Specifications
Model | RV53i |
| RV53e | ||
Minimum Gas Consumption Btu/h | 15,000 |
| 20,200 (LP) | 19,000 (NG) | |
Maximum Gas Consumption Btu/h | 150,000 |
| 120,000 | ||
|
|
|
|
| |
Hot water capacity (Min - Max) * | 0.6 - 5.3 GPM (2.4 - 20.0 L/min) |
| |||
Hot water capacity (45°F rise) | 5.3 GPM (20.0 L/min) |
| 4.2 GPM | (16.0 L/min) | |
|
|
|
|
|
|
Temperature Settings (without temperature | 120º F (49º C), default or | 140º F (60º C) |
| ||
controller) |
|
| |||
|
|
|
|
| |
Temperature Controller Default Setting | 104º F (40º C) |
| |||
|
|
|
|
|
|
Maximum Temp Setting (residential) | 140º F (60º C) |
| |||
see Temperature Ranges for more information |
| ||||
|
|
|
| ||
Minimum Temperature Setting | 98º F (37º C) |
| |||
|
|
|
|
|
|
Weight |
| 51 lb (23.0 kg) |
| 34.2 lb | (15.5 kg) |
Energy Factor |
| 0.82 |
| 0.82 | |
|
|
|
|
|
|
Noise level |
| 49 dB |
|
| |
| Normal | 55 W |
| 33 W | |
Electrical Consumption |
|
|
|
|
|
Standby | 2 W |
|
| ||
| 184 W |
| 74W | ||
|
|
|
|
|
|
| Fixed |
|
| ||
Minimum Gas Supply | Natural Gas | 5.0 inch W.C. |
| ||
|
|
|
|
| |
Pressure | Propane | 8.0 inch W.C. |
| ||
|
| ||||
Maximum Gas Supply | Natural Gas | 10.5 inch W.C. |
| ||
|
|
|
|
| |
Pressure | Propane | 13.5 inch W.C. |
| ||
|
| ||||
Type of Appliance |
| Temperature controlled continuous flow gas hot water system. | |||
|
|
|
| ||
Operation |
| With or without temperature controller, mounted in kitchen, bathroom, etc. | |||
Approved Gas Type |
| Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location. | |||
|
|
|
| ||
Connections |
| Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT | |||
Ignition System |
| Direct Electronic Ignition |
| ||
|
|
|
| ||
Electric Connections |
| Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital) | |||
Water Temperature Control | Simulation Feedforward and Feedback. |
| |||
|
|
|
| ||
Water Supply Pressure |
| Minimum Water Pressure: 20 PSI (Recommended | |||
|
|
|
|
|
|
Maximum Water Supply Pressure | 150 PSI |
|
| ||
|
|
|
| ||
Remote Control Cable |
| ||||
Energy Star Qualified |
| Yes |
|
| |
|
|
|
|
|
|
Certified for installation in manufactured | Yes |
|
| ||
(mobile) homes |
|
|
| ||
|
|
|
|
| |
|
|
|
|
|
|
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.
RV53i & RV53e Operation and Installation Manual | 3 |