Sterling BP1012, BP1018 installation manual Checking the Knife Gap

Page 29

Before undertaking any type of work on the machine, use a feeler gauge to check the distance between the bed knives and the rotor knives (the knife gap).

To access the cutting chamber, follow the same procedure and observe the precautionary steps given in Section 4-4-1. Before proceeding to the checks, it is advisable to block the rotor to avoid any inadvertent rotation.

Once you have safely accessed the cutting chamber, check the current distance between the bed knives and the rotor knives using a feeler gauge. (See Figure 12.)

NOTE: The distance set by the manufacturer for normal application is 0.006”-0.008” (0.15-0.20 mm). If the gap between the bed knives and the rotor knives is found to be greater than that, an adjustment must be made. (See Section 6-4: Inspection and Adjustment of Knives.)

Once you have checked the knife gap, close the hopper, secure it with the appropriate swing bolts, reinsert the bin, and close the front panel.

Figure 12: Checking the Knife Gap

Page 29 of 53

Image 29
Contents BP1000 Series Granulators Page Sterling Warranty Information Sterling Warranty Information Table of Contents Start Up and Operation Table of Figures Viii Safety Guidelines Safety ConsiderationsPage Clearing a Jammed Cutting Chamber Safety ProceduresGuidelines for Moving the Granulator Safety Features Fitted On the Granulator Safety FeaturesOpening the Granulator Safety SwitchSound Enclosure Wear protective gloves when exposed to knivesModel Motor Power Noise Test Method Introduction Using This ManualGeneral Information Description Safety Symbols Used in This ManualOptional Equipment Main Components of Standard GranulatorsModel Unpacking and Inspection Shipping InformationEvent of Shipping Damage If the Shipment is Not CompleteUncrating Your Granulator If the Shipment is Not CorrectReturns Especially the Hopper Positioning the Granulator InstallationLifting Inserting the Bin Electrical ConnectionChecking the Cutting Chamber Start-Up ChecksRemoving the Screw Knob Checking Rotation DirectionChecking Knife Position Test the Interlock SwitchesChecking the Knife Gap Start Up and Operation Pre-Operational ChecklistNever push material into the hopper with hands OperationGeneral Recommendations MaintenanceProper Belt Tension Monthly Maintenance OperationsDrive Belt Tension Belt Replacement Removal and Replacement of the ScreenRemoving the Screen Inspection and Adjustment of KnivesPage Inspection of Knives Removing and Replacing Bed KnivesRemoval and Replacement of Rotating Blades Specifications for Re-sharpening Bed Knives Bed Knife Specifications Specifications for Re-sharpening Rotor KnivesGeneral Problems 7TroubleshootingProblem Possible Causes Possible Remedies Electrical Problems Spare Parts Recommended Spare Parts ListCutting Chamber Vertical Cross Section Cutting Chamber Longitudal Cross Section Cutting Chamber Front View Cutting Chamber Rear View Typical Wiring Diagram Parts Department Contact InformationService Notes Warranty