Raypak 850, 300 operating instructions Status Menu 1 Items

Page 36
Status Menu 1 Items

Status Menu 1 Items

Screen No.

Default Information Displayed

Range

Description

1

Supply

XXX ºF

-13-248 ºF

Heater outlet water temperature

Return

XXX ºF

-13-248 ºF

Heater inlet water temperature

 

2

CH Set

160 ºF

50-190 ºF

Heater outlet water setpoint for hydronic heating

Supply

XXX ºF

-13-248 ºF

Heater outlet water temperature

 

3*

Cas Set

160 ºF

50-190 ºF

Cascade (System sensor) setpoint if Master

System

XXX ºF

-13-248 ºF

System sensor temperature if Master and present

 

4

DHW Set

140 ºF

95-180 ºF

DHW Tank setpoint

DHW

XXX ºF

-13-248 ºF

DHW tank temperature (if sensor is present)

 

5

Outdoor

XXX ºF

-40-248 ºF

Outdoor air temperature (if sensor is present, otherwise off)

 

 

 

 

 

 

 

 

 

6

Flame

0.0 uA

 

Flame ionization signal

Fan Speed

0 RPM

 

Fan RPM

 

 

7

0-10V

10.0 V

 

Remote setpoint or modulation signal

 

 

 

 

 

 

 

 

8

Bus Comm No Conn

Conn/No Conn

Cascade bus connection or no connection

 

 

 

 

 

 

 

 

 

9

Power On

0h

 

Hours the heater has been powered

CH On

0h

 

Hours with a call for heat

 

 

10

DHW On

0h

 

Hours with a DHW demand

Good ignition

0x

 

Number of successful ignitions

 

 

11

Fault History

1/Fault type (last error)

 

Last fault display code

MM/DD/YYYY Day 12:00:00

 

Time of last fault

 

 

12

Fault History

2/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

13

Fault History

3/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

14

Fault History

4/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

15

Fault History

5/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

16

Fault History

6/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

17

Fault History

7/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

18

Fault History

8/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

19

Fault History

9/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

20

Fault History

10/Fault type

 

Fault diplay code

MM/DD/YYYY Day 12:00:00

 

Time of fault

 

 

* Screen 3 is displayed in Cascade Mode only

36

Image 36
Contents WHAT TO DO IF YOU SMELL GAS Do not try to light any applianceINSTALLATION & OPERATING INSTRUCTIONS Models 300, 500 & Types H & WPage CONTENTS BEFORE INSTALLATIONGENERAL SAFETY INSTALLATION WIRING DIAGRAM START-UPWARNINGS Pay Attention to These TermsBEFORE INSTALLATION Installations at ElevationProduct Receipt Model IdentificationComponent Locations General InformationGENERAL SAFETY Time/Temperature Relationships in ScaldsINSTALLATION Installation CodesIndoor Installations Outdoor InstallationsCombustion and Ventilation Air Indoor UnitsU.S. Installations1 Canadian Installations2Table F Vent/Air Inlet Termination Clearances U.S. Installations Conventional Combustion Air SupplyCombustion Air Filter Direct VentCanadian Installations Water PipingGeneral Relief Valve Installation and Piping Hydronic HeatingTemperature & Pressure Gauge Hydrostatic TestAir-Separation/ExpansionTank Three-WayValvesDomestic Hot Water Potable Water and Space Heating Gas Supply Connection Gas SupplyGas Supply Pressure Electrical Power Connections Check the Power Source Making the Electrical ConnectionsField-ConnectedControllers Field Wiring Connections Wiring the ThermostatWiring the Outdoor Sensor Wiring the Indirect SensorWiring the Cascade System Communication Bus 3.Create a hole to route the communication cables through where the dimples are in the side of the cabinet see Fig. 15, or route the wires to the rear junction box and out of the cabinet Cascade Master Pump and Sensor Wiring Cascade Follower Pump and Sensor Wiring VentingGeneral Support of Vent Stack Vent Terminal LocationConfiguration CombustionVenting Installation Tips Venting ConfigurationsVertical Venting Category Combustion Volume of Common VentingModel No Vent SizeHorizontal Through-the-WallDirect Venting CategoryFig. 21 Typical Common Venting Fig. 22 Horizontal Through-the-WallVentingInstallation TerminationModel No Approved IntakesDirect Vent-Vertical Outdoor Installation Freeze ProtectionHigh Limit - Manual Reset High Limit - Auto Reset OptionalControls Ignition Control FunctionsFlow Switch High & Low Gas Pressure Switches OptionalBlocked Vent Switch Low Water Cut-OffOptionalAdjusting the XFyre Setpoint Operating InstructionsBlocked Condensate Drain Sensor User MenuService Mode Status MenuStatus Menu 1 Items Status Menu 2 Items Installer Menu Items continued Installer Menu WIRING DIAGRAM For Your Safety START-UPPre Start-up Pre Start-upCheckPreparation Start-UpBlower Check Safety Inspection Manifold CheckFinishing Follow-UpOPERATION Lighting InstructionsPost Start-UpCheck TROUBLESHOOTING XFyre Error CodesHeater Errors Heater FaultsXFyre Fault Text Remedy FLUE / GAS PRESS F01Sensor Resistance Values Temperature SensorsResistance ohms OutdoorMAINTENANCE Suggested Minimum Maintenance SchedulePreventive Maintenance Schedule DailyWeekly Semi-AnnuallyAnnually As RequiredCombustion Chamber Coil Cleaning Instructions NIOSH stated First AidAPPENDIX Inside Air Contamination248 CMR 5.082a1 through LIMITED PARTS WARRANTY XFYRE - TYPE H and W HEAT EXCHANGER WARRANTYMODELS SCOPESTART-UPCHECKLIST FOR THE XFYRE EMISSIONS SETTINGS AND TEST INFORMATIONNominal Factory Recommended Settings GAS SUPPLY DATA
Related manuals
Manual 8 pages 63.38 Kb Manual 8 pages 12.19 Kb

300, 850 specifications

Raypak is a renowned name in the heating industry, particularly known for its high-quality pool and spa heaters. Among their extensive product line, the Raypak 850, 500, 300, 400, and 700 models stand out for their reliability, efficiency, and cutting-edge technologies. Each model is designed to cater to different needs and applications while maintaining Raypak’s commitment to performance.

The Raypak 850 is designed for larger commercial pools or residential setups requiring high output. With a powerful heat exchanger made from copper and bronze, it ensures superior heat transfer and longevity. Its digital control system provides precise temperature regulation, enhancing user experience. Moreover, it features a durable construction with weather-resistant materials, ensuring lasting performance in various environments.

The Raypak 500 model offers a balance between efficiency and compactness. It features eco-friendly technology that reduces energy consumption without sacrificing performance. The integrated thermostat allows users to maintain consistent water temperatures, making it ideal for residential pools. This model is well-regarded for its user-friendly digital display, simplifying operation and monitoring.

For those needing a more moderate capacity, the Raypak 300 is an efficient choice. It combines robust engineering with an easy-to-use interface. Its advanced ignition system improves reliability while minimizing energy waste. The Raypak 300’s compact design allows for easy installation in various spaces, making it an excellent option for smaller pools.

The Raypak 400 heats water quickly and efficiently, making it suitable for both residential pools and spas. It features a high-capacity heating system that ensures optimal performance. With a clear LED display, users can easily monitor their settings, while the integrated diagnostics provide real-time feedback for maintenance and troubleshooting.

Lastly, the Raypak 700 model is known for its versatility and robust performance. It is equipped with advanced safety features, including a high limit switch and water flow detection mechanism, to ensure safe operation. The model's energy-efficient design enhances its eco-friendliness, making it a popular choice among environmentally conscious users.

Collectively, these Raypak models exemplify superior engineering, performance, and user-friendliness. Their innovative features ensure that they meet the varied demands of pool owners while providing reliable heating solutions for leisure and relaxation. Whether for commercial or residential use, the Raypak 850, 500, 300, 400, and 700 offer unmatched quality and efficiency.