timer Units Remm #8, Relay #2 Timer Units Remm #2, Relay #1Timer Count Remm #2, Relay #1 Timer Count Remm #2, Relay #2Timed Relay Closing Timer #1 Minutes Timed Relay Closing Timer #1 Day of WeekTimed Relay Closing Timer #1 Hours Timed Relay Closing Timer #2 Day of WeekBlock 8 SpreadNet Programming Block 9 Partition Area ProgrammingKeypad Assignments to Areas Keypads 1 Area Access by User Number User # 1First to Open/Last to Close Enable Comments Options Area Assignments SpreadNet Keypads 1User Codes User # 1 Area Access SN Keyfob/Remote # 1Block 10 User Code Programming User Codes User Codes Comments