Sterling BP1012, BP1018 Inspection and Adjustment of Knives, Removing the Screen

Page 35

4.Remove the screw knob that holds the hopper on top of the cutting chamber. Carefully lower the screen cradle assembly, resting it on the base.

5.Remove the screen, keeping it in a horizontal position. (See Figure 15.)

6.Replace the screen with a new one, tighten the screw knob, reposition the bin, and close the front panel. Unlock the power and turn the machine back on.

Figure 15: Removing the Screen

6-4 Inspection and Adjustment of Knives

NOTE: This operation must be performed by a qualified operator / mechanical maintenance technician.

Important!

Before carrying out any maintenance on the cutting chamber, the operator must wear work gloves thick enough to avoid injury to the hands while touching sharp parts or the cutting edges of the blades.

To inspect blades, remove the screen by following steps 1-5 in

Section 6-3. Then, proceed as follows:

1.Open the rear-closing panel by releasing the locking latch.

2.Pivot the in-feed hopper completely back to gain clear access to the cutting chamber, and clear any process material or foreign objects between the knives.

3.Turn the rotor slowly until the first row of rotor knives are in close proximity to the bed knife cutting edge. Turn the rotor backwards, keeping hands and fingers from directly contacting sharp knife-edges.

Page 35 of 53

Image 35
Contents BP1000 Series Granulators Page Sterling Warranty Information Sterling Warranty Information Table of Contents Start Up and Operation Table of Figures Viii Safety Guidelines Safety ConsiderationsPage Clearing a Jammed Cutting Chamber Safety ProceduresGuidelines for Moving the Granulator Safety Features Fitted On the Granulator Safety FeaturesOpening the Granulator Safety SwitchSound Enclosure Wear protective gloves when exposed to knivesModel Motor Power Noise Test Method Introduction Using This ManualGeneral Information Description Safety Symbols Used in This ManualOptional Equipment Main Components of Standard GranulatorsModel If the Shipment is Not Complete Shipping InformationUnpacking and Inspection Event of Shipping DamageUncrating Your Granulator If the Shipment is Not CorrectReturns Especially the Hopper Positioning the Granulator InstallationLifting Inserting the Bin Electrical ConnectionChecking the Cutting Chamber Start-Up ChecksRemoving the Screw Knob Checking Rotation DirectionChecking Knife Position Test the Interlock SwitchesChecking the Knife Gap Start Up and Operation Pre-Operational ChecklistNever push material into the hopper with hands OperationGeneral Recommendations MaintenanceProper Belt Tension Monthly Maintenance OperationsDrive Belt Tension Belt Replacement Removal and Replacement of the ScreenRemoving the Screen Inspection and Adjustment of KnivesPage Inspection of Knives Removing and Replacing Bed KnivesRemoval and Replacement of Rotating Blades Specifications for Re-sharpening Bed Knives Bed Knife Specifications Specifications for Re-sharpening Rotor KnivesGeneral Problems 7TroubleshootingProblem Possible Causes Possible Remedies Electrical Problems Spare Parts Recommended Spare Parts ListCutting Chamber Vertical Cross Section Cutting Chamber Longitudal Cross Section Cutting Chamber Front View Cutting Chamber Rear View Typical Wiring Diagram Parts Department Contact InformationService Notes Warranty