Rinnai RV53I, RV53E Flushing the Heat Exchanger Error Code LC or, Circulating Pump

Page 13

Flushing the Heat Exchanger (Error Code: LC or 00)

An “LC” or “00” error code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. After flushing, reset the LC fault code by turning off the power to the unit and turning the power back on.

1.Disconnect electrical power to the water heater.

2.Close the shutoff valves on both the hot water and cold water lines (V3 and V4).

3.Connect pump outlet hose (H1) to the cold water line at service valve (V2).

4.Connect drain hose (H3) to service valve (V1).

5.Pour 4 gallons of undiluted virgin, food grade, white vinegar into pail.

6.Place the drain hose (H3) and the hose (H2) to the pump inlet into the cleaning solution.

7.Open both service valves (V1 and V2) on the hot water and cold water lines.

8.Operate the pump and allow the cleaning solution to circulate through the water heater for 1 hour at a rate of 4 gallons per minute (15.1 liters per minute).

9.Turn off the pump.

10.Rinse the cleaning solution from the water heater as follows:

a.Remove the free end of the drain hose (H3) from the pail.

b.Close service valve, (V2), and open shutoff valve, (V4). Do not open shutoff valve, (V3).

c.Allow water to flow through the water heater for 5 minutes

d.Close service valve, (V1), and open shutoff valve, (V3).

11.Disconnect all hoses.

12.With (V4) closed, remove the in-line filter at the cold water inlet and clean out any residue. Place filter back into unit and open (V4).

13.Restore electrical power to the water heater.

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

Rinnai

Water Heater

In-line

Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1

 

 

 

 

 

 

 

 

 

V2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLEAN THERMISTORS

Remove and clean thermistors with a soft cloth or sponge after removing O-rings.

Cleaning solution is 4 gallons of undiluted virgin, food grade, white vinegar.

H3

V3

V4

 

 

 

 

 

Hot

Cold

Gas

 

Supply

 

Water

 

Water

 

 

Line

 

 

Line

 

 

 

 

H2

H1

Circulating Pump

RV53i & RV53e Operation and Installation Manual

13

Image 13
Contents ANS Z21.10.3 CSA Result causing property damage, personal injury or deathTable of Contents Model SpecificationsSafety Definitions Consumer Safety InformationSafety Behaviors and Practices Safety Features Description of OperationOperating Instructions How to Set the TemperatureTemperature Options Without a Temperature Controller Temperature Controller SettingsModel Temperature Settings Available ºF MCC-91 Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Setting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Code Fault Remedy Error CodesCode Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Circulating Pump Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceRV53iRV53e Gas Piping Electrical ConnectionRV53i RV53ePipe Sizing Procedure Example Pressure Relief Valve Installation Instructions Isolation Valves Installation InstructionsPressure Relief Valve Maintenance Water PipingFreeze Protection Pressure Relief ValveFreeze Protection Methods When the water heater or external piping has frozenManual draining of the water heater KEY Freeze Protection PipingRecommended Piping for Basic Installation Error Indication or Air Handler Control Switch RV53iRinnai Water Heater For this application Recommended Piping for Circulation SystemsVenting Instructions RV53i Installation requirementsIntake / Exhaust Guidelines CondensateVent Products Maximum Vent LengthManufacturer Product Parts Flue Installation Concentric Venting RV53i Flue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US InstallationsRV53i Additional ClearancesHigh Altitude Installations Connecting Multiple Water HeatersNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Configurations Temperature Controller InstallationLocation Cable Lengths and SizeMounting the Controller RV53i Temperature ControllerMounting the Controller RV53e Operating Instructions For Your Safety Read Before OperatingPressure Drop Curve Technical DataOutlet Flow Data Replacement Temperature SettingSpace Heating PumpsRV53e DimensionsLadder Diagrams Limited Warranty Warranty InformationWhat is covered? Consumer SupportWhat will Rinnai do? How do I get service? What is not covered?Limitation on warranties Important In the State of Massachusetts 248 CMR 4.00 State RegulationsInstructions dutilisation Instructions d’installationSupport à la clientele Temp. d’eau Instructions dutilisationOptions de température sans contrôleur de température Plages de température avec un contrôleur de températureModel Arrangements de température disponibles ºF Les températures suggérées sont deEntretien Instructions générales Instructions dinstallationFixation du chauffe-eau Écartements par rapport à lappareilTuyauterie de gaz Installation à altitude élevéeInstructions générales Tuyauterie deau Valve de dégagement de pression Instructions d’InstallationValve à Bille / Valve de dégagement de pression Soupape de sûreté Qualité de leauNiveau maximum Légende Tuyauterie recommandée pour installation de baseConsignes pour aspiration/évacuation Instructions de ventilation RV53iCondensat Produits de ventilation Longueur maximum de ventilationConstructeur Produit Pièces Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée RV53i VanneMa ualmanuelleValve Instructions dutilisationFUS Ther Diagramme en escalierLinformation de garantie Support à la clientèleGarantie limitée Quest-ce qui est couvert ?Limitation sur les garanties Que fait Rinnai pour exercer la garantie ?U287-1821X0100