York DFAA installation manual List of Sections, List of Figures, List of Tables, Section I Safety

Page 1

INSTALLATION MANUAL

HIGH EFFICIENCY SEALED COMBUSTION

 

 

 

 

 

 

 

EFFICIENCY

DRUM HEAT EXCHANGER SERIES

 

RATING

 

 

CERTIFIED

MODEL: DFAA/DFAH

 

 

 

 

 

 

ISO 9001

 

 

 

 

 

 

 

 

 

 

 

 

(Oil and Gas Conversion Burner/

 

 

 

 

 

 

Management System

 

 

 

 

 

 

 

Certified Quality

Single Stage Downflow Only)

For Installation In:

 

1.

Manufactured (Mobile) Homes

 

66 - 84 MBH INPUT

 

2.

Recreational Vehicles & Park Models

(19.34 - 24.62 KW) INPUT

3.

Modular Homes & Buildings

 

 

 

 

 

 

 

 

 

LIST OF SECTIONS

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 OIL PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 VENT/COMBUSTION AIR SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . 14

SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 WIRING DIAGRAM - OIL-FIRED FURNACE . . . . . . . . . . . . . . . . . . . . 27 GAS GUN BURNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 WIRING DIAGRAM - GAS CONVERSION BURNER . . . . . . . . . . . . . . 38

LIST OF FIGURES

Label Location

. 4

Dimensions

. 5

Air Distribution Systems

. 7

Closet To Door Clearance - 5” or Greater

. 7

Furnace To Closet Door Clearance - 1” To 5”

. 7

Furnace To Closet Door Clearance - Less Than 1”

. 7

Duct Connector Dimensions

. 8

Recommended Floor Cut-out

. 8

Duct Connector Depth

. 8

Duct Connector Screw Attachment

. 8

Duct Connector Tab Attachment

. 9

Anti-Backflow Damper

. 9

Installation of Furnace

. 9

Floor Installation

10

Furnace Air Filters

11

Oil Pump

12

One-Pipe System

13

Two-Pipe System

13

Solenoid Wiring

13

Line Wiring Connections

14

Wiring for Heat Only Thermostat

14

Wiring for Electronic Heat-Cool Thermostat

14

Wiring for Standard Heat-Cool Thermostat

14

Wiring for Blend Air Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Elbow Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Combustion Air Inlet Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Combustion Air Inlet Pipe Alternate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Flue Shield Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Roof Jack Attachment to Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Standard Roof Jack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Roof Jack With Removable Crowns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Installing Roof Jack Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ceiling Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Electrode Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Oil Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Wiring Diagram for DFAA - Oil-Fired Furnace . . . . . . . . . . . . . . . . . . . . . 27 Wiring Diagram for DFAH - Oil Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Manual Shut-off Valve/Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Proper Piping Practice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Electrode Orientation and Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Wiring Diagram for DFAA - Gas Conversion Burner . . . . . . . . . . . . . . . . . 38 Wiring Diagram for DFAH - Gas Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

LIST OF TABLES

Unit Clearances to Combustibles

. 4

Timings and Settings

22

Minimum Duct Sizing For Proper Airflow

. 6

Burner Specifications

23

Round Duct Size

. 6

Filter Performance - Pressure Drop Inches W.C. and (kPa)

24

External Static Pressure Range

. 9

Blower Performance CFM

25

Filter Sizes

10

Replacement Parts - Non Electrical

26

Burner Specifications

11

Gas Line Piping Size and Length

30

Burner Rating at Elevation Above Sea Level, gph (l/m)

12

Length of Standard Pipe Threads in Inches (mm)

30

Ratings & Physical / Electrical Data

13

High Altitude Duration Chart

32

Roof Jack Options

17

Gas Burner Settings

32

Cad Cell Resistance When Sensing Flame

22

Inlet Gas Pressure Range

35

 

 

Nominal Manifold Pressure

35

SECTION I: SAFETY

This is a safety alert symbol. When you see this symbol on labels or in manuals, be alert to the potential for personal

injury.

Understand and pay particular attention to the signal words DANGER,

WARNING, or CAUTION.

DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation, which, if not

avoided may result in minor or moderate injury. It is also used to

alert against unsafe practices and hazards involving only property dam- age.

Improper installation may create a condition where the operation of the product could cause personal injury or property damage.

Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for assistance or for additional information, consult a qualified con- tractor, installer or service agency.

This product must be installed in strict compliance with the installa- tion instructions and any applicable local, state, and national codes including, but not limited to building, electrical, and mechanical codes.

107272-UIM-B-1105

Image 1
Contents For Installation Section I SafetyList of Sections List of FiguresSafety Requirements Specific Safety Rules and PrecautionsFollowing requirements to be met Inspection Combustion AIR Quality List of ContaminantsFurnace Location and Clearances Check Certifications / ApprovalsTOP Front Back Sides AIR Inlet Roof Jack DUCT1 Piping FLOOR/BOTTOMSection II Ductwork Duct system’s design and installation mustDuctwork General Information Air Distribution Systems Duckwork InstallationDuct Design Canada Clearance Requirements CanadaAir Distribution Systems Installation of Screw Attachment Duct Connector Duct ConnectorsFurnace and Air Conditioner Installations Installation of TAB Attachment Duct ConnectorsInstallation of the Furnace MBH CFMSection III Filters Blend AIR InstallationsReturn AIR Requirements Section IV OIL Piping OIL SafetyConnect Fuel Lines Effect of Elevation on OIL Burner Firing Installation and Checking of OIL PipingExample AFGSolenoid Wiring Section V Electrical PowerElectrical Power Connections ONE Pipe SystemVent and Combustion AIR Safety LOW Voltage Control Wiring ConnectionsEighteen gauge thermostat wire is highly recommended Section VI VENT/COMBUSTION AIR SystemNEW Home Installation Existing Furnace ReplacementInstallation in Snow Regions Exterior Roof Jack ExtensionConnect Roof Jack to Furnace Installing Roof Jack in RoofLocating and Cutting Roof Jack Opening Interior ExtensionsRoof Jack Adjustable Height with Complete Installation, as requiredSecure Roof Jack to Roof Interior ExtensionDfaa Models Dfah Models UIM-B-1105 Vent System Installing Ceiling RingVent Clearances Home Layout Canadian Installations1 US Installation2 Section VII Safety Controls Specifications Section Viii START-UP AdjustmentsSTART-UP and Adjust Burner Adjustment of Temperature Rise Adjustment of OIL Pump PressureIgnition System Sequence SET Combustion with InstrumentsInstall Furnace Doors Final ProcedureApplying Filter Pressure Drop to Determine System AirflowItem Number Description Dfaa ModelDfah Model Wiring Diagram for Dfaa Oil-Fired Furnace Section IX Wiring Diagram OIL-FIRED FurnaceUIM-B-1105 Wiring Diagram for Dfah Oil Furnace Unitary Products GroupSection X GAS GUN Burner Installation of Burner and ControlsPreparation of Combustion Chamber GAS PipingGAS Piping Installation Testing Piping for LeaksLocate GAS LEAKS, USE a Soap Solution Length of Pipe Nominal Diameter of Pipe in Inches mmHigh Altitude GAS Orifice Conversion GAS Orifice Conversion for Propane LPNatural GAS Sizing Furnace InputPropane GAS Gas Firing Rate Orifice Air ShutterPurging Section XI START-UP AdjustmentsCalculating the Furnace Input Natural GAS USA use the following formula to calculate the furnace input Initial Start UP Adjustment of Manifold GAS PressureChecking the GAS Pressures Inlet GAS Pressure RangeIf Furnace Fails to Operate Properly Observing Burner OperationPerformance Check Electrode Orientation and Gap Section XII Wiring Diagram GAS Conversion Burner Wiring Diagram for Dfah Gas Gun Copyright by York International Corp . All rights reserved Unitary 5005 Norman Product York Group Drive 73069