Sierra S5832SG Report Code, Opening Users 1 User #, Report Code, Closing Users 1 User #

Page 31

Block 5 - Reporting Digits Programming (cont.)

Report Code, Opening (Users 1 - 60)

 

User #:

1 - 15

16 - 30

31 - 45

46 - 60

Cmd Loc

095

096

097

098

Default

1

1

1

1

Range

0 - 15

0 - 15

0 - 15

0 - 15

 

 

 

 

 

Comments

The opening report code is a single-digit code. For two-digit reporting formats, the relative user number (1 - 15) is sent as the second digit. Program the specific Cmd Loc with 0 to disable reporting. Disabling a Cmd Loc disables reporting for all users associated with that location.

Report Code, Closing (Users 1 - 60)

 

User #:

1 - 15

16 - 30

31 - 45

46 - 60

Cmd Loc

099

100

101

102

Default

1

1

1

1

Range

0 - 15

0 - 15

0 - 15

0 - 15

 

 

 

 

 

Comments

The closing report code is a single-digit code. For two-digit reporting formats, the relative user number (1 - 15) is sent as the second digit. Program the specific Cmd Loc with 0 to disable reporting. Disabling a Cmd Loc disables reporting for all users associated with that location.

Report Code, Cancel (Users 1 - 60)

 

User #:

1 - 15

16 - 30

31 - 45

46 - 60

Cmd Loc

103

104

105

106

Default

0

0

0

0

Range

0 - 15

0 - 15

0 - 15

0 - 15

 

 

 

 

 

Comments

The cancel report code is a single-digit code. For two-digit reporting for- mats, the relative user number (1 - 15) is sent as the second digit. Program the specific Cmd Loc with 0 to disable reporting. Disabling a Cmd Loc disables reporting for all users associated with that location.

Report Code, Exit Fail Alarm (Zones 1 - 32) Zones: 1 - 8 9 - 16 17 - 24 25 - 32

Cmd Loc

107

108

109

110

Default

0

0

0

0

Range

0 - 15

0 - 15

0 - 15

0 - 15

Comments

The exit fail report code is a single-digit code which is sent if the exit (delay) zone remains faulted at the end of the exit delay. The alarm is generated in association with the Chirp-Alert Warning (Block 3, CL 009). For two-digit reporting formats, the relative zone number (1 - 8) is sent as the second digit. Program the specific Cmd Loc with 0 to disable reporting. Disabling a Cmd Loc disables reporting for all zones associated with that location.

Report Code, Kidwatch Check-in Failure

Comments

Cmd Loc

111

112

 

This two-digit code is sent to the central station if the Kidwatch code (user

Default

0

0

 

#11) is not entered during the Kidwatch period (Block 6, CL 006 - 009).

Range

0 - 15

(All

CL)

Disable the reporting by programming 00 into these Cmd Loc.

Report Code, AC Power Loss

Cmd Loc

113

114

 

Default

0

1

 

Range

0 - 15

(All

CL)

Comments

These two-digit codes are used to report AC power failures and restorals. Only the second digit is sent when using single-digit reporting formats.

Report Code, AC Power Restoral

Cmd Loc

115

116

 

Default

0

1

 

Range

0 - 15

(All

CL)

Report Code, Low Battery

Cmd Loc

117

118

 

Default

0

1

 

Range

0 - 15

(All

CL)

Comments

These two-digit report codes will be sent to indicate a low battery condition or restoral report. When using single-digit reporting formats, only the sec- ond digit will be sent.

Report Code, Low Battery Restoral

Cmd Loc

119

120

 

Default

0

1

 

Range

0 - 15

(All CL)

Report Code, Test

Cmd Loc

121

122

 

Default

0

1

 

Range

0 - 15

(All CL)

Comments

This two-digit report code will be sent to indicate a system test. When using single-digit reporting formats, only the second digit is sent.

Report Code, Failure to Report (Comm Fail)

Cmd Loc

123

124

 

Default

0

0

 

Range

0 - 15

(All

CL)

Comments

These two-digit report codes will be sent to indicate a comm fail (failure to report) condition. The reports are also sent to indicate a comm fail restoral. Only the second digit is sent when using single-digit reporting formats.

Report Code, Fail to Report (Comm Fail) Restoral

Cmd Loc

125

126

 

Default

0

0

 

Range

0 - 15

(All CL)

Report Code, Primary Phone Line Cut

Cmd Loc

127

128

 

Default

0

0

 

Range

0 - 15

(All Locations)

Comments

These two-digit codes are sent when the system detects a primary or secondary phone line cut, or their respective restorals. When using single- digit reporting formats, only the second digit is sent.

27

Image 31
Contents Installation Instructions Page Table of Contents Singapore Sierra Accessory LoadingAH Requirements for Backup Country Specific Compliance InformationEarth Ground Panel Setup and InstallationIntroduction Mounting the PanelWiring Knock-outs Top AC Power Backup BatteryAH Requirements for Backup Sierra Accessory LoadingOutput Terminals Keypad WiringKeypad Wiring Sierra Accessory Wiring DistancesS5050 Relay/Event Memory Module AccessoriesZone Terminals On-Board Relay Terminals TB2S5058 Zone Expansion Module Digital Communicator Connections SN915-BUS SpreadNet ReceiverSN990/991 SpreadNet Keypad/Remote SN961 SpreadNet KeyfobRemote Programming RPS Programming the PanelTerminal Connections Zone LEDs Cmd Loc Data Value Press Home to activate the RPS featureProgramming With an LED Keypad ValueProgramming With an Icon Keypad Quick Programming ModeMenu Programming Mode Programming With an Alpha KeypadInstaller Walk-Test Installer Mode Options, BlockEvent Memory Battery Test Bypass 0 Home CancelEntry Delay Test Exit Delay TestBlock 1 Code Option Programming Block 2 Zone Configuration Programming Audible Cadence Zones 1 Chime Enable ZonesZone Bypass Enable Zones Zone Response Time Zones 1Block 3 Armed System Programming Low Battery Arming Comments Options Quick Bypass Enable CommentsHome Arm Exit Delay Enable 4X Exit Delay Extension Enable Comments OptionsSwinger Alarm Lockout Limit Comments Auto-Arming Enable AreaAuto-Disarming Enable Area Comments Auto-Disarming Enable Day of WeekDuress Active Only When Area Armed Sounder Turn-On Delay Following Alarm Seconds CommentsStrobe/Siren Disable with Low Battery Comments Options Soak Mode Learning Period Duration DaysHome Arming Enable Comments Options Keypad Tamper Switch Enable By Address Keypad #External Bell Reverse Enable Comments Options Sounder Bell Test Enable By Area CommentsBlock 4 Digital Communicator Programming Account #6 Account #3Account #4 Account #5Hour Zone Dial Delay Comments Options RPS Callback Enable CommentsKeypad RPS Enable Comments Alarm Dialing Delay Seconds CommentsKeypad and Accessory Tamper Report Routing Comments Power Supply Report RoutingInstaller Programming Report Routing Comments SpreadNet Transmitter Low Battery Report Routing CommentsBlock 5 Reporting Digits Programming Report Code, Tamper Zones 1 Report Code, Restoral Zones 1Report Code, Zone Bypass Zones 1 Comments Report Code, Trouble Zones 1 CommentsReport Code, Low Battery Report Code, Cancel Users 1 User #Report Code, AC Power Loss Report Code, AC Power RestoralReport Code, Ground Fault Restoral Report Code, Installer Programming StartReport Code, Installer Programming Complete Report Code, Ground FaultReport Code, Accessory Tamper Restoral Report Code, SpreadNet Keypad/Keyfob Low BatteryReport Code, SpreadNet Keypad/Keyfob Low Battery Restoral Report Code, Accessory TamperBlock 6 Real Time Clock Programming Block 7 Auxiliary Devices Programming Timer Units Remm #1, Relay #1 Exit Delay TerminatorTimer Units On Board Relay Timer Count On Board RelayTimer Count Remm #2, Relay #2 Timer Units Remm #2, Relay #1Timer Count Remm #2, Relay #1 Timer Units Remm #8, Relay #2Timed Relay Closing Timer #2 Day of Week Timed Relay Closing Timer #1 Day of WeekTimed Relay Closing Timer #1 Hours Timed Relay Closing Timer #1 MinutesBlock 9 Partition Area Programming Block 8 SpreadNet ProgrammingArea Assignments SpreadNet Keypads 1 Area Access by User Number User # 1First to Open/Last to Close Enable Comments Options Keypad Assignments to Areas Keypads 1Block 10 User Code Programming Area Access SN Keyfob/Remote # 1User Codes User # 1 User Codes User Codes Comments