Report Routing (Zones 1 - 32)
Cmd Loc | 116 | 117 | 118 | 119 | 120 | 121 | 122 | 123 |
Zone # | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Cmd Loc | 124 | 125 | 126 | 127 | 128 | 129 | 130 | 131 |
Zone # | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Cmd Loc | 132 | 133 | 134 | 135 | 136 | 137 | 138 | 139 |
Zone # | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Cmd Loc | 140 | 141 | 142 | 143 | 144 | 145 | 146 | 147 |
Zone # | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 |
Default | 2 (All CL) |
|
|
|
|
|
| |
Range | 1 - 5 (All CL) |
|
|
|
|
|
Keypad Medical, Police, and Fire Report Routing
Cmd Loc 148
Default 2
Range 1 - 5
Duress Report Routing
Cmd Loc 149
Default 2
Range 1 - 5
Opening / Closing Report Routing
Cmd Loc 150
Default 2
Range 1 - 5
Test Report Routing
Cmd Loc 151
Default 2
Range 1 - 5
Power Supply Report Routing
Cmd Loc 152
Default 2
Range 1 - 5
Phone Line Trouble Report Routing
Cmd Loc | 153 |
Default | 2 |
Range | 1 - 5 |
Kidwatch Check-In Fail Report Routing
Cmd Loc | 154 |
Default | 2 |
Range | 1 - 5 |
Block 4 - Digital Communicator Programming (cont.)
CommentsOptions:
These locations determine the report routing | 1 | Disable Reports | |
for alarms, bypasses, troubles, tampers, | 2 | Receiver 1 | Only |
restorals, and cancel reports on all zones. | 3 | Receiver 2 | Only |
| 4 | Receivers 1 and 2 | |
| 5 | Receiver 1, with | |
|
| Receiver 2 as Back- | |
|
| up, Alternating |
Comments
Report routing for soft zone alarms, if soft zones are enabled (Block 2, CL 155 - 157).
Comments
Report routing for all duress codes. Areas are indicated by the account number.
Comments
Report routing for opening and closing re- ports, if enabled.
Comments
Report routing for test reports.
Comments
Report routing for AC power fail, low battery, and the respective restoral reports.
Comments
Report routing for phone line cut or comm fail reports.
Comments
If Kidwatch is enabled and the Kidwatch code is not entered during the Kidwatch window (Block 6, CL 006 - 009), a report will be sent.
Installer Programming Report Routing | Comments |
Cmd Loc
Default
Range
155
2
1 - 5
Report routing for installer programming start and end reports (see Block 5, CL 135 - 138).
Bell Supervision Trouble Report Routing | Comments |
Cmd Loc
Default
Range
156
2
1 - 5
Report routing for external bell supervision trouble and restoral reports.
SpreadNet Transmitter Low Battery Report Routing Comments
Cmd Loc
Default
Range
157
2
1 - 5
Report routing for all SpreadNet transmitters low battery and restoral reports.
Keypad and Accessory Tamper Report Routing | Comments |
Cmd Loc
Default
Range
158
2
1 - 5
Report routing for all tamper and restoral re- ports associated with keypads and accesso- ries connected to the system.