Sierra S5832SG installation instructions Table of Contents

Page 3

Table of Contents

Compliance and Regulatory Information

i

Installing and Connecting the Control Panel

1 - 5

Sierra S5832SG PC Board Layout

1

Mounting the Panel

1 - 2

Panel Setup and Installation

1

Earth Ground

1

Mounting the Enclosures

2

S5832S Enclosure (Small)

2

S5832 Enclosure (Large)

2

Backup Battery

3

Sierra Accessory Loading

3

AH Requirements for Backup

3

Determining Standby Battery Requirements

3

AC Power

3

Output Terminals

4

External Bell Supervision

4

Keypad Wiring

4

Sierra Accessory Wiring Distances

4

Keypad Addressing

5

Connecting an Auxiliary Keypad (J8)

5

Zone Terminals

5

On-Board Relay Terminals (TB2)

5

Accessories

5 - 7

S5050 Relay/Event Memory Module

5 - 6

Switch Settings

6

Switch Configuration

6

S5058 Zone Expansion Module

6

ZEM Addressing

6

SN915-BUS SpreadNet Receiver

7

SN990/991 SpreadNet Keypad/Remote

7

SN961 SpreadNet Keyfob

7

Digital Communicator

7 - 8

Removing/Installing the Digital Communicator

7

Digital Communicator Terminal Connections

7 - 8

Terminal Connections

8

Programming the Panel

8 - 10

Remote Programming (RPS)

8

Direct Connect

8

Keypad Activated RPS

8 - 9

Programming With an LED Keypad

9

Programming With an Alphanumeric Keypad

1 0

Quick Programming Mode

1 0

Menu Programming Mode

1 0

Programming With an Icon Keypad

1 0

Installer Mode Options, (Block 0)

11 - 12

Installer Walk-Test

1 1

Event Memory

1 1

Event Memory Codes

1 1

Custom Messages

1 2

Test Report

1 2

Test Report with Audibles

1 2

Audible Test

1 2

Entry Delay Test

1 2

Exit Delay Test

1 2

Transmit Walk-Test Queue Reports

1 2

RPS Callback

1 2

Battery Test

1 2

Programming Summary

13 - 39

Block 1: Code Option Programming

13

- 14

Block 2: Zone Configuration Programming ...

14

- 16

Block 3: Armed System Programming

16

- 21

Block 4: Digital Communicator Programming 21 - 25

Block 5: Reporting Digits Programming

25

- 29

Block 6: Real Time Clock Programming

3 0

Block 7: Auxiliary Devices Programming

31

- 34

Block 8: SpreadNet Programming

3 5

Block 9: Partition (Area) Programming

35

- 37

Block 10: User Code Programming

37

- 39

Image 3
Contents Installation Instructions Page Table of Contents Singapore Sierra Accessory LoadingAH Requirements for Backup Country Specific Compliance InformationEarth Ground Panel Setup and InstallationIntroduction Mounting the PanelWiring Knock-outs Top AC Power Backup BatteryAH Requirements for Backup Sierra Accessory LoadingOutput Terminals Keypad WiringKeypad Wiring Sierra Accessory Wiring DistancesS5050 Relay/Event Memory Module AccessoriesZone Terminals On-Board Relay Terminals TB2S5058 Zone Expansion Module Digital Communicator Connections SN915-BUS SpreadNet ReceiverSN990/991 SpreadNet Keypad/Remote SN961 SpreadNet KeyfobProgramming the Panel Remote Programming RPSTerminal Connections Zone LEDs Cmd Loc Data Value Press Home to activate the RPS featureProgramming With an LED Keypad ValueProgramming With an Icon Keypad Quick Programming ModeMenu Programming Mode Programming With an Alpha KeypadInstaller Mode Options, Block Installer Walk-TestEvent Memory Battery Test Bypass 0 Home CancelEntry Delay Test Exit Delay TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Audible Cadence Zones 1 Chime Enable ZonesZone Bypass Enable Zones Zone Response Time Zones 1Block 3 Armed System Programming Low Battery Arming Comments Options Quick Bypass Enable CommentsHome Arm Exit Delay Enable 4X Exit Delay Extension Enable Comments OptionsSwinger Alarm Lockout Limit Comments Auto-Arming Enable AreaAuto-Disarming Enable Area Comments Auto-Disarming Enable Day of WeekDuress Active Only When Area Armed Sounder Turn-On Delay Following Alarm Seconds CommentsStrobe/Siren Disable with Low Battery Comments Options Soak Mode Learning Period Duration DaysHome Arming Enable Comments Options Keypad Tamper Switch Enable By Address Keypad #External Bell Reverse Enable Comments Options Sounder Bell Test Enable By Area CommentsBlock 4 Digital Communicator Programming Account #6 Account #3Account #4 Account #5Hour Zone Dial Delay Comments Options RPS Callback Enable CommentsKeypad RPS Enable Comments Alarm Dialing Delay Seconds CommentsKeypad and Accessory Tamper Report Routing Comments Power Supply Report RoutingInstaller Programming Report Routing Comments SpreadNet Transmitter Low Battery Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Tamper Zones 1 Report Code, Restoral Zones 1Report Code, Zone Bypass Zones 1 Comments Report Code, Trouble Zones 1 CommentsReport Code, Low Battery Report Code, Cancel Users 1 User #Report Code, AC Power Loss Report Code, AC Power RestoralReport Code, Ground Fault Restoral Report Code, Installer Programming StartReport Code, Installer Programming Complete Report Code, Ground FaultReport Code, Accessory Tamper Restoral Report Code, SpreadNet Keypad/Keyfob Low BatteryReport Code, SpreadNet Keypad/Keyfob Low Battery Restoral Report Code, Accessory TamperBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Timer Units Remm #1, Relay #1 Exit Delay TerminatorTimer Units On Board Relay Timer Count On Board RelayTimer Count Remm #2, Relay #2 Timer Units Remm #2, Relay #1Timer Count Remm #2, Relay #1 Timer Units Remm #8, Relay #2Timed Relay Closing Timer #2 Day of Week Timed Relay Closing Timer #1 Day of WeekTimed Relay Closing Timer #1 Hours Timed Relay Closing Timer #1 MinutesBlock 9 Partition Area Programming Block 8 SpreadNet ProgrammingArea Assignments SpreadNet Keypads 1 Area Access by User Number User # 1First to Open/Last to Close Enable Comments Options Keypad Assignments to Areas Keypads 1Area Access SN Keyfob/Remote # 1 Block 10 User Code ProgrammingUser Codes User # 1 User Codes User Codes Comments