Home Automation SECURITY SYSTEM owner manual About ALC, House Code, Unit Numbers, ALC Module Types

Page 21
When set to RadioRA, the OmniLT controller can:

When set to RadioRA, the OmniLT controller can:

¾Send commands (on, off, and level) to individual Switches and Dimmers

¾Receive status (on and off) from individual Switches and Dimmers

¾Receive commands when buttons are pressed on Master Controls

¾Execute Phantom Button commands

About ALC

ALC is intended for installation in homes, which have been pre-wired for installation of ALC system products. OmniLT controls lights and appliances by sending commands over the ALC signal wiring to ALC Switch Modules. ALC Switches communicate with the OmniLT over low voltage signal wire. They are two-way devices, so the controller always knows the actual status of the switch. In addition, ALC switches can be used to set scenes by triggering macros in OmniLT.

When ALC Lighting Control Modules are being used, it is also possible to "ramp" the lighting level of an ALC Dimmer Switch to a new level at a controllable ramp rate.

ALC Module Types

The ALC modules types are: Dimmer Switch, Relay Switch, Slave Switch, Program Switch, and 4-Button Scene Switch Modules.

About X-10

The OmniLT controls lights and appliances by sending commands over your existing electrical wiring to special switches, outlets, receptacles, and modules, collectively referred to as X-10. Each module (or group of modules) is assigned a House Code and a Unit Number so that the OmniLT can control the modules individually. When a module hears a command from the OmniLT for its house code and unit number, it executes the command.

There are 3 different X-10 formats: Standard X-10 (Preset Dim), Extended X-10 (Extended Level), and Compose.

Any module that is "X-10 Compatible" will work with the OmniLT. The modules come in various types.

House Code

OmniLT can control up to 16 lighting and appliance devices. Each device (switches, modules, and keypad) has its own Unit Number (1-16). The “House Code” is used to configure the lighting protocol format such as: Standard X-10, Extended X-10, Lightolier Compose, UPB (open UPB format where you can use the programming capability in the OmniLT controller to communicate with the UPB network), Lutron RadioRA, CentraLite, or HAI Lighting Control (HLC). Only one House Code can be configured on OmniLT.

Unit Numbers

OmniLT systems have 36 total Unit Numbers. They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, or X-10 module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows:

OmniLT Unit Numbers

1 - 16

17 - 24

25

26

27 - 28

29 – 36

Module / Output Unit Numbers

HLC Room 1 and 2, UPB Unit ID 1-16, ALC addresses 1-16, CentraLite loads 1-16, RadioRA Lighting Zones and Master Controls 1-16, or X-10 modules 1 – 16 (House Code X)

Voltage Outputs (1-16), Fully Configurable on Model 22A00-1 OmniLT Expansion Module* Thermostat Output (Fully Configurable)

Bell Output

Hardwire Outputs 1 and 2 (Fully Configurable) Internal Flags

“X” Represents the House Code setting on the OmniLT Controller “*” If used

17

Image 21
Contents Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights Reserved Document Number 21R00-1Rev. JanuarySECURITY SYSTEM OPERATION OVERALL DESCRIPTIONCONTROL ContentsTELEPHONE CONTROL SETUPUnderwriters Laboratories UL Listing INTRODUCTIONConsole Operation OVERALL DESCRIPTION1- OFF 2- DAYDisplay Menus Normal Top-LevelDisplay6- UP ARROW 7- CONSOLE LEDMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel OmniLT MaintenanceConfirmation Beep Time OutArming the Security System SECURITY SYSTEM OPERATION0 = OFF 1 = DAY2 = NIGHT Using Shortcut Keys3 = AWAY 4 = VACATIONQuick Arm 9 = RESTOREBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated Gas Alarm Activated Fire Alarm ActivatedEmergency Keys OMNIAlarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code Testing Your System Panic SwitchesManager Code User CodeAbout UPB CONTROLRoom Controller LED Indicators When set to UPB, the OmniLT controller canHAI Lighting Control HLC Format About RoomsAbout Lutron RadioRA When set to CentraLite, the OmniLT controller canAbout House Controllers About CentraLiteAbout ALC When set to RadioRA, the OmniLT controller canAbout House CodeScrolling Through Names Configuring Lighting Scenes in an HLC RoomControlling Units Controlling a Room of HLC LightingStep OperationControlling CentraLite Units Controlling ALC or X-10Units Controlling RadioRA UnitsRamp Command ALC Timed CommandsScene Command Compose Controlling Compose UnitsStatus of a Unit Internal FlagsControlling Outputs All On / Off All Lights OnAll Off Scene Set Command Scene CommandsScene On Command Leviton Scene ControlSetting a Link Lighting Scenes Scene Off CommandUPB Links Activating and Deactivating LinksExecuting Phantom Buttons ButtonsExecuting CentraLite Scenes Leave for Work ButtonTemperature Control HAI RC-SeriesThermostatsDinner for Two Button For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors IMPORTANT NOTES Freeze AlarmsIndoor and Outdoor Temperature Upstairs 2=LOW 3=HIGH #=STATHumidity Temperature AlarmsStatus Temperature Control of AppliancesConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStep Operation Setup Mode for HLC DevicesStep Operation Step OperationOFFHK - OFF HOOK ONHK - ON HOOKRING - RINGING DEAD - DEAD PHONE LINEShow Events Event LogMessages Show MessageLog Message Say Message Clear MessagePhone Message Send Message Pro-LinkPro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated Telephone Interface TELEPHONE CONTROLIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu When a Two-WayAudio Module is being used PC AccessPanic Button over the Phone # # # # # # Recording Your AddressDigital Dialer Emergency Dial-OutVoice Dialer How the OmniLT Voice Dialer WorksEntering the Code What You Hear - If Your OmniLT Calls YouSet Up Codes SETUP1 = Master 2 = ManagerSet Up Programs Set Up TimeTIME Duress Code2 = Show Programs 1 = Add Programs3 = Delete All Programs Edit Programs Edit Programs WhenTimes Programs Button and Event Programs Control Unit / Switch Press Event ButtonsSwitch Corresponding Switch TableOmniLT UPB 6-ButtonKeypadAll On/Off Event Buttons Zone Event ButtonsAlarm Event Buttons UPB Link TriggersX-10Event Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsEdit Program Command Switch Press Event Buttons CentraLiteProgram Control Commands Program Security Commands Unit Toggle CommandProgram Button Commands WHEN LINK 1 ON Porch Light STATUSProgram Video Commands Program All On / All Off CommandsProgram Message Commands Edit Program ConditionProgram Zone Conditions Program Security Mode ConditionsProgram Time Clock Conditions Program Other ConditionsSet Up Dial Telephone AccessAnswer Outside Call Rings Before Answer Remote CommandsDial Type My Phone NumberDial Out Numbers Set Up ArmingDial Order Entry DelayEnable Auto Bypass Enable Quick ArmAll On For Alarm Exit DelayAnnounce Alarms Set up MiscellaneousEnable Freeze Alarm Flash For AlarmNUMBER FORMATDESCRIPTION House Code All OffZONE NAME Latitude, Longitude, and Time ZoneDaylight Savings Set Up NamesNUMBER DESCRIPTIONSet Up Voice Set Up Address FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSHAI 21487 Bayou Ct Abita Springs, LA FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE CONTROLLER OUTPUTS APPENDIX A - SPECIFICATIONSUL RATINGS MAXIMUMCODE CHAR APPENDIX B - CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTIONSDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER