Raypak 300, 850 operating instructions General Safety, Time/Temperature Relationships in Scalds

Page 7
GENERAL SAFETY

Model No.

Heater Water Volume

(gallons)

300

2.9

500

4.2

850

5.8

Table B: Heater Water Volume

GENERAL SAFETY

To meet commercial hot water use needs, the high limit safety control on this water heater will shut off the main gas valve before the outlet temperature reaches 210°F. However, water temperatures over 125°F can cause instant severe burns or death from scalds. When supplying general purpose hot water, the rec- ommended initial setting for the temperature control is 125°F.

Safety and energy conservation are factors to be con- sidered when setting the water temperature on the thermostat. The most energy-efficient operation will result when the temperature setting is the lowest that satisfies the needs of the application.

Water temperature over 125°F can cause instant severe burns or death from scalds. Children, disabled and elderly are at highest risk of being scalded.

Feel water before bathing or showering.

Temperature limiting valves are available.

NOTE: When this heater is supplying general purpose hot water for use by individuals, a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information.

Maximum water temperatures occur just after the heater’s burner has shut off. To determine the water temperature being delivered, turn on a hot water faucet and place a thermometer in the hot water stream and read the thermometer.

CAUTION: Hotter water increases the risk of scalding! There is a hot water scald potential if the thermostat is set too high.

Water temperature over 125°F can cause instant severe burns or death from scalds.

Children, disabled, and elderly are at highest risk of being scalded.

See instruction manual before set- ting temperature at water heater.

Feel water before bathing or show- ering.

Temperature limiting valves are available, see manual.

Time/Temperature

Relationships in Scalds

The following chart details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the safest water temperature for your applications.

Water

Time to Produce Serious

Temp.

Burn

 

 

120°F

More than 5 minutes

 

 

125°F

1-1/2 to 2 minutes

 

 

130°F

About 30 seconds

 

 

135°F

About 10 seconds

 

 

140°F

Less than 5 seconds

 

 

145°F

Less than 3 seconds

 

 

150°F

About 1-1/2 seconds

 

 

155°F

About 1 second

 

 

Table courtesy of The Shriners Burn Institute

Table C: Time to Produce Serious Burn

7

Image 7
Contents Models 300, 500 & Types H & W WHAT TO DO IF YOU SMELL GASDo not try to light any appliance INSTALLATION & OPERATING INSTRUCTIONSPage WIRING DIAGRAM START-UP CONTENTSBEFORE INSTALLATION GENERAL SAFETY INSTALLATIONPay Attention to These Terms WARNINGSModel Identification BEFORE INSTALLATIONInstallations at Elevation Product ReceiptGeneral Information Component LocationsTime/Temperature Relationships in Scalds GENERAL SAFETYOutdoor Installations INSTALLATIONInstallation Codes Indoor InstallationsIndoor Units Combustion and Ventilation AirCanadian Installations2 U.S. Installations1Table F Vent/Air Inlet Termination Clearances Direct Vent U.S. InstallationsConventional Combustion Air Supply Combustion Air FilterWater Piping Canadian InstallationsGeneral Hydrostatic Test Relief Valve Installation and PipingHydronic Heating Temperature & Pressure GaugeThree-WayValves Air-Separation/ExpansionTankDomestic Hot Water Potable Water and Space Heating Gas Supply Gas Supply ConnectionGas Supply Pressure Electrical Power Connections Making the Electrical Connections Check the Power SourceField-ConnectedControllers Wiring the Thermostat Field Wiring ConnectionsWiring the Indirect Sensor Wiring the Outdoor SensorWiring the Cascade System Communication Bus 3.Create a hole to route the communication cables through where the dimples are in the side of the cabinet see Fig. 15, or route the wires to the rear junction box and out of the cabinet Cascade Master Pump and Sensor Wiring Venting Cascade Follower Pump and Sensor WiringGeneral Combustion Support of Vent StackVent Terminal Location ConfigurationVenting Configurations Venting Installation TipsVertical Venting Category Combustion Vent Size Volume ofCommon Venting Model NoFig. 22 Horizontal Through-the-WallVenting Horizontal Through-the-WallDirectVenting Category Fig. 21 Typical Common VentingApproved Intakes InstallationTermination Model NoDirect Vent-Vertical Freeze Protection Outdoor InstallationIgnition Control Functions High Limit - Manual ResetHigh Limit - Auto Reset Optional ControlsLow Water Cut-OffOptional Flow SwitchHigh & Low Gas Pressure Switches Optional Blocked Vent SwitchUser Menu Adjusting the XFyre SetpointOperating Instructions Blocked Condensate Drain SensorStatus Menu Service ModeStatus Menu 1 Items Status Menu 2 Items Installer Menu Items continued Installer Menu WIRING DIAGRAM Pre Start-upCheck For Your SafetySTART-UP Pre Start-upStart-Up PreparationBlower Check Follow-Up Safety InspectionManifold Check FinishingLighting Instructions OPERATIONPost Start-UpCheck Heater Faults TROUBLESHOOTINGXFyre Error Codes Heater ErrorsXFyre Fault Text FLUE / GAS PRESS F01 RemedyOutdoor Sensor Resistance ValuesTemperature Sensors Resistance ohmsDaily MAINTENANCESuggested Minimum Maintenance Schedule Preventive Maintenance ScheduleAs Required WeeklySemi-Annually AnnuallyNIOSH stated First Aid Combustion Chamber Coil Cleaning InstructionsInside Air Contamination APPENDIX248 CMR 5.082a1 through SCOPE LIMITED PARTS WARRANTY XFYRE - TYPE H and WHEAT EXCHANGER WARRANTY MODELSGAS SUPPLY DATA START-UPCHECKLIST FOR THE XFYREEMISSIONS SETTINGS AND TEST INFORMATION Nominal Factory Recommended Settings
Related manuals
Manual 8 pages 63.38 Kb Manual 8 pages 12.19 Kb

300, 850 specifications

Raypak is a renowned name in the heating industry, particularly known for its high-quality pool and spa heaters. Among their extensive product line, the Raypak 850, 500, 300, 400, and 700 models stand out for their reliability, efficiency, and cutting-edge technologies. Each model is designed to cater to different needs and applications while maintaining Raypak’s commitment to performance.

The Raypak 850 is designed for larger commercial pools or residential setups requiring high output. With a powerful heat exchanger made from copper and bronze, it ensures superior heat transfer and longevity. Its digital control system provides precise temperature regulation, enhancing user experience. Moreover, it features a durable construction with weather-resistant materials, ensuring lasting performance in various environments.

The Raypak 500 model offers a balance between efficiency and compactness. It features eco-friendly technology that reduces energy consumption without sacrificing performance. The integrated thermostat allows users to maintain consistent water temperatures, making it ideal for residential pools. This model is well-regarded for its user-friendly digital display, simplifying operation and monitoring.

For those needing a more moderate capacity, the Raypak 300 is an efficient choice. It combines robust engineering with an easy-to-use interface. Its advanced ignition system improves reliability while minimizing energy waste. The Raypak 300’s compact design allows for easy installation in various spaces, making it an excellent option for smaller pools.

The Raypak 400 heats water quickly and efficiently, making it suitable for both residential pools and spas. It features a high-capacity heating system that ensures optimal performance. With a clear LED display, users can easily monitor their settings, while the integrated diagnostics provide real-time feedback for maintenance and troubleshooting.

Lastly, the Raypak 700 model is known for its versatility and robust performance. It is equipped with advanced safety features, including a high limit switch and water flow detection mechanism, to ensure safe operation. The model's energy-efficient design enhances its eco-friendliness, making it a popular choice among environmentally conscious users.

Collectively, these Raypak models exemplify superior engineering, performance, and user-friendliness. Their innovative features ensure that they meet the varied demands of pool owners while providing reliable heating solutions for leisure and relaxation. Whether for commercial or residential use, the Raypak 850, 500, 300, 400, and 700 offer unmatched quality and efficiency.