Rinnai RV53E, RV53I Temperature Controller Settings, Model Temperature Settings Available ºF

Page 6

Temperature Controller Settings

This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time. The available temperatures for a given model are provided below.

Model

 

 

 

 

Temperature Settings Available (ºF)

 

 

 

 

RV53i

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

RV53e

 

 

 

 

 

 

 

 

 

 

 

 

 

*

*

Temp in Celsius ºC

37

38

39

40

41

42

43

46

49

52

54

57

60

66

71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*MCC-91 Temperature Controller

These settings require the MCC-91 controller. When the MCC-91 controller is connected, these higher temperatures are available on all controller models in the system.

Use of an MCC-91 controller in a residential dwelling will reduce the warranty coverage to that of a commercial warranty application which is no coverage for these models (except when an MCC-91 is used with a Rinnai Hydronic Air Handler). See the Warranty Information for more information on the warranty.

The MCC-91 controller is intended for commercial and hydronic applications only. If an MCC-91 controller is used in a residential dwelling for a hydronics application, a mixing valve must also be installed to limit the potable hot water temperature to a safe temperature. Water temperatures over 125º F (52º C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be liable for damages resulting from such misuse or misapplication.

Suggested temperatures are

Kitchen

120

ºF (49º C)

Shower

98 - 110 ºF (37 - 43 ºC)

Bath Fill

102

- 110 ºF (39 - 43 ºC)

These temperatures are suggestions only.

A temperature lower than 98 ºF (37 ºC) can be obtained at the tap by mixing with cold water.

To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button for 5 seconds while the water heater is OFF.

Temperature Options Without a Temperature Controller

The default temperature setting for this appliance installed without a temperature controller is 120º F

120º F (49º C)

140º F (60º C)

(49º C). If desired the temperature setting can be changed to 140º F (60º C) by adjustment of a switch.

Set switch 5 to ON to obtain 140º F water temperature setting.

Set switch 5 to OFF (default) to obtain 120º F water temperature setting.

If a temperature controller is installed then switch 5 has no effect on temperature settings.

Switch No.

ON

O1

F

F 2

3

4

5

6

7

8

Switch No.

ON

O1

F

F 2

3

4 5 6 7 8

6

RV53i & RV53e Operation and Installation Manual

Image 6
Contents Result causing property damage, personal injury or death ANS Z21.10.3 CSATable of Contents Specifications ModelSafety Behaviors and Practices Safety Features Consumer Safety InformationSafety Definitions Description of OperationHow to Set the Temperature Operating InstructionsModel Temperature Settings Available ºF Temperature Controller SettingsTemperature Options Without a Temperature Controller MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Filling the Tub Setting Controller to MuteSetting the Clock Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterRV53iRV53e RV53i Electrical ConnectionGas Piping RV53ePipe Sizing Procedure Example Pressure Relief Valve Maintenance Isolation Valves Installation InstructionsPressure Relief Valve Installation Instructions Water PipingPressure Relief Valve Freeze ProtectionWhen the water heater or external piping has frozen Freeze Protection MethodsManual draining of the water heater Freeze Protection Piping KEYError Indication or Air Handler Control Switch RV53i Recommended Piping for Basic InstallationRinnai Water Heater Recommended Piping for Circulation Systems For this applicationIntake / Exhaust Guidelines Installation requirementsVenting Instructions RV53i CondensateMaximum Vent Length Vent ProductsManufacturer Product Parts Flue Installation Concentric Venting RV53i Description Canadian Installations US Installations Flue Terminal Clearances ANS Z21.10.3, CSAAdditional Clearances RV53iNumber Connected Accessories Necessary Water Heaters Connecting Multiple Water HeatersHigh Altitude Installations GuidelinesCanada only Location Temperature Controller InstallationConfigurations Cable Lengths and SizeTemperature Controller Mounting the Controller RV53iMounting the Controller RV53e For Your Safety Read Before Operating Operating InstructionsTechnical Data Pressure Drop CurveOutlet Flow Data Space Heating Temperature SettingReplacement PumpsDimensions RV53eLadder Diagrams What is covered? Warranty InformationLimited Warranty Consumer SupportHow do I get service? What is not covered? What will Rinnai do?Limitation on warranties State Regulations Important In the State of Massachusetts 248 CMR 4.00Instructions d’installation Instructions dutilisationSupport à la clientele Instructions dutilisation Temp. d’eauModel Arrangements de température disponibles ºF Plages de température avec un contrôleur de températureOptions de température sans contrôleur de température Les températures suggérées sont deEntretien Instructions dinstallation Instructions généralesÉcartements par rapport à lappareil Fixation du chauffe-eauInstallation à altitude élevée Tuyauterie de gazInstructions générales Valve de dégagement de pression Instructions d’Installation Tuyauterie deauValve à Bille / Valve de dégagement de pression Qualité de leau Soupape de sûretéNiveau maximum Tuyauterie recommandée pour installation de base LégendeInstructions de ventilation RV53i Consignes pour aspiration/évacuationCondensat Longueur maximum de ventilation Produits de ventilationConstructeur Produit Pièces Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée RV53i Instructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier FUS TherGarantie limitée Support à la clientèleLinformation de garantie Quest-ce qui est couvert ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesU287-1821X0100