Cabling the NIP400

Use the NIP TX1, NIP TX2, NIP RX1, and NIP RX2 25 pair connectors on the front I/O panel to connect the eight NIP400 slots in the BROADway chassis to your punch down blocks or DSX panels. The NIP TX1 and NIP RX1 connectors support slots NIP-1 through NIP-4, and the NIP TX2 and NIP RX2 connectors support slots NIP-5 through NIP-8. If you are using NIP-8 as a redundant card slot, do not cable any interfaces to the NIP-8 slot.

For cable pinouts of NIP TX1, NIP TX2, NIP RX1, and NIP RX2, see NIP400 Connector Pinouts (NIP TX1–RX1, NIP TX2–RX2)on page A-5.

To attach a cable to the 25 pair connectors:

1. Plug in the female amphenol cable to the 25 pair connection NIP TX1.

2. Verify that the c-clips that slip over the right hand side of the four

 

c-clip

connectors are closed to prevent against accidental disconnect.

 

 

 

 

3.Repeat the previous step for NIP TX2, NIP RX1, and NIP RX2.

4.Dress the cables out to the left of the chassis. Connect the other end of the cables to your terminating equipment.

Connect to DSX panels or punch down blocks

NIP RX1

NIP RX2

RX1

RX2

RX3

RX4

CKIN-1 CKIN-2

ETH-1

ETH-2

SCP-1

NIP TX1

NIP TX2

TX1

TX2

TX3

TX4

 

ALARMS

ACO

SCP-2

5.To remove the cable, slide the top right hand corner of the c-clip to the left to enable the cable to be easily removed otherwise damage to the cable can result and the cable might not re-engage.

BROADway - Release 4.00

2-17

Page 33
Image 33
Carrier Access 770-0125-AB installation manual Cabling the NIP400, Clip, Connect to DSX panels or punch down blocks