Electrical Problems |
| ||
|
|
| |
Problem | Possible Causes | Possible Remedies | |
Machine stops for no | Safety switch has stopped power | Check that the knobs that operate | |
apparent reason |
| the safety switch are tightened | |
|
|
| |
Electric motor does not | No power | Check fuses | |
start |
|
|
|
|
| Overload failure | Check amperage of electric motor |
|
|
| Check and replace |
|
| Safety switch not working |
|
|
|
| Empty cutting chamber |
|
| Cutting chamber too full |
|
Motor starts but does not | Excessive drive belt tension | Check belt tension and adjust | |
speed up or take a load |
|
| |
|
| Motor connected to power source | Reconnect correctly |
|
| incorrectly |
|
|
| Defective starter winding | Check current in each phase. If |
|
|
| substantial difference between |
|
|
| phases, contact motor manufacturer |
|
|
| |
Motor starts, but does not | Bearing excessively worn | Replace bearings | |
gain speed |
|
|
|
|
| Cutting chamber full | Empty cutting chamber |