Sierra S5832SG Quick Bypass Enable Comments, Home Arm Exit Delay Enable, Keypad LED Status

Page 21

Block 3 - Armed System Programming (cont.)

Quick Bypass Enable

Comments

Cmd Loc

006

 

If enabled, quick bypass allows any user to bypass zones

Default

1

 

without entering a user code. To bypass a zone, press the

Range

1 - 2

 

[Bypass] key followed by the 2-digit code for the zone to be

 

 

 

bypassed.

 

 

 

Options:

1No

2 Yes

Home Arm Exit Delay Enable

Cmd Loc

007

Default

1

Range

1 - 2

 

 

Comments

Options:

If enabled, the exit delay (Block 2, CL 003) will start when a

1

No

user presses and holds the [Home] key for two seconds. If

2

Yes

disabled, the exit delay will be ignored and the system will

 

 

home arm instantly.

 

 

4X Exit Delay Extension Enable

Comments

Options:

Cmd Loc

Default

Range

008

2

1 - 2

If enabled, the exit delay (Block 2, CL 003) will restart if the

1

No

delay zone is faulted a second or subsequent time during

2

Yes

the exit delay. The exit delay may be restarted up to 4 times.

 

 

Chirp-Alert on Exit Fail

Comments

Options:

Cmd Loc

Default

Range

009

2

1 - 2

If enabled, all sounders (internal and external) will chirp for

1

No

three seconds at the start of the entry delay (Block 2, CL

2

Yes

001 or 002).

 

 

Low Battery Arming

Comments

Options:

Cmd Loc

Default

Range

010

2

1 - 2

If enabled, allows the system to be armed even if the back-

1

No

up battery is low.

2

Yes

Keypad Buzzer During Exit Delay

Comments

Options:

Cmd Loc

Default

Range

011

2

1 - 2

If enabled, the keypad buzzer sounds during the exit delay.

1

No

The keypad buzzer rate is faster during the last 10 seconds

2

Yes

of the exit delay.

 

 

Keypad Buzzer During Entry Delay

Cmd Loc

012

Default

2

Range

1 - 2

 

 

Comments

If enabled, the keypad buzzer sounds during the entry de- lay. The keypad buzzer rate is faster during the last 10 seconds of the entry delay.

Options:

1No

2 Yes

Keypad LED Status

Cmd Loc

013

Default

1

Range

1 - 3

 

 

Comments

This option controls the zone and status displays of the LED keypad.

NOTE: The Power and Arm LEDs on all keypads oper- ate the same.

Options:

1Always display arm and zone status

2 Status always on while disarmed. If armed, status displayed for 30 secs.

3 Display arm and zone status for 30 seconds following User Code entry.

Cross-Zoning List

 

 

 

Zones:

1 - 8

 

9 - 16

17 - 24

25 - 32

Cmd Loc

014

 

015

016

017

Default

0

 

0

0

0

Range

0 - 255

 

0 - 255

0 - 255

0 - 255

 

 

 

 

 

 

Comments

If programmed for cross-zoning, any two of the zones listed here must be violated while armed in order for an alarm condition to register.

If the system is divided into areas, both zones in alarm must be within the same area.

NOTE: Fire, delay, and keyswitch zones are ignored if placed on the cross-zone list.

Options:

0

Disabled

 

 

 

1

Zone 1 9 17 25

2

Zone

2

10

18

26

4

Zone

3

11

19

27

8

Zone

4

12

20

28

16

Zone

5

13

21

29

32

Zone

6

14

22

30

64

Zone

7

15

23

31

128

Zone

8

16

24

32

Double-Knock List

Zones:

1 - 8

9 - 16

17 - 24

25 - 32

Cmd Loc

018

019

020

021

Default

0

0

0

0

Range

0 - 255

0 - 255

0 - 255

0 - 255

 

 

 

 

 

Comments

Zones listed here must be violated twice (or any two zones must be faulted) within

a30-second period in order for an alarm condition to register.

If the system is divided into areas, the alarms must be within the same area.

NOTE: Fire, delay, and keyswitch zones are ignored if placed on this list.

Options:

0

Disabled

 

 

1

Zone 1 9 17 25

2

Zone

2

10 18

26

4

Zone

3

11 19

27

8

Zone

4

12 20

28

16

Zone

5

13 21

29

32

Zone

6

14 22

30

64

Zone

7

15 23

31

128

Zone

8

16 24

32

17

Image 21
Contents Installation Instructions Page Table of Contents AH Requirements for Backup Sierra Accessory LoadingCountry Specific Compliance Information SingaporeIntroduction Panel Setup and InstallationMounting the Panel Earth GroundWiring Knock-outs Top AH Requirements for Backup Backup BatterySierra Accessory Loading AC PowerKeypad Wiring Keypad WiringSierra Accessory Wiring Distances Output TerminalsZone Terminals AccessoriesOn-Board Relay Terminals TB2 S5050 Relay/Event Memory ModuleS5058 Zone Expansion Module SN990/991 SpreadNet Keypad/Remote SN915-BUS SpreadNet ReceiverSN961 SpreadNet Keyfob Digital Communicator ConnectionsProgramming the Panel Remote Programming RPSTerminal Connections Programming With an LED Keypad Press Home to activate the RPS featureValue Zone LEDs Cmd Loc Data ValueMenu Programming Mode Quick Programming ModeProgramming With an Alpha Keypad Programming With an Icon KeypadInstaller Mode Options, Block Installer Walk-TestEvent Memory Entry Delay Test Bypass 0 Home CancelExit Delay Test Battery TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Zone Bypass Enable Zones Chime Enable ZonesZone Response Time Zones 1 Audible Cadence Zones 1Block 3 Armed System Programming Home Arm Exit Delay Enable Quick Bypass Enable Comments4X Exit Delay Extension Enable Comments Options Low Battery Arming Comments OptionsAuto-Disarming Enable Area Comments Auto-Arming Enable AreaAuto-Disarming Enable Day of Week Swinger Alarm Lockout Limit CommentsStrobe/Siren Disable with Low Battery Comments Options Sounder Turn-On Delay Following Alarm Seconds CommentsSoak Mode Learning Period Duration Days Duress Active Only When Area ArmedExternal Bell Reverse Enable Comments Options Keypad Tamper Switch Enable By Address Keypad #Sounder Bell Test Enable By Area Comments Home Arming Enable Comments OptionsBlock 4 Digital Communicator Programming Account #4 Account #3Account #5 Account #6Keypad RPS Enable Comments RPS Callback Enable CommentsAlarm Dialing Delay Seconds Comments Hour Zone Dial Delay Comments OptionsInstaller Programming Report Routing Comments Power Supply Report RoutingSpreadNet Transmitter Low Battery Report Routing Comments Keypad and Accessory Tamper Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Zone Bypass Zones 1 Comments Report Code, Restoral Zones 1Report Code, Trouble Zones 1 Comments Report Code, Tamper Zones 1Report Code, AC Power Loss Report Code, Cancel Users 1 User #Report Code, AC Power Restoral Report Code, Low BatteryReport Code, Installer Programming Complete Report Code, Installer Programming StartReport Code, Ground Fault Report Code, Ground Fault RestoralReport Code, SpreadNet Keypad/Keyfob Low Battery Restoral Report Code, SpreadNet Keypad/Keyfob Low BatteryReport Code, Accessory Tamper Report Code, Accessory Tamper RestoralBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Timer Units On Board Relay Exit Delay TerminatorTimer Count On Board Relay Timer Units Remm #1, Relay #1Timer Count Remm #2, Relay #1 Timer Units Remm #2, Relay #1Timer Units Remm #8, Relay #2 Timer Count Remm #2, Relay #2Timed Relay Closing Timer #1 Hours Timed Relay Closing Timer #1 Day of WeekTimed Relay Closing Timer #1 Minutes Timed Relay Closing Timer #2 Day of WeekBlock 9 Partition Area Programming Block 8 SpreadNet ProgrammingFirst to Open/Last to Close Enable Comments Options Area Access by User Number User # 1Keypad Assignments to Areas Keypads 1 Area Assignments SpreadNet Keypads 1Area Access SN Keyfob/Remote # 1 Block 10 User Code ProgrammingUser Codes User # 1 User Codes User Codes Comments