Trouble Indications

The OmniLT constantly monitors the alarm zones and several internal matters and will alert you if it detects trouble. The particular trouble is indicated on the bottom line of the display and a trouble signal is given by beeping the console beeper continuously, 2 beeps per second.

When any trouble condition occurs, the console will beep twice per second and continue to beep until the ' * ' key (cancel) is pressed to acknowledge the trouble. The console will say "TRBL NOW" (trouble now) if the trouble condition actually exists while you are looking at the console. It will say "HAD TRBL" (had trouble) if the trouble occurred and then corrected itself.

The following are trouble indications and their meanings:

¾ZONE NAME TRBL NOW or HAD TRBL: If the reading for a zone becomes abnormal, trouble will be indicated on that zone -SeeStatus \ Test. Excessive resistance in the contact and wiring usually causes trouble on security zones. If the cause is not obvious, call your installer for service.

¾AC POWER OFF TRBL NOW or HAD TRBL: Indicated if the normal house current powering the OmniLT controller is interrupted for more than 3 minutes. If this happens without good cause, check the wall mounted transformer to ensure that it hasn't come out of the wall socket; check to see that the socket has power; check the MAIN fuse (F3) on the OmniLT controller to be sure that it is good.

¾BATTERY LOW TRBL NOW or HAD TRBL: Every hour, the OmniLT takes a dynamic test of the battery. If the battery voltage is too low, then the console will indicate "BATTERY LOW". If this happens, make sure that the battery is connected. The "BATTERY LOW" indication will remain until the next battery test is executed, 1 hour later, or when a Status Test command is given.

¾COMMUNICATOR TRBL NOW or HAD TRBL: Indicated if the digital communicator (not the voice dialer) was unable to make contact with the Central Station after trying both numbers multiple times. If this happens, there could be a problem with the system, central station, or the phone line. Call your installer for service.

¾FUSE TRBL NOW or HAD TRBL: Indicated when the solid state fuse that protects the "Auxiliary" power supply opens. The fuse will automatically reset when the fault condition is cleared.

¾PHONE LINE DEAD TRBL NOW or HAD TRBL: Indicated if the phone line is dead for more than 1 minute.

To silence the trouble beeps on the console, press the ' * ' key. If more than one type of trouble has occurred, the display will show each one for two seconds. Pressing the ' * ' key will acknowledge all trouble indications.

If the trouble condition occurs again, the console beeper will beep again - See Set Up Arming, Beep On Trouble if you wish to disable the beeper.

¾NO CONTROLLER DATA: Indicated in the event that the console's alarm functions are no longer operational. This may indicate a wiring problem to the console or a more serious problem. Call your installer for service.

Codes

There are 8 user codes that you may assign to users of the system. All OmniLT codes are 4 digits in length. A code can be any number from 0001 to 9999. Each user should be assigned a security code with an authority level and times in which the code will be valid. Memorize your codes! Don't give them to anyone who doesn't need to know them.

The levels of authority that you can assign to a user code are Master, Manager, and User.

Master Code

The Master code allows complete access to the entire system. Only the owner(s) or the one(s) who will govern the system should have and use the master code.

User code 1 is always set to a Master code - See Set Up Codes.

12

Image 16
Contents Document Number 21R00-1Rev. January Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights ReservedOVERALL DESCRIPTION SECURITY SYSTEM OPERATIONCONTROL ContentsSETUP TELEPHONE CONTROLINTRODUCTION Underwriters Laboratories UL ListingOVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniLT Maintenance CancelConfirmation Beep Time OutSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated Fire Alarm Activated Gas Alarm ActivatedEmergency Keys OMNIDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyCodes Trouble IndicationsMaster Code Panic Switches Testing Your SystemManager Code User CodeCONTROL About UPBWhen set to UPB, the OmniLT controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsWhen set to CentraLite, the OmniLT controller can About Lutron RadioRAAbout House Controllers About CentraLiteWhen set to RadioRA, the OmniLT controller can About ALCAbout House CodeConfiguring Lighting Scenes in an HLC Room Scrolling Through NamesControlling Units Controlling a Room of HLC LightingOperation StepControlling CentraLite Units Controlling RadioRA Units Controlling ALC or X-10UnitsTimed Commands Ramp Command ALCScene Command Compose Controlling Compose UnitsInternal Flags Status of a UnitControlling Outputs All Lights On All On / OffAll Off Scene Commands Scene Set CommandScene On Command Leviton Scene ControlScene Off Command Setting a Link Lighting ScenesUPB Links Activating and Deactivating LinksButtons Executing Phantom ButtonsExecuting CentraLite Scenes Leave for Work ButtonHAI RC-SeriesThermostats Temperature ControlDinner for Two Button For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors Freeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature Upstairs 2=LOW 3=HIGH #=STATTemperature Alarms HumidityStatus Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINEEvent Log Show EventsShow Message MessagesLog Message Clear Message Say MessagePhone Message Send Message Pro-LinkPro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated TELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesAlternate Method Phone Access Denied - Remote LockoutMain Menu PC Access When a Two-WayAudio Module is being usedPanic Button over the Phone # # # # # # Recording Your AddressEmergency Dial-Out Digital DialerVoice Dialer How the OmniLT Voice Dialer WorksWhat You Hear - If Your OmniLT Calls You Entering the CodeSETUP Set Up Codes1 = Master 2 = ManagerSet Up Time Set Up ProgramsTIME Duress Code1 = Add Programs 2 = Show Programs3 = Delete All Programs Edit Programs When Edit ProgramsTimes Programs Control Unit / Switch Press Event Buttons Button and Event ProgramsCorresponding Switch Table SwitchOmniLT UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsUPB Link Triggers Alarm Event ButtonsX-10Event Buttons Miscellaneous Event Buttons Message Event Buttons Pro-LinkSwitch Press Event Buttons CentraLite Edit Program CommandProgram Control Commands Unit Toggle Command Program Security CommandsProgram Button Commands WHEN LINK 1 ON Porch Light STATUSProgram All On / All Off Commands Program Video CommandsProgram Message Commands Edit Program ConditionProgram Security Mode Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsTelephone Access Set Up DialAnswer Outside Call Remote Commands Rings Before AnswerDial Type My Phone NumberSet Up Arming Dial Out NumbersDial Order Entry DelayEnable Quick Arm Enable Auto BypassAll On For Alarm Exit DelaySet up Miscellaneous Announce AlarmsEnable Freeze Alarm Flash For AlarmFORMAT NUMBERDESCRIPTION House Code All OffLatitude, Longitude, and Time Zone ZONE NAMESet Up Names Daylight SavingsNUMBER DESCRIPTIONSet Up Voice Set Up Address UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGFEDERAL COMMUNICATION COMMISSION NOTICE HAI 21487 Bayou Ct Abita Springs, LACANADIAN INDUSTRY CANADA NOTICE APPENDIX A - SPECIFICATIONS CONTROLLER OUTPUTSUL RATINGS MAXIMUMAPPENDIX B - CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTIONS CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage NOTE TO INSTALLER HAI New Orleans, LA U S A