Error Code Table
Code | Fault |
| Remedy |
|
|
|
|
|
|
14 | Thermal Fuse |
| Check gas type of unit and ensure it matches gas type being used. |
|
|
|
| Check for restrictions in air flow around unit and vent terminal. |
|
|
|
| Check for low water flow in a circulating system causing |
|
|
|
| Ensure dip switches are set to the proper position. |
|
|
|
| Check for foreign materials in combustion chamber and/or exhaust piping. |
|
|
|
| Check heat exchanger for cracks and/or separations. |
|
|
|
| Check heat exchanger surface for hot spots which indicate blockage due to scale |
|
|
|
| Refer to instructions in manual for flushing heat exchanger. |
|
|
|
| Measure resistance of safety circuit. |
|
|
|
| Ensure high fire and low fire manifold pressure is correct. |
|
|
|
| Check for improper conversion of product. |
|
16 | Over Temperature |
| Check for restrictions in air flow around unit and vent terminal. |
|
| Warning |
| Check for low water flow in a circulating system causing |
|
|
|
| Check for foreign materials in combustion chamber and/or exhaust piping. |
|
|
|
| Check for clogged heat exchanger. |
|
31 | Burner Sensor Error |
| Measure resistance of sensor. |
|
|
|
| Replace sensor. |
|
32 | Outgoing Water |
| Check sensor wiring for damage. |
|
| Temperature Sensor |
| Measure resistance of sensor. |
|
| Fault |
| Clean sensor of scale |
|
|
|
| Replace sensor. |
|
33 | Heat Exchanger |
| Check sensor wiring for damage. |
|
| Outgoing Temperature |
| Measure resistance of sensor. |
|
| Sensor Fault |
| Clean sensor of scale |
|
|
|
| Replace sensor. |
|
34 | Combustion Air |
| Check for restrictions in air flow around unit and vent terminal. |
|
| Temperature Sensor |
| Check sensor wiring for damage. |
|
| Fault |
| Measure resistance of sensor. |
|
|
|
| Clean sensor of scale |
|
|
|
| Ensure fan blade is tight on motor shaft and is in good condition. |
|
|
|
| Replace sensor. |
|
52 | Modulating Solenoid |
| Check modulating gas solenoid valve wiring harness for loose or damaged terminals. |
|
| Valve Signal Abnormal |
| Measure resistance of valve coil. |
|
61 | Combustion Fan Failure |
| Ensure fan will turn freely. |
|
|
|
| Check wiring harness to motor for damaged and/or loose connections. |
|
|
|
| Measure resistance of motor winding. |
|
65 | Water Flow Control Fault |
| The water flow control valve has failed to close during the bath fill function. Immediately turn | |
|
|
| off the water and discontinue the bath fill function. Contact a state qualified or licensed |
|
|
|
| contractor to service the appliance. |
|
71 | Solenoid Valve Circuit |
| Replace the PC Board. |
|
| Fault |
|
|
|
72 | Flame Sensing Device |
| Ensure flame rod is touching flame when unit fires. |
|
| Fault |
| Check all wiring to flame rod for damage. |
|
|
|
| Remove flame rod and check for carbon |
|
|
|
| Check inside burner chamber for any foreign material blocking flame at flame rod. |
|
|
|
| Measure micro amp output of sensor circuit with flame present. |
|
|
|
| Replace flame rod. |
|
73 | Burner Sensor Circuit |
| Check sensor wiring and PC board for damage. |
|
| Error |
| Replace sensor. |
|
LC | Scale |
| Flush heat exchanger. Refer to instructions in manual. |
|
| Exchanger (when |
| Replace heat exchanger. |
|
| checking maintenance |
| NOTE: The LC code is the only error code that will allow the unit to keep running. The |
|
| code history, “00” is |
| display will alternate between the LC code and the temperature setting. The controller will |
|
| substituted for “LC”) |
| continue to beep. The LC code will reset if power is turned off and then on. |
|
No | Nothing happens when |
| Clean inlet water supply filter. |
|
code | water flow is activated. |
| On new installations ensure hot and cold water lines are not reversed. |
|
|
|
| Check for bleed over. Isolate unit from building by turning off cold water line to building. |
|
|
|
| Isolate the circulating system if present. Open your pressure relief valve; if water is |
|
|
|
| flowing, there is bleed over in your plumbing. |
|
|
|
| Ensure you have at least the minimum flow rate required to fire unit. |
|
|
|
| Ensure turbine spins freely. |
|
|
|
| Measure the resistance of the water flow control sensor. |
|
|
|
| Check for DC shorts at components. |
|
|