Block 3 - Armed System Programming (cont.)
Quick Bypass Enable | Comments | ||
Cmd Loc | 006 |
| If enabled, quick bypass allows any user to bypass zones |
Default | 1 |
| without entering a user code. To bypass a zone, press the |
Range | 1 - 2 |
| [Bypass] key followed by the |
|
|
| bypassed. |
|
|
|
Options:
1No
2 Yes
Home Arm Exit Delay Enable
Cmd Loc | 007 |
Default | 1 |
Range | 1 - 2 |
|
|
Comments | Options: | |
If enabled, the exit delay (Block 2, CL 003) will start when a | 1 | No |
user presses and holds the [Home] key for two seconds. If | 2 | Yes |
disabled, the exit delay will be ignored and the system will |
|
|
home arm instantly. |
|
|
4X Exit Delay Extension Enable | Comments | Options: |
Cmd Loc
Default
Range
008
2
1 - 2
If enabled, the exit delay (Block 2, CL 003) will restart if the | 1 | No |
delay zone is faulted a second or subsequent time during | 2 | Yes |
the exit delay. The exit delay may be restarted up to 4 times. |
|
|
| Comments | Options: |
Cmd Loc
Default
Range
009
2
1 - 2
If enabled, all sounders (internal and external) will chirp for | 1 | No |
three seconds at the start of the entry delay (Block 2, CL | 2 | Yes |
001 or 002). |
|
|
Low Battery Arming | Comments | Options: |
Cmd Loc
Default
Range
010
2
1 - 2
If enabled, allows the system to be armed even if the back- | 1 | No |
up battery is low. | 2 | Yes |
Keypad Buzzer During Exit Delay | Comments | Options: |
Cmd Loc
Default
Range
011
2
1 - 2
If enabled, the keypad buzzer sounds during the exit delay. | 1 | No |
The keypad buzzer rate is faster during the last 10 seconds | 2 | Yes |
of the exit delay. |
|
|
Keypad Buzzer During Entry Delay
Cmd Loc | 012 |
Default | 2 |
Range | 1 - 2 |
|
|
Comments
If enabled, the keypad buzzer sounds during the entry de- lay. The keypad buzzer rate is faster during the last 10 seconds of the entry delay.
Options:
1No
2 Yes
Keypad LED Status
Cmd Loc | 013 |
Default | 1 |
Range | 1 - 3 |
|
|
Comments
This option controls the zone and status displays of the LED keypad.
NOTE: The Power and Arm LEDs on all keypads oper- ate the same.
Options:
1Always display arm and zone status
2 Status always on while disarmed. If armed, status displayed for 30 secs.
3 Display arm and zone status for 30 seconds following User Code entry.
|
|
|
| ||
Zones: | 1 - 8 |
| 9 - 16 | 17 - 24 | 25 - 32 |
Cmd Loc | 014 |
| 015 | 016 | 017 |
Default | 0 |
| 0 | 0 | 0 |
Range | 0 - 255 |
| 0 - 255 | 0 - 255 | 0 - 255 |
|
|
|
|
|
|
Comments
If programmed for
If the system is divided into areas, both zones in alarm must be within the same area.
NOTE: Fire, delay, and keyswitch zones are ignored if placed on the
Options:
0 | Disabled |
|
|
| |
1 | Zone 1 9 17 25 | ||||
2 | Zone | 2 | 10 | 18 | 26 |
4 | Zone | 3 | 11 | 19 | 27 |
8 | Zone | 4 | 12 | 20 | 28 |
16 | Zone | 5 | 13 | 21 | 29 |
32 | Zone | 6 | 14 | 22 | 30 |
64 | Zone | 7 | 15 | 23 | 31 |
128 | Zone | 8 | 16 | 24 | 32 |
Double-Knock List
Zones: | 1 - 8 | 9 - 16 | 17 - 24 | 25 - 32 |
Cmd Loc | 018 | 019 | 020 | 021 |
Default | 0 | 0 | 0 | 0 |
Range | 0 - 255 | 0 - 255 | 0 - 255 | 0 - 255 |
|
|
|
|
|
Comments
Zones listed here must be violated twice (or any two zones must be faulted) within
a
If the system is divided into areas, the alarms must be within the same area.
NOTE: Fire, delay, and keyswitch zones are ignored if placed on this list.
Options:
0 | Disabled |
|
| |
1 | Zone 1 9 17 25 | |||
2 | Zone | 2 | 10 18 | 26 |
4 | Zone | 3 | 11 19 | 27 |
8 | Zone | 4 | 12 20 | 28 |
16 | Zone | 5 | 13 21 | 29 |
32 | Zone | 6 | 14 22 | 30 |
64 | Zone | 7 | 15 23 | 31 |
128 | Zone | 8 | 16 24 | 32 |