Carrier Access 770-0125-AB Alarm SUM Red LED Status, ETH Yellow LED Status Top #1 Bottom

Models: 770-0125-AB

1 96
Download 96 pages 9.24 Kb
Page 31
Image 31

 

 

Installation

 

 

Installing the NSP101 Control Card

 

 

 

Alarm present:

 

 

 

 

 

ALARM SUM Red LED

Status

 

 

 

 

Off

No alarm is present

 

 

 

 

On

Indicates there is at least one critical, major or minor

 

 

active alarm in the chassis

 

 

 

Power input status:

PWR Red LED #2

PWR Red LED #1

Status

(Top)

(Bottom)

 

 

 

 

Off

Off

Both power feeds present; operating normally

 

 

 

Off

On

Power FEED A is not operating

 

 

 

On

Off

Power FEED B is not operating

 

 

 

By default, BROADway is software configured to expect redundant power (using FEED A and FEED B). If you do not wire one of these inputs, the PWR LEDs will lamp as if there was an alarm condition. For more information about how to wire FEED A and FEED B, see Cabling Power and Ground on page 2-6.

If you are only using FEED A (not FEED B), you can configure the BROADway software to disable power input redundancy and disable the appropriate red LED. For information about how to configure your system to disable power input redundancy, refer to the online help.

Ethernet port activity:

ETH Green LED #2

ETH Yellow LED

Status

(Top)

#1 (Bottom)

 

 

 

 

Off

Off

ETH-1 or ETH-2 not connected (link down)

 

 

 

Off

On

ETH-1 or ETH-2 connected (link up)

 

 

 

Flashing

On

Network activity on ETH-1 or ETH-2

 

 

 

BROADway - Release 4.00

2-15

Page 31
Image 31
Carrier Access 770-0125-AB installation manual Alarm SUM Red LED Status, PWR Red LED #2 PWR Red LED #1 Status Top Bottom