HP UX 11i v2 Networking Software manual Submitting Problem Information to HP

Page 70

Problem Solving

Submitting Problem Information to HP

Submitting Problem Information to HP

The following items will be very useful in having HP Support diagnose problems with your OSI products.

Result Files - The output created for all your runs of osidiag. Examples of the recommended file names are /tmp/ftam.res and

/tmp/tran.res.

OTS Configuration Files - The contents of the following files in

/etc/opt/ots/conf:

local_app

For FTAM problems only.

 

 

ots_dests

For nodes running over X.25 or NULL internet.

 

 

ots_parms

In all cases.

 

 

ots_routes

In all cases.

 

 

ots_subnets

In all cases.

 

 

remote_app

For FTAM only.

 

 

X.400 Configuration Report. If you are using X.400 and experience problems, type the following:

/opt/x400/bin/x4dump

A file called /tmp/x4dump.sh is created which can be e-mailed or put on tape.

X.25 Configuration Report. If you are using X.25 and experience problems, type the following:

/opt/x25/bin/x25stat -c /tmp/x25.cnf

Print the resulting file.

LAN Configuration Report. If you are using LAN (802.3 or FDDI) and experience problems, type the following:

/usr/sbin/lanscan /tmp/lan.cnf

Print the resulting file.

70

Chapter 2

Image 70
Contents HP 9000 Networking 32070-90031 E0597Legal Notices Copyright NoticesTrademark Notices Page Contents Problem Solving Using OSI and OTS Tools Syntax Example Recovering from otsstart FailureUpdating OTS otsupdate Printing History Page Interoperability Testing Testing Ftam Interoperability Ftam Interoperability TestingFtam Pre-Test Checklist Ftam Pre-Test ChecklistCheck the following before attempting to run the Ftam tests Ftam Interoperability Testing Ftam Connectivity TestFtam File Transfer Test Interpreting Ftam Errors Ftam Call Errors Reason Corrective ActionFtam Call Reason Corrective Action Testing Apri Interoperability Apri Pretest Checklist Apri Pre-Test ChecklistRunning Apri Tests Client Mode Running Apri Tests Server Mode Interpreting Apri Errors Apri Call Errors Reason Corrective ActionApri Call Reason Corrective Action Testing Session Interoperability Session Pre-Test Checklist Session Pre-Test ChecklistRunning Session Tests Client Mode Running Session Tests Server Mode Interpreting Session Errors Session Call Errors Reason Corrective ActionSession Call Reason Corrective Action Testing Transport Interoperability Transport Pre-Test Checklist Transport Pre-Test ChecklistRunning Transport Tests Problem persists Interpreting Transport ErrorsTransport problem corrected Transport Call Errors Reason ActionTesting LAN 802.3 or Fddi Interoperability LAN Pre-Test Checklist LAN Pre-Test ChecklistRunning LAN Tests LAN Errors Reason Action Interpreting LAN ErrorsLAN problem corrected Configuration change requiredError Reason Action Testing X.25 Interoperability Pre-Test Checklist Pre-Test ChecklistRunning X.25 Tests Problem corrected Interpreting X.25 ErrorsErrors Reason Action Recv*00B Reason and Refuse Codes Protocol Reason CodesCode Meaning Action 0x08 Reject Nsap unreachable/ Permanent Reason and Refuse Codes Local node may not be compatible with that Osiadmin F0-FF Session Refuse Codes Session Refuse CodesCode Meaning To Create a Result File Problem Solving Basic Steps Interpreting Errors Interpreting ErrorsWhere Action Checking System Status Status CheckStatus Check Running Verification Tests Link VerificationService Verification OTS Transport VerificationRunning Verification Tests Troubleshooting Methods Collecting Troubleshooting DataType Troubleshooting Method Error Tracing and Logging through Opt/ots/bin/osidiagTracing and Logging User Applications Service/Layer Entities to LogLogging and Tracing Entities Fddi Otsdests Common Mistakes Common Configuration MistakesOtssubnets Common Mistakes Localapp Common Mistakes Otsparms Common MistakesRemoteapp Common Mistakes Subsystem OTS Common Logged ErrorsError Description Subsystem AcsepresSubsystem Transport Subsystem Network Submitting Problem Information to HP Using OSI and OTS Tools Osiadmin RFC1006 Configure Using osiconf Managing Your ConfigurationTroubleshooting Using osiconfchk Tests Provided by osidiag OSI DiagnosticsComponent Test Fddi Osistart Command Starting and Stopping OSIOsistat Command Stopping OSISyntax Starting OTS otsstartExample Recovering from otsstart Failure Checking OTS Status otsstat OTS Updating OTS otsupdate Dynamic Routing Commands End System CommandsIntermediate System Commands OtsaddisArgument ES/IS Command ParametersES/IS Parameters ParameterES/IS Command Options Option DescriptionRoute Commands Dynamic Routing CommandsRoute Command Parameters Dynamic Route CommandsRoute Command Options Route Command OptionsNsap Commands Argument DescriptionOtsshownsaps Index ApriIndex