Carrier Access 770-0125-AB Installing the NSP101 Control Card, Alarm Output Reporting

Models: 770-0125-AB

1 96
Download 96 pages 9.24 Kb
Page 29
Image 29

Installation

Installing the NSP101 Control Card

Alarm Output Reporting

During a Critical or Major alarm condition on BROADway, the normally open contact (pin 1) is closed, and the normally closed contact (pin 3) is opened.

During a Minor alarm condition on BROADway, the normally open contact (pin 4) is closed, and the normally closed contact (pin 6) is opened.

Alarm Cut Off (ACO)

The Alarm Cut Off button on the front I/O panel is used to silence the current alarm output. A new alarm will re-activate the alarm closures.

Installing the NSP101 Control Card

The NSP101 control card is the heart of the BROADway system and contains the narrowband switch matrix, the integrated IP router, the network timing synchronization subsystem and the management interface into the BROADway node.

BROADway always requires at least one NSP101 card to operate. Two NSP101 cards can be installed to provide redundant operation of the system. If a single NSP101 is used it should be installed in the NSP-1 card slot. The second, redundant NSP101 should be installed in the NSP-2 card slot.

NIP RX1

NIP RX2

RX1

RX2

RX3

RX4

CKIN-1 CKIN-2

ETH-1

ETH-2

SCP-1

NIP TX1

NIP TX2

TX1

TX2

TX3

TX4

 

ALARMS

ACO

SCP-2

NSP-2

NSP-1

Insert one or two NSP101 cards

BROADway - Release 4.00

2-13

Page 29
Image 29
Carrier Access 770-0125-AB Installing the NSP101 Control Card, Alarm Output Reporting, Alarm Cut Off ACO