Sterling BP1018, BP1012 installation manual Test the Interlock Switches, Checking Knife Position

Page 28

If the rotation direction is correct, the granulator is ready to use. If the rotation direction is incorrect, reverse the rotor direction as follows:

!!Warning!!

A LICENSED ELECTRICIAN must carry out this operation.

1.Disconnect and lockout the power to the machine at the incoming power source. If the disconnect is not lockable, remove the fuses.

2.Reverse any two of the three power line conductors to the machine. If there is more than one motor on the machine and only one is turning in the wrong direction, reverse any two of the three line conductors at the overload relay for that motor.

3.Unlock the power and switch the electrical disconnect switch to “ON”. (Replace the fuses if necessary.)

4.Re-check the rotation direction of the motors.

4-4-3 Test the Interlock Switches

With the cutting chamber and screen cradle closed and power On, perform the following tests:

1.Push the start button to start the granulator.

2.Retract the screen cradle interlock actuator screw by turning it counterclockwise. Make sure that the end of the actuator screw is visible and clear of any contact. The granulator should stop.

3.If the machine continues to run, turn off and lockout the power.

4.Have the electrician check the interlock switch on the screen cradle to correct the malfunction.

5.If necessary, engage the screen cradle interlock actuator screw.

Having completed the above procedures, close the control panel. Unlock power or return the fuses in the supply panel, turning the disconnect switch to “ON”. Pull the start button and release only when the motor has started, then check again that the rotor is turning in the correct direction.

4-4-4 Checking Knife Position

NOTE: This operation must be carried out by an operator / mechanical maintenance engineer.

Page 28 of 53

Image 28
Contents BP1000 Series Granulators Page Sterling Warranty Information Sterling Warranty Information Table of Contents Start Up and Operation Table of Figures Viii Safety Considerations Safety GuidelinesPage Guidelines for Moving the Granulator Safety ProceduresClearing a Jammed Cutting Chamber Safety Features Safety Features Fitted On the GranulatorSafety Switch Opening the GranulatorWear protective gloves when exposed to knives Sound EnclosureModel Motor Power Noise Test Method General Information Using This ManualIntroduction Safety Symbols Used in This Manual DescriptionMain Components of Standard Granulators Optional EquipmentModel Shipping Information Unpacking and InspectionEvent of Shipping Damage If the Shipment is Not CompleteReturns If the Shipment is Not CorrectUncrating Your Granulator Especially the Hopper Lifting InstallationPositioning the Granulator Electrical Connection Inserting the BinStart-Up Checks Checking the Cutting ChamberChecking Rotation Direction Removing the Screw KnobTest the Interlock Switches Checking Knife PositionChecking the Knife Gap Pre-Operational Checklist Start Up and OperationOperation Never push material into the hopper with handsMaintenance General RecommendationsDrive Belt Tension Monthly Maintenance OperationsProper Belt Tension Removal and Replacement of the Screen Belt ReplacementInspection and Adjustment of Knives Removing the ScreenPage Removing and Replacing Bed Knives Inspection of KnivesRemoval and Replacement of Rotating Blades Specifications for Re-sharpening Bed Knives Specifications for Re-sharpening Rotor Knives Bed Knife Specifications7Troubleshooting General ProblemsProblem Possible Causes Possible Remedies Electrical Problems Recommended Spare Parts List Spare PartsCutting Chamber Vertical Cross Section Cutting Chamber Longitudal Cross Section Cutting Chamber Front View Cutting Chamber Rear View Typical Wiring Diagram Contact Information Parts DepartmentService Notes Warranty