Elbow
Combustion
Air
Intake
Exhaust
Vent
1"
18" Min.
36" Max.
A
A
Exhaust
Plumbing Vent Roof Boot (Typ. Both Pipes)
A= 12" Above Roof or Snow Accumulation Level
Figure 20. Vertical Vent Termination
DRAINAGE OF CONDENSATE FROM FURNACE
The condensate drainage system is internal to the furnace. The drain may exit either the right or left side of the furnace cabinet. For a right side drain simply extend the tubing out of the 7/8" hole in the cabinet, see Figure 21.
For a left side drain follow the steps below:
1.Loosen the clamp on the soft exit tube (see Figure 21.)
2.Rotate the soft exit tube (counter clockwise, 180° upflow G6RC/RD models; clockwise 90° downflow G6RL models.)
3.
4.Route the tubing out of the 7/8" hole located 8 inches up from the bottom furnace.
The condensate should drain from the plastic collector box (location A in Figure 21) as droplets or a small stream. If you notice the furnace has operated for more than 5 minutes without drain- ing or the red status light on the control board is pulsing a
1.Remove the collector box soft tube at loca- tion A in Figure 21 and insure the exit from
G6RC & G6RD | G6RL | A |
A |
|
|
Collector Box |
| Collector Box |
|
|
|
| Left |
|
|
|
|
|
| Side | Rotate clockwise | |
Left Side | Rotate counter |
| Drain | |||
Drain |
|
|
| (Step 2) | ||
clockwise (Step 2) | Route to |
|
| |||
|
|
|
| |||
|
|
| floor drain. |
|
|
|
8" |
|
| ...OR | 8" |
|
|
|
| Route to |
|
| ||
|
|
|
|
|
| |
|
|
| condensate |
|
|
|
"HARD" J |
| Clamp | pump. Keep | "HARD" J | Clamp | |
| (Loosen For Step 1) | downward | (Loosen For Step 1) | |||
Drain Tube |
| Drain Tube | (Retighten for Step 3) | |||
|
| (Retighten for Step 3) slope. |
|
|
Route to floor drain.
...OR Route to condensate pump. Keep downward slope.
Figure 21. Furnace with Condensate Drain Trap Assembly
21