Home Automation SECURITY SYSTEM What To Do When You Come Home, Burglar Alarm Activated

Page 13

What To Do When You Come Home

Entry through a door:

If you enter your home while the system is armed in the Day or Away modes, using your normal entry door:

Console beeper comes on - display indicates: " *** DISARM SYSTEM *** - PRESS OFF THEN CODE"

Any lights or control modules programmed to come on for the door that you used will do so.

The system will wait the Entry Delay time.

You should go to your console (or telephone) immediately and turn the security system off. If you wish, you may go directly to a different security mode, rather than turning the system Off.

If you return home and hear the alarm sounding or the outdoor lights are flashing, DO NOT ENTER. Use a neighbor's phone to call for help.

What Happens When the Alarm is Activated

Burglar Alarm Activated

If someone enters through any zone other than an Entry-Exit zone, if the security system is in the Night mode, or if the security system is not turned off during the Entry Delay:

The sounder is activated, which makes a loud, continuous sound.

The display shows the type of alarm and the zones that have been tripped:

"BURGLAR ALARM! - ZONE NAME TRIPPED".

If more than one zone is tripped, then the bottom line will show each zone tripped for two seconds.

The When Alarm macro is activated. Any units programmed to come on will do so.

The Flash For Alarm Unit Number begins to flash on and off.

The system now waits the Dial Out Delay. (0 - 60 seconds)

If programmed, the in-house phones are seized (disconnected) and the OmniLT begins to dial out.

If you are having your system monitored by a central station, the central station will be sent a code representing the type of alarm (burglary) and zone involved. In most cases, the central station will call back, requesting your password or passcode.

If you are not using central station monitoring but are using the voice dial out capability, the system looks at the Dial Order to determine which number to call first, and calls that number.

If you are using both central station monitoring and voice dial out, then the voice dial out is delayed by five minutes to give the central station time to call you back.

For more information on the digital and voice dialer - See Digital Dialer and Voice Dialer.

The system continues to sound all alarms and flash the flashing light for 1-30 minutes after the alarm is activated.

After a 1-30 minute period, the sounder is turned off, and the alarm system resets itself. The console beeper stays on. If a zone is tripped after a reset, the sounder will again be activated, and the dialer will again dial out.

At any time, the alarm system can be turned off at the console.

9

Image 13
Contents Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights Reserved Document Number 21R00-1Rev. JanuarySECURITY SYSTEM OPERATION OVERALL DESCRIPTIONCONTROL ContentsTELEPHONE CONTROL SETUPUnderwriters Laboratories UL Listing INTRODUCTIONConsole Operation OVERALL DESCRIPTION1- OFF 2- DAYDisplay Menus Normal Top-LevelDisplay6- UP ARROW 7- CONSOLE LEDMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel OmniLT MaintenanceConfirmation Beep Time OutArming the Security System SECURITY SYSTEM OPERATION0 = OFF 1 = DAY2 = NIGHT Using Shortcut Keys3 = AWAY 4 = VACATIONQuick Arm 9 = RESTOREBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated Gas Alarm Activated Fire Alarm ActivatedEmergency Keys OMNIAlarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Police EmergencyCodes Trouble IndicationsMaster Code Testing Your System Panic SwitchesManager Code User CodeAbout UPB CONTROLRoom Controller LED Indicators When set to UPB, the OmniLT controller canHAI Lighting Control HLC Format About RoomsAbout Lutron RadioRA When set to CentraLite, the OmniLT controller canAbout House Controllers About CentraLiteAbout ALC When set to RadioRA, the OmniLT controller canAbout House CodeScrolling Through Names Configuring Lighting Scenes in an HLC RoomControlling Units Controlling a Room of HLC LightingOperation StepControlling CentraLite Units Controlling ALC or X-10Units Controlling RadioRA UnitsRamp Command ALC Timed CommandsScene Command Compose Controlling Compose UnitsInternal Flags Status of a UnitControlling Outputs All Lights On All On / OffAll Off Scene Set Command Scene CommandsScene On Command Leviton Scene ControlSetting a Link Lighting Scenes Scene Off CommandUPB Links Activating and Deactivating LinksExecuting Phantom Buttons ButtonsExecuting CentraLite Scenes Leave for Work ButtonHAI RC-SeriesThermostats Temperature ControlDinner for Two Button For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors IMPORTANT NOTES Freeze AlarmsIndoor and Outdoor Temperature Upstairs 2=LOW 3=HIGH #=STATHumidity Temperature AlarmsStatus Temperature Control of AppliancesConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStep Operation Setup Mode for HLC DevicesStep Operation Step OperationOFFHK - OFF HOOK ONHK - ON HOOKRING - RINGING DEAD - DEAD PHONE LINEShow Events Event LogShow Message MessagesLog Message Say Message Clear MessagePhone Message Send Message Pro-LinkPro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated Telephone Interface TELEPHONE CONTROLIn-HousePhones Remote PhonesAlternate Method Phone Access Denied - Remote LockoutMain Menu When a Two-WayAudio Module is being used PC AccessPanic Button over the Phone # # # # # # Recording Your AddressDigital Dialer Emergency Dial-OutVoice Dialer How the OmniLT Voice Dialer WorksEntering the Code What You Hear - If Your OmniLT Calls YouSet Up Codes SETUP1 = Master 2 = ManagerSet Up Programs Set Up TimeTIME Duress Code2 = Show Programs 1 = Add Programs3 = Delete All Programs Edit Programs When Edit ProgramsTimes Programs Button and Event Programs Control Unit / Switch Press Event ButtonsSwitch Corresponding Switch TableOmniLT UPB 6-ButtonKeypadAll On/Off Event Buttons Zone Event ButtonsUPB Link Triggers Alarm Event ButtonsX-10Event Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsSwitch Press Event Buttons CentraLite Edit Program CommandProgram Control Commands Program Security Commands Unit Toggle CommandProgram Button Commands WHEN LINK 1 ON Porch Light STATUSProgram Video Commands Program All On / All Off CommandsProgram Message Commands Edit Program ConditionProgram Zone Conditions Program Security Mode ConditionsProgram Time Clock Conditions Program Other ConditionsTelephone Access Set Up DialAnswer Outside Call Rings Before Answer Remote CommandsDial Type My Phone NumberDial Out Numbers Set Up ArmingDial Order Entry DelayEnable Auto Bypass Enable Quick ArmAll On For Alarm Exit DelayAnnounce Alarms Set up MiscellaneousEnable Freeze Alarm Flash For AlarmNUMBER FORMATDESCRIPTION House Code All OffZONE NAME Latitude, Longitude, and Time ZoneDaylight Savings Set Up NamesNUMBER DESCRIPTIONSet Up Voice Set Up Address FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSHAI 21487 Bayou Ct Abita Springs, LA FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE CONTROLLER OUTPUTS APPENDIX A - SPECIFICATIONSUL RATINGS MAXIMUMCODE CHAR APPENDIX B - CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTIONSDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER