Installing the BSP200 Line Interface Card

If the card failure sequence is displayed, remove the card and re-insert it into the chassis. If the card failure sequence is still displayed, then replace the card.

Line status (per port):

INTERFACE Red LED

INTERFACE Green

Status

(Bottom)

LED (Top)

 

 

 

 

Off

Off

The card is not configured, or

 

 

alarm reporting is disabled on the

 

 

interface

 

 

 

Off

On

Interface operating normally

 

 

 

Off

Blinking

Interface performing a diagnostic

 

 

test

 

 

 

On

Off

Interface failure (LOS, OOF, AIS)

 

 

 

Blinking

Off

Yellow alarm (RAI)

 

 

 

On

On

Interface initializing during system

 

 

power up

 

 

 