Installation

Installing the NHP160 Line Interface Card

4. Connect the other end of the cables to your terminating equipment.

For cable pinouts of the NHP160 SCSI port connector, see NHP160 Connector Pinouts on page A-8.

NHP160 LED Indicators

Each NHP160 line card in a UIP slot has two LED indicators that describe the operational status of the module itself. There is a further single LED indicator per physical interface that describes the status of the line interface. The active LED position is not used on the NHP160.

 

 

 

 

 

 

1

 

NSP-1

ACTIVE

ALARM

SUM

PWR

2

ETH

 

 

 

 

1

 

 

 

ACTIVE

 

 

 

 

 

 

LE

1

3 5

7

9 11 13 15

 

U

 

 

 

 

 

 

 

D

 

 

 

 

 

 

M

O

 

 

 

 

 

 

 

 

 

 

 

 

 

UIP-2

UIP-1

BSP-3

BSP-2

BSP-1

 

E

E

 

C

 

L

 

A

 

U

E

F

 

D

 

 

O

R

 

M

T

 

 

IN

 

D w a y

TM

The following tables describe the status of the NHP160 line interface card based upon the front panel LED status of the card.

MODULE Red LED

MODULE Green LED

Status

(Top)

(Bottom)

 

 

 

 

Off

Off

No power to the card

 

 

 

Off

On

Card operating normally

 

 

 

On

Off

Card failure

 

 

 

On

On

Card initializing during system

 

 

power up

 

 

 

If the card failure sequence is displayed, remove the card and re-insert it into the chassis. If the card failure sequence is still displayed, then replace the card.

Line status (per port):

Port LED

Port State

 

 

off

The card is not configured, or alarm reporting is disabled on the

 

interface

 

 

green

Interface operating normally

 

 

blinking green

Interface performing a diagnostic test

 

 

blinking red

Yellow alarm (RAI)

 

 

red

Interface failure (LOS, OOF, AIS)

 

 

2-20

BROADway - Release 4.00

Page 36
Image 36