Step

Each lighting scene can also be set or easily changed using the pushbuttons on the HAI UPB™ 6-Button Room Controller, as follows:

Step

Operation

1Press the desired pushbutton on the HAI UPB™ 6-Button Room Controller to activate the current scene (preset lighting level) in each of the HLC devices.

2Use the local Decora-style rocker switch on each UPB™ Wall Switch Dimmer(s) to set the desired lighting level(s) or issue commands from the OmniLT controller.

3Press the pushbutton on the HAI UPB™ 6-Button Room Controller five (5) times quickly.

4Each UPB™ Wall Switch Dimmer will flash its lighting load one time to indicate that the new level has been configured.

Controlling Individual Lighting Loads in an HLC Room or UPB Units

To control individual lighting loads in a room, use the down arrow key to scroll through the list of units. When the unit is displayed, press the ' # ' key. For HLC/UPB lighting loads, the console will display:

LR Sconce

0=OFF 1=ON 2=DIM 3=BRT

LR Sconce

4=LVL 6=LED 9=TIM #=STA

¾Press 0 (OFF) to turn the selected lighting load off .

¾Press 1 (ON) to turn the selected lighting load on.

¾Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level).

¾Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level).

¾Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).

¾Press 6 (LED) to turn on or off the LED behind the specified button on a general purpose 8-Button or 6-Button Keypad.

Specify 1-8 to control the LED behind buttons 1-8 respectively, and then select 0 (OFF) or 1 (ON).

¾Press 9 (TIM) to time the selected unit (On, Off, Dim, Brighten).

Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours.

¾Press # (STA) to see the exact status of a UPB device. When the ' # ' key is pressed, OmniLT sends a “Status Request” message to the selected device for its current state. The exact state is then displayed.

LR Sconce

STATUS 67%

Note: When a UPB signal is received over the powerline, OmniLT will automatically update the status of the device.

Controlling CentraLite Units

Entry Lights

0=OFF 1=ON 2=DIM 3=BRT

Entry Lights

4=LVL 5=RMP 9=TIM #=STA

¾Press 0 (OFF) to turn the selected unit off.

¾Press 1 (ON) to turn the selected unit on.

¾2 (DIM) does not affect CentraLite units.

¾3 (BRT) does not affect CentraLite units.

¾Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).

19

Image 23
Contents Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights Reserved Document Number 21R00-1Rev. JanuaryContents OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION CONTROLTELEPHONE CONTROL SETUPUnderwriters Laboratories UL Listing INTRODUCTION2- DAY OVERALL DESCRIPTIONConsole Operation 1- OFF7- CONSOLE LED Normal Top-LevelDisplayDisplay Menus 6- UP ARROWTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsTime Out OmniLT MaintenanceCancel Confirmation Beep1 = DAY SECURITY SYSTEM OPERATIONArming the Security System 0 = OFF4 = VACATION Using Shortcut Keys2 = NIGHT 3 = AWAYRestoring Zones 9 = RESTOREQuick Arm Bypassing ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated OMNI Fire Alarm ActivatedGas Alarm Activated Emergency KeysPolice Emergency Duress Code Entered or Duress Alarm ActivatedAlarm Reset Alarm CancelMaster Code Trouble IndicationsCodes User Code Panic SwitchesTesting Your System Manager CodeAbout UPB CONTROLAbout Rooms When set to UPB, the OmniLT controller canRoom Controller LED Indicators HAI Lighting Control HLC FormatAbout CentraLite When set to CentraLite, the OmniLT controller canAbout Lutron RadioRA About House ControllersHouse Code When set to RadioRA, the OmniLT controller canAbout ALC AboutControlling a Room of HLC Lighting Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling UnitsControlling CentraLite Units StepOperation Controlling ALC or X-10Units Controlling RadioRA UnitsControlling Compose Units Timed CommandsRamp Command ALC Scene Command ComposeControlling Outputs Status of a UnitInternal Flags All Off All On / OffAll Lights On Leviton Scene Control Scene CommandsScene Set Command Scene On CommandActivating and Deactivating Links Scene Off CommandSetting a Link Lighting Scenes UPB LinksLeave for Work Button ButtonsExecuting Phantom Buttons Executing CentraLite ScenesDinner for Two Button Temperature ControlHAI RC-SeriesThermostats For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors Upstairs 2=LOW 3=HIGH #=STAT Freeze AlarmsIMPORTANT NOTES Indoor and Outdoor TemperatureTemperature Control of Appliances Temperature AlarmsHumidity StatusConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStep Operation Setup Mode for HLC DevicesStep Operation Step OperationDEAD - DEAD PHONE LINE ONHK - ON HOOKOFFHK - OFF HOOK RING - RINGINGShow Events Event LogLog Message MessagesShow Message Send Message Pro-Link Clear MessageSay Message Phone MessagePro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated Remote Phones TELEPHONE CONTROLTelephone Interface In-HousePhonesMain Menu Phone Access Denied - Remote LockoutAlternate Method Recording Your Address PC AccessWhen a Two-WayAudio Module is being used Panic Button over the Phone # # # # # #How the OmniLT Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerEntering the Code What You Hear - If Your OmniLT Calls You2 = Manager SETUPSet Up Codes 1 = MasterDuress Code Set Up TimeSet Up Programs TIME2 = Show Programs 1 = Add Programs3 = Delete All Programs Times Programs Edit ProgramsEdit Programs When Button and Event Programs Control Unit / Switch Press Event ButtonsUPB 6-ButtonKeypad Corresponding Switch TableSwitch OmniLTAll On/Off Event Buttons Zone Event ButtonsX-10Event Buttons Alarm Event ButtonsUPB Link Triggers Message Event Buttons Pro-Link Miscellaneous Event ButtonsProgram Control Commands Edit Program CommandSwitch Press Event Buttons CentraLite WHEN LINK 1 ON Porch Light STATUS Unit Toggle CommandProgram Security Commands Program Button CommandsEdit Program Condition Program All On / All Off CommandsProgram Video Commands Program Message CommandsProgram Other Conditions Program Security Mode ConditionsProgram Zone Conditions Program Time Clock ConditionsAnswer Outside Call Set Up DialTelephone Access My Phone Number Remote CommandsRings Before Answer Dial TypeEntry Delay Set Up ArmingDial Out Numbers Dial OrderExit Delay Enable Quick ArmEnable Auto Bypass All On For AlarmFlash For Alarm Set up MiscellaneousAnnounce Alarms Enable Freeze AlarmHouse Code All Off FORMATNUMBER DESCRIPTIONZONE NAME Latitude, Longitude, and Time ZoneDESCRIPTION Set Up NamesDaylight Savings NUMBERSet Up Voice Set Up Address FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSHAI 21487 Bayou Ct Abita Springs, LA FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE MAXIMUM APPENDIX A - SPECIFICATIONSCONTROLLER OUTPUTS UL RATINGSCODE CHAR APPENDIX B - CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTIONSCODE DESCRIPTIONDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTION CODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER