Carrier Access 770-0125-AB Installing the BSP200 Line Interface Card, BSP200 line terminations

Models: 770-0125-AB

1 96
Download 96 pages 9.24 Kb
Page 37
Image 37

Installation

Installing the BSP200 Line Interface Card

Installing the BSP200 Line Interface Card

BROADway supports up to four BSP200 single port DS3/mapper line interface cards installed in positions BSP-1, BSP-2, BSP-3 and BSP-4. If you plan to support redundant BSP operation, you should preferably install the redundant BSP module in BSP-4. When cabling to other DS3 equipment in an office environment. Follow the design rules for the distance between DS3 terminal equipment and DSX-3 bays and inter-bay patch panels; DS3 signals can be very sensitive to incorrectly wired segments.

BSP200 line terminations

NIP RX1

NIP RX2

RX1

RX2

RX3

RX4

CKIN-1 CKIN-2

ETH-1

ETH-2

SCP-1

NIP TX1

NIP TX2

TX1

TX2

TX3

TX4

 

ALARMS

ACO

SCP-2

BSP-4

BSP-3

BSP-2

BSP-1

Insert the BSP200 card into the chassis. Open the ejector tabs and slide the card into its proper slot until you feel resistance, then push to close the ejector tabs into their locking position against the metal rails. Check that the card is firmly in place by applying pressure to the ejector tabs to seat the card fully into the chassis.

WARNING! WHEN INSTALLING OR REPLACING BROADWAY HARDWARE, ALWAYS ADHERE TO GOOD PRACTICE WITH RESPECT TO ESD PROCEDURESUSE A REGULARLY AND PROPERLY TESTED GROUNDING STRAP.

BROADway - Release 4.00

2-21

Page 37
Image 37
Carrier Access 770-0125-AB installation manual Installing the BSP200 Line Interface Card, BSP200 line terminations