Rinnai RV53I, RV53E installation manual Result causing property damage, personal injury or death

Page 1

Tankless Water Heater

Operation and Installation Manual

RV53i .................. REU-VB2020FFU-US

RV53e ................. REU-VAM1620W-US

Certified for installation in manufactured (mobile) homes.

 

 

Table of Contents

2

 

 

Consumer Safety Information

4

 

 

Operating Instructions

5

 

 

Maintenance

9

 

 

Error Codes

10

RV53i

RV53e

 

 

 

 

Installation Instructions

14

 

 

Consumer Support

39

 

 

French Version

42

 

 

Register your product at www.rinnairegistration.com or call

 

 

1-866-RINNAI1 (746-6241)

 

result causing property damage, personal injury or death.

RV53i

only

ANS Z21.10.3

CSA 4.3

Image 1
Contents ANS Z21.10.3 CSA Result causing property damage, personal injury or deathTable of Contents Model SpecificationsSafety Definitions Consumer Safety InformationSafety Behaviors and Practices Safety Features Description of OperationOperating Instructions How to Set the TemperatureTemperature Options Without a Temperature Controller Temperature Controller SettingsModel Temperature Settings Available ºF MCC-91 Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Setting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Code Fault Remedy Error CodesCode Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Circulating Pump Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceRV53iRV53e Gas Piping Electrical ConnectionRV53i RV53ePipe Sizing Procedure Example Pressure Relief Valve Installation Instructions Isolation Valves Installation InstructionsPressure Relief Valve Maintenance Water PipingFreeze Protection Pressure Relief ValveFreeze Protection Methods When the water heater or external piping has frozenManual draining of the water heater KEY Freeze Protection PipingRecommended Piping for Basic Installation Error Indication or Air Handler Control Switch RV53iRinnai Water Heater For this application Recommended Piping for Circulation SystemsVenting Instructions RV53i Installation requirementsIntake / Exhaust Guidelines CondensateVent Products Maximum Vent LengthManufacturer Product Parts Flue Installation Concentric Venting RV53i Flue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US InstallationsRV53i Additional ClearancesHigh Altitude Installations Connecting Multiple Water HeatersNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Configurations Temperature Controller InstallationLocation Cable Lengths and SizeMounting the Controller RV53i Temperature ControllerMounting the Controller RV53e Operating Instructions For Your Safety Read Before OperatingPressure Drop Curve Technical DataOutlet Flow Data Replacement Temperature SettingSpace Heating PumpsRV53e DimensionsLadder Diagrams Limited Warranty Warranty InformationWhat is covered? Consumer SupportWhat will Rinnai do? How do I get service? What is not covered?Limitation on warranties Important In the State of Massachusetts 248 CMR 4.00 State RegulationsInstructions dutilisation Instructions d’installationSupport à la clientele Temp. d’eau Instructions dutilisationOptions de température sans contrôleur de température Plages de température avec un contrôleur de températureModel Arrangements de température disponibles ºF Les températures suggérées sont deEntretien Instructions générales Instructions dinstallationFixation du chauffe-eau Écartements par rapport à lappareilTuyauterie de gaz Installation à altitude élevéeInstructions générales Tuyauterie deau Valve de dégagement de pression Instructions d’InstallationValve à Bille / Valve de dégagement de pression Soupape de sûreté Qualité de leauNiveau maximum Légende Tuyauterie recommandée pour installation de baseConsignes pour aspiration/évacuation Instructions de ventilation RV53iCondensat Produits de ventilation Longueur maximum de ventilationConstructeur Produit Pièces Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée RV53i VanneMa ualmanuelleValve Instructions dutilisationFUS Ther Diagramme en escalierLinformation de garantie Support à la clientèleGarantie limitée Quest-ce qui est couvert ?Limitation sur les garanties Que fait Rinnai pour exercer la garantie ?U287-1821X0100